All Products

Photonics Source provides 136 categories and 7939 products.

  • PCG55x Standard Vacuum Gauge Other

    PCG55x Standard Vacuum Gauge

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Principle: thermal conductance according to Pirani Accuracy (1×10^-3...100mbar): ±15% of reading Accuracy (5×10^-4...1×10^-3mbar): ±50% of reading Accuracy (1000mbar): ±50% of reading Repeatability (1×10^-3...100mbar): 2% of reading
  • PSG550, PSG552, PSG554 Other

    PSG550, PSG552, PSG554

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Range PSG550: 5×10⁻⁵...1000mbar Measurement Range PSG552: 5×10⁻⁵...1000mbar (3.8×10⁻⁵...750Torr) Measurement Range PSG554: 5×10⁻⁵...1000mbar Accuracy PSG550: ±50% of reading (5×10⁻⁵...1×10⁻³mbar), ±15% of reading (1×10⁻³...100mbar), ±50% of reading (100...1000mbar) Accuracy PSG552: ±50% of reading (5×10⁻⁵...1×10⁻³mbar), ±15% of reading (1×10⁻³...100mbar), ±50% of reading (100...1000mbar)
  • Porter™ CDG020D Other

    Porter™ CDG020D

    China
    Category: Other
    Manufacturer: Inficon
    Accuracy: 1% (3CA3-xxx-xxx), 0.5% (3CA4-xxx-xxx) Temperature Coefficient: 0.02 percent FS/°C Temperature Drift: 0.02 % of reading/°C Resolution: 0.05 percent FS Long-term Stability: 0.5 percent FS/yr
  • PSG010, PSG017, PSG018 Other

    PSG010, PSG017, PSG018

    China
    Category: Other
    Manufacturer: Inficon
    Measurement System: Pirani Measurement Range: 8×10⁻⁴ to 1000 mbar Accuracy PSG010: ±20% of reading in the range of 1×10⁻³ to 10 mbar, ±2× reading in the range of ≤10² mbar Accuracy PSG017: ±10% of reading in the range of 1×10⁻² to 100 mbar, ±2× reading in the range of ≤10² mbar Accuracy PSG018: ±10% of reading in the range of 1×10⁻² to 100 mbar, ±5× reading in the range of ≤10² mbar
  • PPG570 ATM to Medium Vacuum Gauge + ATM Switch Other

    PPG570 ATM to Medium Vacuum Gauge + ATM Switch

    China
    Category: Other
    Manufacturer: Inficon
    Measuring Principle: MEMS Piezo resistive diaphragm Pressure Range: 2...1333mbar Measuring Range: 1×10^-6...1333mbar Accuracy (1100...1333mbar): 0.5% of reading Accuracy (800...1099mbar): 0.25% of reading
  • PPG550 ATM to Medium Vacuum Gauge Other

    PPG550 ATM to Medium Vacuum Gauge

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Principle: MEMS Piezo resistive diaphragm Pressure Range: 2...1333mbar Measuring Range (N2): 1×10⁻⁶...1333mbar Accuracy (1100-1333mbar): 0.5% of reading Accuracy (800-1099mbar): 0.25% of reading
  • PGE500 Other

    PGE500

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Range: 1.3×10⁻⁴–1333mbar, 1×10⁻⁴–1000Torr, 1.3×10⁻²–133000Pa Accuracy: ±10% of reading (1.3×10⁻³–530mbar, 1×10⁻³–400Torr), ±2.5% of reading (530–1333mbar, 400–1000Torr) Repeatability: ±2% of reading Admissible Temperature: Operation: 0–40°C, Storage: -40–70°C, Bakeout: ≤150°C Supply Voltage: +12–+28V(dc)
  • PGE500 DeviceNet™ Other

    PGE500 DeviceNet™

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Range: 1.3×10⁻⁴–1333mbar, 1×10⁻⁴–1000Torr, 1.3×10⁻²–133000Pa Accuracy: ±10% of reading, ±2.5% of reading Repeatability: ±2% of reading Admissible Temperature: Operation: 0–40°C, Storage: -40–70°C, Bakeout: ≤150°C Supply Voltage: +12–+26V(dc)
  • PCG55x Atmospheric to Medium Vacuum Gauge Other

    PCG55x Atmospheric to Medium Vacuum Gauge

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Range (mbar): 5×10⁻⁵…1500 Measurement Range (Torr): 3.8×10⁻⁵…1125 Accuracy 5×10⁻⁴…1×10⁻³ mbar: ±50% of reading Accuracy 1×10⁻³…100 mbar: ±15% of reading Accuracy 100…950 mbar: ±5% of reading
  • PGE300 Pirani Gauge Enhanced Other

