Photonics Source provides 136 categories and 7939 products.
-
TX10 Series Digital Thermometers
Number of Input Channels TX1001: 1 Number of Input Channels TX1002: 1 Number of Input Channels TX1003: 2 Measuring Range Type K TX1001: -200°C to 1372°C Measuring Range Type J TX1001: -200°C to 1000°C -
702915/702916 Current Probes
Bandwidth 702915: DC to 50MHz (-3dB) Bandwidth 702916: DC to 120MHz (-3dB) Rise Time 702915: ≤7ns Rise Time 702916: ≤2.9ns Delay Time 702915: 12ns (typical) -
702915/702916 Current Probes
Bandwidth 702915: DC to 50MHz (-3dB) Bandwidth 702916: DC to 120MHz (-3dB) Rise Time 702915: ≤7ns Rise Time 702916: ≤2.9ns Delay Time 702915: 12ns (typical) -
702915/702916 Current Probes
Bandwidth 702915: DC to 50MHz (-3dB) Bandwidth 702916: DC to 120MHz (-3dB) Rise Time 702915: ≤7ns Rise Time 702916: ≤2.9ns Delay Time 702915: 12ns (typical) -
702915/702916 Current Probes
Frequency Range 702915: DC to 50MHz (-3dB) Frequency Range 702916: DC to 120MHz (-3dB) Rise Time 702915: ≤7ns Rise Time 702916: ≤2.9ns Delay Time 702915: 12ns (typical) -
702915/702916 Current Probes
Bandwidth: DC to 50MHz (-3dB) (702915), DC to 120MHz (-3dB) (702916) Rise Time: ≤7ns (702915), ≤2.9ns (702916) Delay Time: 12ns (typical) Maximum Current: 30Arms Measurement Range: 30A, 5A, 0.5A -
702915/702916 Current Probes
Frequency Range 702915: DC to 50MHz (-3dB) Frequency Range 702916: DC to 120MHz (-3dB) Rise Time 702915: ≤7ns Rise Time 702916: ≤2.9ns Delay Time 702915: 12ns (typical) -
Precision Waveform Measurement Probes
Maximum Input Voltage: 600VDC+ACpeak Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Resistance: 10MΩ Input Capacitance: 13.5pF -
Precision Waveform Measurement Accessories
Frequency Bandwidth (MHz): 10-5000 Maximum Input Voltage (Vpeak): 20-7000 Attenuation Ratio: 10:1, 100:1, 500:1 Input Impedance: 10MΩ, 100kΩ Maximum Input Current (Arms): 0.5-500 -
Precision Waveform Measurement Probes and Accessories
Frequency Bandwidth (MHz): 10-5000 Maximum Input Voltage (Vpeak): 20-7000 Maximum Input Current (Apeak): 0.5-500 Attenuation Ratio: 10:1, 100:1, 500:1 Input Impedance: 10MΩ, 100kΩ -
Precision waveform measurement essentials
Maximum Input Voltage: ±10V(DC+ACpeak) Frequency Range: 900MHz Attenuation Ratio: 1:1 Input Resistance/Capacitance: 450Ω/90.2pF Cable Length: 1.1m -
Precision waveform measurement essentials
Maximum Input Voltage: 1000V(DC+ACpeak) Frequency Range: 900MHz Attenuation Ratio: 10:1 Input Resistance/Capacitance: 4500Ω/90.25pF Total Length: 1.1m -
UWCN3045-200212CA
Input Voltage: AC100V-240V Input Frequency: 50Hz-60Hz Input Power: 101VA Output Voltage 1: DC5V Output Current 1: 3A -
Precision waveform measurement essentials
Frequency Bandwidth: 10MHz-5000MHz Maximum Input Voltage: 20V-7000V Attenuation Ratio: 10:1, 100:1, 500:1 Input Resistance: 10MΩ, 100kΩ Input Capacitance: 10pF-22pF -
Signal Conditioner
Input Voltage Range: 0-10V Output Voltage Range: 0-10V Operating Temperature Range: -40°C to +70°C Signal Type: Analog Supply Voltage: 24V DC -
Precision Waveform Measurement Essentials
Frequency Bandwidth: 10MHz-5000MHz Maximum Input Voltage: 20V-7000V Maximum Input Current: 1mA-500A Input Impedance: 10MΩ-100kΩ Attenuation Ratio: 10:1, 50:1, 100:1, 1000:1 -
Precision Waveform Measurement Essentials
Frequency Bandwidth Passive Probe 701937: 500MHz Maximum Input Voltage Passive Probe 701937: 600Vpeak Attenuation Ratio Passive Probe 701937: 10:1 Input Resistance Passive Probe 701937: 10MΩ Total Length Passive Probe 701937: 1.3m -
Precision waveform measurement essentials
Maximum Input Voltage: 1000V DC+ACpeak Frequency Range: 100MHz Attenuation Ratio: 10:1 Input Resistance/Capacitance: 10MΩ/37.5pF Cable Length: 2.5m -
NA Conversion Adapter Model 735385
Model: 735385-001 Optical Connector: FC-PC (inside the adapter) Mass: Approx. 8g Operating Temperature Range: -5°C to +45°C Storage Temperature Range: -20°C to +60°C -
96095 AC/DC Clamp-on Probe
Measurement Range: AC/DC 0-30A Frequency Range: DC to 100kHz Basic Accuracy: ±1% of reading Output Voltage: 100mV/A Power Supply Voltage: 1.5V (Alkaline dry cell)