Selected
- China
Current Category:
- 3D Scanner
- Beam Profilers
- Conventional Microscopes
- Displacement Gages
- Sensors
- Fiber Inspection Tools
- Fiber Test & Measurement
- Gas Analysis
- Interferometers
- Laser Scanning and Ranging
- LiDAR
- Material Analysis and Forensics
- Measurement Devices
- Metrology Accessories
- Microscope Accessories
- Microscopes
- Optical Cells
- Optical Inspection
- Optical Metrology
- Optical Power Meters
- Optical Spectrum Analyzers
- Optical Surface Profiler
- Optical Wavelength Meters
- Scanners and Rangefinders
- Size Measurement
- Spectrometers
- Terahertz
- Thermal Solutions
- Waveform Generators and Analyzers
- Other
- Probe Station
- Probe Station Accessories
Country:
More
Brand:
More
Photonics Source provides 47 products. Download datasheets, request quotes, and compare function, price, and availability.
-
AQ7800 Ambient Air Non-Methane Total Hydrocarbons Continuous Monitoring System (Direct Measurement Method)
Detection Method: GC-FID Measurement Method: 直测法(Direct Measurement) Measured Components: 甲烷、非甲烷总烃(CH4、NMHC) Detection Limit: ≤1ppbC Latest Standard Detection Limit Requirement: 20ppbC -
AQ7100 Micro Ambient Air Quality Monitoring System
Monitoring Factors: SO2、NO2、CO、O3、PM2.5、PM10 Meteorological Parameters: 风速、风向、温度、湿度、大气压 Monitoring Network Mode: 高密度网格化布局、群防式协同监测网络 Data Application: 污染来源追踪、预警预报、大数据分析 Model Number: AQ7100 -
Transpector MPS and MPH
Sensor Length (vacuum side) MPS100F: 14.3cm(5.63in) Sensor Length (vacuum side) MPS100M: 19.3cm(7.83in) Sensor Length (vacuum side) MPS200F: 14.3cm(5.63in) Sensor Length (vacuum side) MPS200M: 19.3cm(7.83in) Sensor Length (vacuum side) MPH100F: 14.3cm(5.63in) -
Hydrocarbon Detector (HCD)
Operating Pressure Range: sub 1Torr - 1ATM Limit of Detection: ppm to ppb based on operating pressure Operating Temperature Range: -25°C to 180°C Sensitivity (High Emission): ≥2E-5Amps/Torr Mounting Flange: Standard KF25; custom options available -
Transpector XPR 3+
Mass Range: 1–100amu Resolution (per 1993 AVS recommended practice): <1@10%measuredatmass4,20,28and40 Mass Filter Type: Quadrupole Detector Type: Off-axisFCandmicrochannelplateEM Mass Position Stability: <0.1amuover24hours -
Transpector MPS/MPH
Sensor Length (vacuum side) MPS100F: 14.3cm(5.63in) Sensor Length (vacuum side) MPS100M: 19.3cm(7.83in) Sensor Length (vacuum side) MPS200F: 14.3cm(5.63in) Sensor Length (vacuum side) MPS200M: 19.3cm(7.83in) Sensor Length (vacuum side) MPH100F: 14.3cm(5.63in) -
Transpector CPX Residual Gas Analyzer
Maximum Mass Range: 100amu, 200amu, 300amu Total Pressure Range: 1×10^-8 to 5×10^-2mbar Ion Source Type: Single Filament Closed Ion Source Total Pressure Source Operating Pressure: 1×10^-8 to 5×10^-2mbar Maximum Total Pressure: 5×10^-2mbar -
Transpector APX Residual Gas Analyzer
Maximum Pressure: 1×10-3mbar Total Pressure: ≤5×10-7mbar Minimum Usable Operating Pressure: 1×10-3mbar Maximum Operating Pressure: 1×10-3mbar Sensitivity (High Emission): >1×10-6A/mbar