Selected
- China
- Ybsemi-Solution
Current Category:
- 3D Scanner
- Beam Profilers
- Conventional Microscopes
- Displacement Gages
- Sensors
- Fiber Inspection Tools
- Fiber Test & Measurement
- Gas Analysis
- Interferometers
- Laser Scanning and Ranging
- LiDAR
- Material Analysis and Forensics
- Measurement Devices
- Metrology Accessories
- Microscope Accessories
- Microscopes
- Optical Cells
- Optical Inspection
- Optical Metrology
- Optical Power Meters
- Optical Spectrum Analyzers
- Optical Surface Profiler
- Optical Wavelength Meters
- Scanners and Rangefinders
- Size Measurement
- Spectrometers
- Terahertz
- Thermal Solutions
- Waveform Generators and Analyzers
- Other
- Probe Station
- Probe Station Accessories
Brand:
Photonics Source provides 37 products. Download datasheets, request quotes, and compare function, price, and availability.
-
TS3500-SE
Chuck XY Stage Travel Range: 310mm×530mm Resolution: 0.0001° (0.24μm @ 300mm edge) Accuracy: <2.0μm Repeatability: <1.0μm XY Stage Drive: Closed-loop high precision stepper motors -
MPI TS200-HP
Probe Station Dimensions: 900×1050×1930mm Weight: ~500kg Chuck XY Stage Travel Range: 225×260mm Fine Travel Range: 25×25mm Fine Travel Resolution: <1.0μm@500μm/rev -
TS150 Manual Probe System
Total Travel Range: 180x230mm (7.1x9.1in) Fine Travel Range: 25x25mm fine micrometer control Fine Travel Resolution: <1.0μm (0.04mils)@500μm/rev Planarity: <10μm Theta Travel (Standard): 360° -
Prober Shuttle Platform
Diameter: 140mm Height: 10mm Substage Travel X and Y: 9mm Substage Travel Z: 0.7mm Prober Travel X: 4.5mm -
一维磁场探针台
Probe Station Dimensions: 520×290×197mm Magnetic Field Range: 0-1T Probe Movement Range: ±100mm Display Screen Size: 120.6mm Worktable Diameter: 86mm -
Cryogenic Probe Station
Temperature Range 4K Cryogenic Refrigerator: <4K-350K Sample Stage Temperature 4K Cryogenic Refrigerator: 5K-350K Temperature Range 10K Cryogenic Refrigerator: <10K-350K Sample Stage Temperature 10K Cryogenic Refrigerator: 10K-350K Optional 700K Component: 20K-700K -
Optical Measurement System
Optical Resolution: 0.01nm Measurement Range: 400-700nm Measurement Accuracy: ±0.1nm Light Source Type: LED Operating Temperature: 0-40°C -
MPS-C300 Magnetic Probe Station
Magnetic Field Strength: 0-3000G Magnetic Field Uniformity: ±0.5% Sample Size: Up to 2 inches Temperature range: -20°C to 100°C Control Accuracy: ±0.1G -
Advanced Measurement System
Maximum Temperature (°C): 500 Time Range (s): 0-1500 Current Range (A): 1-27 Resolution (A/div): 2.00 Time Resolution (s/div): 200m/div -
光电测试系统
Testing Accuracy: ±0.01 Testing Range: 0-1000nm Data Acquisition Speed: 100ms Operating Temperature: 10-40°C Power Requirements: 220V, 50Hz -
螺线管磁场分布仪
Dimensions: 220mm×125mm×132.5mm Magnetic Field Strength: 300Gs-600Gs Distance Range: -100mm to 100mm Power Interface: Standard dual interface -
LH Series Electromagnets
Magnet Model: LH30, LH60, LH100, LH130, LH180 Pole Diameter: 30mm, 60mm, 100mm, 130mm, 180mm Pole Face Diameter: 25mm, 35mm, 55mm, 65mm, 80mm Magnetic Gap Adjustment: Dual-direction continuous adjustment Gap Range: 0~35mm, 0~65mm, 0~65mm, 0~110mm, 0~130mm -
Cryogenic Probe Station
Temperature Range 4K闭循环制冷机样品台温度: <4K-350K Temperature Range 10K闭循环制冷机样品台温度: <10K-350K Temperature Stability: ±0.1K Vacuum Chamber Material: Aluminum Vacuum Chamber Probe Count: 6 -
Cryocon26C Temperature Control System
Vacuum Time (<1Pa) 4升机械泵: ~30分钟 Vacuum Time (<1Pa) 分子泵组: ~8分钟 Cooling Time (Room Temperature to Minimum Low Temperature): <30分钟 Temperature Controller: Cryocon26C Accuracy: 1mk -
MPI TS3000
Chuck XY Stage Travel Range: 310mm×310mm Chuck XY Stage Resolution: 0.5μm Chuck XY Stage Accuracy: ±2.0μm Chuck XY Stage Repeatability: ±1.0μm Chuck XY Stage Speed: 10mm/sec to 50mm/sec -
MPI TS3000-SE
Travel Range (XY): 310mm×310mm Resolution (XY): 0.5μm Accuracy (XY): ±2.0μm Repeatability (XY): ±1.0μm Travel Range (Z): 30mm -
Unknown
Dimensions: 621x621 Center Hole Diameter: 95 Heat Dissipation Holes: Present Cooling Fans: 4 units Mounting Holes: Multiple -
TS3000-HP
Chuck Dimensions: 310 mm x 335 mm Chuck Resolution: 0.5 μm Chuck Accuracy: ±2.0 μm Chuck Speed: 50 mm/sec Chuck Z-Axis Travel: 30 mm -
TS300-SE Manual Probe System
Probe Station Dimensions (W×D×H): 1190×1180×1590mm Probe Station Weight: ~465kg XY Stage Travel Range: 325×325mm XY Stage Fine Travel Resolution: <1.0μm@500μm/rev XY Stage Planarity: <10μm -
MPI TS2500-SE
Chuck XY Stage Travel Range: 220mm×490mm (8.66×19.29in) Chuck XY Stage Resolution: 0.2μm Chuck XY Stage Accuracy: <2.0μm (0.08mils) Chuck XY Stage Repeatability: <1μm Chuck XY Stage Drive: Closed-loop high precision stepper motors