Photonics Source provides 136 categories and 7939 products.
-
TITAN™ RF Probes
Characteristic Impedance: 50Ω Frequency Range: DC to 110GHz Insertion Loss: <1.2dB Return Loss: >14dB DC Current: ≤1A -
Prober Shuttle Platform
Diameter: 140mm Height: 10mm Substage Travel X and Y: 9mm Substage Travel Z: 0.7mm Prober Travel X: 4.5mm -
MPI MicroPositioner
Feature Resolution: <4μm Travel range (X/Y/Z): 10/10/10mm Screw resolution (X/Y/Z): 500/500/500μm Mounting: Magnetic Base stage size: 25mm -
MPI MicroPositioner
Feature Resolution: <2μm Travel Range (X/Y/Z) MP25: 10/10/10mm Travel Range (X/Y/Z) MP40: 13/13/13mm Travel Range (X/Y/Z) MP50: 13/13/13mm Travel Range (X/Y/Z) MP60: 13/13/13mm -
Unknown
Dimensions: Unknown Connector Type: Unknown Operating Temperature: Unknown Storage Temperature: Unknown Power Requirements: Unknown -
Unknown
Circuit Board Dimensions: Unknown Processor Type: Unknown Operating Temperature Range: Unknown Power Requirements: Unknown Interface Type: Unknown -
Coax Probe, Triax Probe, Kelvin Probe, Kelvin HT Probe
Max Voltage: 500V Temperature range: -60°C to 300°C Leakage Current Coax Probe: <0.8pA Leakage Current Triax Probe: ≤±20fA Leakage Current Kelvin Probe: ≤±10fA -
AC3 Controller
Temperature range: -65°C to +200°C Temperature Stability: ±0.1°C Cooling Capacity: High-efficiency air cooling system Control Accuracy: High precision Display: Touchscreen interface -
一维磁场探针台
Probe Station Dimensions: 520×290×197mm Magnetic Field Range: 0-1T Probe Movement Range: ±100mm Display Screen Size: 120.6mm Worktable Diameter: 86mm -
Cryogenic Probe Station
Temperature Range 4K Cryogenic Refrigerator: <4K-350K Sample Stage Temperature 4K Cryogenic Refrigerator: 5K-350K Temperature Range 10K Cryogenic Refrigerator: <10K-350K Sample Stage Temperature 10K Cryogenic Refrigerator: 10K-350K Optional 700K Component: 20K-700K -
Optical Measurement System
Optical Resolution: 0.01nm Measurement Range: 400-700nm Measurement Accuracy: ±0.1nm Light Source Type: LED Operating Temperature: 0-40°C -
MPS-C300 Magnetic Probe Station
Magnetic Field Strength: 0-3000G Magnetic Field Uniformity: ±0.5% Sample Size: Up to 2 inches Temperature range: -20°C to 100°C Control Accuracy: ±0.1G -
Advanced Measurement System
Maximum Temperature (°C): 500 Time Range (s): 0-1500 Current Range (A): 1-27 Resolution (A/div): 2.00 Time Resolution (s/div): 200m/div -
光电测试系统
Testing Accuracy: ±0.01 Testing Range: 0-1000nm Data Acquisition Speed: 100ms Operating Temperature: 10-40°C Power Requirements: 220V, 50Hz -
螺线管磁场分布仪
Dimensions: 220mm×125mm×132.5mm Magnetic Field Strength: 300Gs-600Gs Distance Range: -100mm to 100mm Power Interface: Standard dual interface -
LH Series Electromagnets
Magnet Model: LH30, LH60, LH100, LH130, LH180 Pole Diameter: 30mm, 60mm, 100mm, 130mm, 180mm Pole Face Diameter: 25mm, 35mm, 55mm, 65mm, 80mm Magnetic Gap Adjustment: Dual-direction continuous adjustment Gap Range: 0~35mm, 0~65mm, 0~65mm, 0~110mm, 0~130mm -
Cryogenic Probe Station
Temperature Range 4K闭循环制冷机样品台温度: <4K-350K Temperature Range 10K闭循环制冷机样品台温度: <10K-350K Temperature Stability: ±0.1K Vacuum Chamber Material: Aluminum Vacuum Chamber Probe Count: 6 -
Cryocon26C Temperature Control System
Vacuum Time (<1Pa) 4升机械泵: ~30分钟 Vacuum Time (<1Pa) 分子泵组: ~8分钟 Cooling Time (Room Temperature to Minimum Low Temperature): <30分钟 Temperature Controller: Cryocon26C Accuracy: 1mk -
MPI TS3000
Chuck XY Stage Travel Range: 310mm×310mm Chuck XY Stage Resolution: 0.5μm Chuck XY Stage Accuracy: ±2.0μm Chuck XY Stage Repeatability: ±1.0μm Chuck XY Stage Speed: 10mm/sec to 50mm/sec -
MPI TS3000-SE
Travel Range (XY): 310mm×310mm Resolution (XY): 0.5μm Accuracy (XY): ±2.0μm Repeatability (XY): ±1.0μm Travel Range (Z): 30mm