Photonics Source provides 136 categories and 7939 products.
-
AP29ECO Sampling Unit
Sensitivity: 0.5ppm H₂; 3×10⁻⁶mbarl/s Power Supply: 24V DC from Sensistor Sentrac leak detector Calibration Gas: Fresh air without H₂ contamination Ambient Temperature Range: 10°C to 50°C Dimensions: 92mm×185mm×260mm -
Robotic Leak Detection System
Detection Accuracy: High Detection Speed: Fast Robot Type: Articulated Sensor Type: Advanced leak detection sensors Power Requirements: Standard industrial power supply -
Unknown
Analysis Accuracy: High Measurement Range: Wide Display: Digital touchscreen Power Supply: AC/DC -
Thermal Desorber
Heating Temperature Range: Ambient to 400°C Sample Tube Size: 6mm or 1/4 inch Heating Time: Adjustable Cooling Time: Adjustable Power Requirements: 110-240V, 50/60Hz -
Micro GC Fusion® External Sample Conditioner
ESC Sample Inlet Connection: 1/4in.Swagelok®femalequickconnect Sample Output Temp to Micro GC Fusion: >50°C(122°F) Maximum Sample Pressure: 5516kPa(800psi) Minimum Sample Pressure: 14kPa(2psi) Sample Output Pressure to Micro GC Fusion: 0-172kPa(0-25psi) -
TSP Leak Detector
Detection Sensitivity: High Operating Temperature Range: 0°C to 50°C Power Requirements: 110-240V AC Weight: 1.5kg Dimensions: 150mm x 100mm x 80mm -
SMART-Spray, I-BOOST, SPRAY-Check
Selectable Flow Rate: S=12sccm, M=70sccm, L=250sccm, XL=1100sccm HeliCan Spray Count 50ml: S>600, M>110, L>30 HeliCan Spray Count 405ml: S>5000, M>900, L>260, XL>50 Single Spray Duration: 1.0s-9.9s Battery Type: Li-Ion, 3.63V, 3.35Ah, 12.16Wh -
INFICON Leak Detector
Detection Sensitivity: 1x10^-7 mbar·l/s Response Time: <1s Operating Temperature Range: 0°C to 50°C Power Requirements: 100-240V AC, 50/60Hz Weight: 5kg -
Unknown
Housing Material: Stainless Steel Fiber Type: Single-mode or Multi-mode Operating Temperature: -40°C to +85°C Connector Type: FC/PC, FC/APC, or custom Wavelength Range: 1260nm-1650nm -
Micro GC Fusion
Analysis Time: <2 minutes Detection Range: ppm to percent levels Operating Temperature: 5°C to 45°C Dimensions: 30cm x 20cm x 10cm Weight: 5kg -
1 in. (25.4 mm) Diameter Research Crystals
Frequencies: 5MHz and 9MHz Frequency Range: 4.976–5.020MHz, 8.976–9.036MHz Resistance: 5MHz, ~10Ohms; 9MHz, ~7Ohms Crystal Diameter: 1in. (25.4mm) Crystal Contour: Plano-Plano -
Zevision IMC300
Crystal Frequency Range: 6.0 to 4.5MHz Frequency Resolution: 0.00056Hz @6MHz Frequency Accuracy: ±2.5ppm to 50°C Measurement Rate: 10Hz Thickness and Rate Resolution: ±0.008Å and ±0.08Å/s -
HAPSITE ER
Analysis Time: <10 minutes Detection Limit: ppb levels Weight: <15kg Dimensions: 30cm x 40cm x 25cm Battery Life: >8 hours -
SQM-160 Multi-Film Rate/Thickness Monitor
Sensor Inputs: Standard: two; optional: six Measurement Frequency Range: 6.5 to 10MHz (adjustable) Frequency Resolution: Standard: ±0.30Hz @6MHz; High resolution option: ±0.03Hz @6MHz Thickness and Rate Resolution/Measurement: Standard: ±0.37Å; High resolution option: ±0.037Å Measurement Interval: 0.10 to 2.0s (adjustable) -
STM-2 USB Thin Film Thickness / Rate Deposition Monitor
Compatible sensors: Non-shuttered single QCM sensor Sensor input: One Sensor input: female BNC Measurement Frequency Range: 6.0 to 5.0 MHz (fixed) Frequency Resolution: ±0.03 Hz at 6 MHz -
750-7020-G5 Sensor
Maximum temperature: 200°C Sensor Head Size (Maximum Envelope): 23.9mm O.D. x 28.9mm (0.94in O.D. x 1.14in) Mounting feedthrough: KF25 flange Body and Holder Materials: 304 stainless steel Spring Materials: Au plated BeCu -
IQM-233 Thin Film Deposition Controller Card
Number of Sensor Inputs: 3 Sensor Connectors: SMA - Includes one SMA/BNC adapter Measurement Frequency Range: 6.1 to 4.0MHz (adjustable) Frequency Resolution: ±0.10Hz @ 6MHz Thickness and Rate Resolution/Measurement: ±0.12Å -
SQC-310 Thin Film Deposition Controller
Sensor Inputs: two (four optional) Measurement Frequency Range: 6.5 to 10MHz (adjustable) Frequency Resolution: ±0.012Hz at 6MHz Thickness and Rate Resolution/Measurement: ±0.015Å Measurement Interval: 0.10 to 1.0s (adjustable) -
IC6 Thin Film Deposition Controller
Frequency Resolution: ±0.0035Hz@6MHz Thickness and Rate Resolution/Measurement: ±0.00433Å Measurement Frequency Range: 6.0 to 4.5MHz (fixed) Thickness Accuracy: 0.5% Measurement Interval: 0.1s -
IMM-100 Thin Film Deposition Monitor
Sensor Inputs: One Sensor Inputs: female BNC Measurement Frequency Range: 6.0 to 4.5MHz (fixed) Frequency Resolution: ±0.0035Hz @ 6MHz Measurement Interval: 0.1s