Photonics Source provides 136 categories and 7939 products.
-
CA71 Portable Process Calibrator
Voltage Measurement Range: 0-1100V Current Measurement Range: 0-24mA Resistance Measurement Range: 0-3200Ω Thermocouple Measurement Range: -200°C to 1800°C Frequency Measurement Range: 0.01Hz to 110kHz -
Precision Waveform Measurement Probes
Maximum Input Voltage: 600VDC+ACpeak Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Resistance/Capacitance: 10MΩ/13.5pF Total Length: 1.5m -
Precision waveform measurement essentials
Maximum Input Voltage: 600VDC+ACpeak Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Resistance/Capacitance: 10MΩ/13.5pF Total Length: 1.5m -
Precision Waveform Measurement Essentials
Maximum Input Voltage: 600VDC+ACpeak Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Capacitance: 13.5pF Total Length: 1.5m -
Precision waveform measurement probes and accessories
Maximum Input Voltage: 600VDC+ACpeak Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Resistance/Capacitance: 10MΩ/13.5pF Cable Length: 1.5m -
Voltage Probes and Accessories
Frequency Bandwidth: 10MHz-5GHz Maximum Input Voltage: 20Vpeak-7000Vpeak Attenuation Ratio: 10:1, 50:1, 100:1 Input Resistance: 10MΩ Input Capacitance: 10pF-22pF -
Precision waveform measurement accessories
Frequency Bandwidth: 10MHz-5GHz Maximum Input Voltage: 20V-7000V Maximum Input Current: 0.5A-500A Attenuation Ratio: 10:1-1000:1 Input Impedance: 10MΩ-100kΩ -
Precision Waveform Measurement Essentials - Probes and Accessories for Oscilloscopes
Frequency Bandwidth (MHz) 701937: 500 Maximum Input Voltage (Vpeak) 701937: 600 Attenuation Ratio 701937: 10:1 Input Resistance 701937: 10MΩ Input Capacitance 701937: 13.5pF -
GX90NW Network Module
Communication Method: PROFINET PROFINET Device Type: PROFINET IO device Conformance Class: B Supported Communication Types: Periodic and aperiodic communication Maximum Communication Distance: 100m -
Precision waveform measurement essentials
Maximum Input Voltage: 600VDC+ACpeak Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Capacitance: 13.5pF Cable Length: 1.5m -
Power Consumption Measuring Software
Supported Operating Systems: Windows 7, Windows 8.1, Windows 10 (32-bit and 64-bit) CPU: Pentium 4 1.5GHz or higher (recommended) Memory: 512MB or more (recommended) HDD: 500MB or more of free space Communication Ports: GP-IB, RS-232, Ethernet, USB -
ScopeCorder Plug-in Modules
Sample Rate: 200MS/s Resolution: 14bit Bandwidth: 40MHz Number of Channels: 2 Isolation: Isolated -
Model 257875 RJ Sensor
Measurement Range: -20°C to +60°C Accuracy: ±0.3°C Cord Length: Approx.1.95m Compatible Instruments: 2553A or 2560A Excitation Current: Approx.1mA -
Unknown
Housing Material: Metal Dimensions: 100mm x 50mm x 50mm Weight: 500g Power Requirements: DC 12V Operating Temperature: 0°C to 50°C -
SLM-200 Spatial Light Modulator
Wavelength Range: 450-1600nm Reflectivity: Typ.>0.990 Wavefront Error: Typ.<0.001π rad. Optical Power Density: Typ.10MW/cm² Water Cooling Flow: 1L/min -
CWDM-15 3 Port Add/Drop Module
Operating Temperature (°C): -10 to 70 Insertion Loss (Transmission) (dB): ≤0.8 Insertion Loss (Reflection) (dB): ≤0.4 Flatness (dB): ≤0.4 Adjacent Channel Isolation (Transmission) (dB): ≥30 -
MTF-FT
Insertion Loss (BOL): ≤3.5dB BW @3dB: 300-390GHz BW @20dB: 535-745GHz Out of band extinction ratio: ≥40dB Optical Return Loss: ≥35dB -
Unknown
Dimensions: Small-sized, comparable to a coin Connector Type: Pin-based Housing Material: Metal and plastic composite Applicable Voltage: Unknown Operating Temperature Range: Unknown -
HSL-20
Main Scan Rate (kHz): 50 or 100±0.1 Maximum Optical Output Power (mW): ≤40 Center Wavelength (nm): 1280-1340 Scan Range (nm): ≥105 Coherence Length (mm): ≥16