Selected
- China
- Inficon
Current Category:
- 3D Scanner
- Beam Profilers
- Conventional Microscopes
- Displacement Gages
- Sensors
- Fiber Inspection Tools
- Fiber Test & Measurement
- Gas Analysis
- Interferometers
- Laser Scanning and Ranging
- LiDAR
- Material Analysis and Forensics
- Measurement Devices
- Metrology Accessories
- Microscope Accessories
- Microscopes
- Optical Cells
- Optical Inspection
- Optical Metrology
- Optical Power Meters
- Optical Spectrum Analyzers
- Optical Surface Profiler
- Optical Wavelength Meters
- Scanners and Rangefinders
- Size Measurement
- Spectrometers
- Terahertz
- Thermal Solutions
- Waveform Generators and Analyzers
- Other
- Probe Station
- Probe Station Accessories
Country:
More
Brand:
More
Photonics Source provides 16 products. Download datasheets, request quotes, and compare function, price, and availability.
-
Transpector MPS and MPH
Sensor Length (vacuum side) MPS100F: 14.3cm(5.63in) Sensor Length (vacuum side) MPS100M: 19.3cm(7.83in) Sensor Length (vacuum side) MPS200F: 14.3cm(5.63in) Sensor Length (vacuum side) MPS200M: 19.3cm(7.83in) Sensor Length (vacuum side) MPH100F: 14.3cm(5.63in) -
Hydrocarbon Detector (HCD)
Operating Pressure Range: sub 1Torr - 1ATM Limit of Detection: ppm to ppb based on operating pressure Operating Temperature Range: -25°C to 180°C Sensitivity (High Emission): ≥2E-5Amps/Torr Mounting Flange: Standard KF25; custom options available -
Transpector XPR 3+
Mass Range: 1–100amu Resolution (per 1993 AVS recommended practice): <1@10%measuredatmass4,20,28and40 Mass Filter Type: Quadrupole Detector Type: Off-axisFCandmicrochannelplateEM Mass Position Stability: <0.1amuover24hours -
Transpector MPS/MPH
Sensor Length (vacuum side) MPS100F: 14.3cm(5.63in) Sensor Length (vacuum side) MPS100M: 19.3cm(7.83in) Sensor Length (vacuum side) MPS200F: 14.3cm(5.63in) Sensor Length (vacuum side) MPS200M: 19.3cm(7.83in) Sensor Length (vacuum side) MPH100F: 14.3cm(5.63in) -
Transpector CPX Residual Gas Analyzer
Maximum Mass Range: 100amu, 200amu, 300amu Total Pressure Range: 1×10^-8 to 5×10^-2mbar Ion Source Type: Single Filament Closed Ion Source Total Pressure Source Operating Pressure: 1×10^-8 to 5×10^-2mbar Maximum Total Pressure: 5×10^-2mbar -
Transpector APX Residual Gas Analyzer
Maximum Pressure: 1×10-3mbar Total Pressure: ≤5×10-7mbar Minimum Usable Operating Pressure: 1×10-3mbar Maximum Operating Pressure: 1×10-3mbar Sensitivity (High Emission): >1×10-6A/mbar -
QMG 800 Analytical Mass Spectrometer
Mass Range QMA 430: 1-300AMU Mass Range QMA 400: 1-512AMU Rod Material QMA 430: Stainless Steel Rod Material QMA 400: Molybdenum Maximum Operating Pressure: 1E-5mbar (1E-3Pa) -
Transpector APX Residual Gas Analyzer
Maximum Pressure: 1to100mbar, 1to200mbar, 1to1500mbar Ion Source Type: Closed Ion Source Total Pressure Range: 5E-10to1E-3mbar, 5E-10to1E-3mbar, 5E-10to1E-3mbar Minimum Usable Operating Pressure: 1E-7mbar, 1E-7mbar, 1E-7mbar Maximum Operating Pressure: 1E-3mbar, 1E-3mbar, 1E-3mbar -
Quantus HP100 Gas Analyzer
Technology: Optical Emission Spectroscopy with integrated microwave microplasma Technology: spectrometer Technology: and RF power supply Spectrometer Performance: 200–850nm wavelengths (UV-VIS) 16-bit full-scale resolution, 3648 pixels Optical Resolution: 1.34nm -
Micro GC Fusion
Detection Limit: 1ppm Input Pressure: ≤1000psi Display: 6in multi-touch LED backlit Network Protocol: IEEE 802.11a/g/n Wi-Fi Modular Design: Plug-n-Play GC module with temperature programming capability -
Quantus LP100+ Gas Analyzer
Technology: Optical Emission Spectroscopy using proprietary and integrated ICP microplasma Technology: spectrometer Technology: and RF power supply Spectrometer Performance: 200–850nm wavelengths (UV-VIS) 16-bit full-scale resolution, 3648 pixels Exposure Time: Minimum of 1ms -
HAPSITE ER Chemical Identification System
Operating Temperature: 5–45°C Dimensions (L×W×H): 46×43×18cm (18×17×7in) Weight: Approximately 19kg (42lb) with battery Power Supply: Rechargeable NiMH battery pack or AC converter Battery Life: 2–3hrs -
HAPSITE CDT Chemical Identification System
Dimensions (L×W×H): 51.3×50.4×20.0cm Weight: 19.2kg with 1 battery Operating Temperature: 0-45°C Operating Humidity: 5-95% relative humidity Power: 24VDC Ext Power, 28VDC Li-Ion Battery -
FLUE-Mate Combustion Analyzer
Includes: FLUE-Mate, Flue gas probe with 5ft (1.5m) dual hose, Manometer pressure hose, Water trap, AC wall charger, Carrying case Power source: Lithium-ion battery (rechargeable) Battery Life: 8hours Weight: 0.77lb (349g) Warranty: Two-year over-the-counter -
CMS5000 Monitoring System
Power Requirement: 120-240VAC Weight: 55.1lbs (25kg) without sampling vessel Dimensions: 16.9"x32.7"x10.2" (43cmx83cmx26cm) Operating Temperature: 5-45°C, 95% RH (non-condensing) Ionization Source: 2.4mCi Ni-63 Micro Argon Ionization Detector (MAID) -
Augent™ OPG550 Optical Plasma Vacuum Gauge
Measurement System: Cold Cathode according inverted magnetron principle and Thermal conductivity according Pirani principle Measurement Range N2 (mbar): 1×10⁻⁷...5 Measurement Range N2 (Torr): (7.6×10⁻⁸...3.8) Detection limit 25 liter chamber O2 leaks in pressure rise method (mTorr/min): >=0.3 O2 leaks during pump down from atmosphere with N2 backfill (mTorr/min): >=1