    PGE300 Pirani Gauge Enhanced

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Range: 1.3×10⁻⁴–1333mbar, 1×10⁻⁴–1000Torr, 1.3×10⁻²–133000Pa Accuracy: 0.1×10⁻³mbar resolution, ±10% of reading, ±2.5 Repeatability: ±2% of reading Admissible Temperature: Operation: 0–40°C, Storage: -40–70°C, Bakeout: ≤70°C Supply Voltage: +12–+28V(dc)
  • PGE050 Pirani Gauge Enhanced - Passive Other

    PGE050 Pirani Gauge Enhanced - Passive

    China
    Category: Other
    Manufacturer: Inficon
    Measurement System: Pirani, convection-enhanced Measurement Range: 1.3×10⁻⁴ to 1333mbar, 1×10⁻⁴ to 1000Torr, 1.3×10⁻² to 133000Pa Accuracy: 1.3×10⁻⁴ to 1.3×10⁻³mbar: ±0.1×10⁻³mbar, 1.3×10⁻³ to 530mbar: ±10% of reading, 530 to 1333mbar: ±2.5% of reading Repeatability: ±2% of reading Mounting Orientation: Recommended horizontal
  • PGD500 Other

    PGD500

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Channels: 1 (PSG5xx, PCG55x or MPG series) Display: LCD Range: 5×10⁻⁷...1.5×10⁻³Pa, 5×10⁻²...1500mbar Measurement Rate: 30/s Measurement Unit: Pa
  • PBR 260 Other

    PBR 260

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Range: 5×10⁻¹⁰–1000mbar Bakeout Temperature: 150°C Accuracy: 10⁻⁸–10⁻²mbar ±15% of reading Repeatability: 5% of reading Supply Voltage: 20–28V(dc)
  • Modul1000 Other

    Modul1000

    China
    Category: Other
    Manufacturer: Inficon
    Detection Sensitivity: ≤1×10^-7 mbar·l/s Test Gas: Helium Test Gas: Hydrogen Operating Temperature: 5°C to 45°C Power Requirements: 100-240V AC, 50/60Hz
  • MAG470 Inverted Magnetron Gauge Other

    MAG470 Inverted Magnetron Gauge

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Range (air, N₂): 5×10⁻¹¹ mbar to 1×10⁻² mbar (3.8×10⁻¹¹ Torr to 7.5×10⁻³ Torr) Accuracy (N₂): ±30% of reading Repeatability (N₂): ±5% of reading Mounting Orientation: any Admissible Pressure (absolute): ≤10bar (limited to inert gases)
  • MPG40x High Vacuum Gauge Other

    MPG40x High Vacuum Gauge

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Range (Air, N₂): 5×10⁻⁹...1000mbar Measurement Range (Air, N₂) Torr: 3.8×10⁻⁹...760 Accuracy (N₂): 1×10⁻⁸...100mbar ±30% Repeatability: 1×10⁻⁸...100mbar ±5% Installation Position: any
  • MAG084 Other

    MAG084

    China
    Category: Other
    Manufacturer: Inficon
    Measurement System: cold cathode ionization (inverted magnetron principle) Display Range (Air N2): 5×10^-9mbar to 1×10^-2mbar Measurement Range (Air N2): 1×10^-8mbar to 5×10^-3mbar Accuracy (Air N2): 30% of reading Repeatability (typical): 5% of reading
  • MAG050, MAG060, MAG070 Other

    MAG050, MAG060, MAG070

    China
    Category: Other
    Manufacturer: Inficon
    Measurement System: Cold cathode ionization (inverted magnetron principle) Measurement Range MAG050: 2×10⁻²...5×10⁻³ mbar Measurement Range MAG060: 1×10⁻¹⁰...5×10⁻³ mbar Measurement Range MAG070: 1×10⁻¹¹...5×10⁻³ mbar Accuracy: 30% of reading
  • LDS3000 Other

    LDS3000

    China
    Category: Other
    Manufacturer: Inficon
    Detection Method: Helium leak detection Sensitivity: ≤1×10^-12 mbar·l/s Testing Range: 1×10^-12 to 1×10^-1 mbar·l/s Response Time: ≤1 second Operating Temperature: 5°C to 45°C
  • LDS3000 Other

    LDS3000

    China
    Category: Other
    Manufacturer: Inficon
    Detection Sensitivity: ≤5×10^-12mbar·l/s Test Gas: Helium Test Gas: Hydrogen Operating Temperature: 10°C-45°C Power Requirements: 100-240VAC, 50/60Hz
AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →