Other

Selected
  • China
  • Inficon

Photonics Source provides 95 products. Download datasheets, request quotes, and compare function, price, and availability.

  • XL3000flex Other

    XL3000flex

    China
    Category: Other
    Manufacturer: Inficon
    Minimum Detectable Leak Rate (KnL) for Helium/Hydrogen High Flow: 2×10⁻⁷mbarl/s Minimum Detectable Leak Rate (KnL) for Helium/Hydrogen Low Flow: 2×10⁻⁷mbarl/s Gas Flow High Flow: 3000sccm Gas Flow Low Flow: 300sccm Response Time (High Flow and Low Flow): <1s
  • Whisper Ultrasonic Leak Detector Other

    Whisper Ultrasonic Leak Detector

    China
    Category: Other
    Manufacturer: Inficon
    Product Name: Whisper Ultrasonic Leak Detector Power Supply: Two D-type alkaline batteries Battery Life: 165 hours (with laser pointer off), 115 hours (with laser pointer on) Weight: 482g Certifications: A2L certified, CE
  • VSD200 Differential Switch Other

    VSD200 Differential Switch

    China
    Category: Other
    Manufacturer: Inficon
    Type: -100...+50mbar, -100...+50Torr Differential Pressure Range: -100...+50mbar, -100...+50Torr Differential Pressure Range (1): -100...+50mbar, -100...+50Torr Setpoint Range: -99...+46mbar, -99...+46Torr Capacity Pressure: 2bar (absolute)
  • VSC150A Absolute Switch, Passive Other

    VSC150A Absolute Switch, Passive

    China
    Category: Other
    Manufacturer: Inficon
    Switching Range (mbar): 0.5...2000 Response Sensitivity (mbar): 0.1 Overload Limit (mbar): 3000 Switch Hysteresis (mbar): 0.5 Operating Temperature (°C): 5...90
  • VSA200 Absolute Switch Other

    VSA200 Absolute Switch

    China
    Category: Other
    Manufacturer: Inficon
    Full Scale (mbar absolute): 1100 Full Scale (Torr absolute): 1000 Setpoint Range (mbar): 30...1060 Setpoint Range (Torr): 20...970 Capacity Pressure (bar absolute): 5
  • VSA100A Other

    VSA100A

    China
    Category: Other
    Manufacturer: Inficon
    Opening Pressure (mbar): 6±2 (below atmosphere) Reverse Opening (mbar): 3±2 (below atmosphere) Operating Pressure (bar): <2 Helium Permeation (mbar·L/s): <10⁻⁶ Leak Rate (mbar·L/s): <5×10⁻⁸
  • VGC094 Vacuum Gauge Controller Other

    VGC094 Vacuum Gauge Controller

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Channels: 4 Display: LCD Display: LED backlight Measurement rate: 100s⁻¹ Display Rate: 10s⁻¹
  • VGC50x Vacuum Gauge Controller Other

    VGC50x Vacuum Gauge Controller

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Channels VGC501: 1 Measurement Channels VGC502: 2 Measurement Channels VGC503: 3 Display: LCD Display: LED backlight
  • VGD500 Other

    VGD500

    China
    Category: Other
    Manufacturer: Inficon
    Display: 4 digits Connection-Gauge Side: D-Sub, 15-pin, female Connection-Measurement Cable Side: D-Sub, 15-pin, male Signal: digital input RS232 Pressure Unit (adjustable): Torr (default), mTorr, mbar, Pa
  • VGC083A, VGC083B, VGC083C Vacuum Gauge Controller Other

    VGC083A, VGC083B, VGC083C Vacuum Gauge Controller

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Channels: 3 Display: LED (VGC083A), OLED (VGC083B, VGC083C) Pressure Indication: 1.3×10⁻⁴ to 1333mbar, 1×10⁻⁴ to 1000Torr Connectable gauges with display range: PGE050, BAG050, BAG051, BAG052, BAG053, BAG055, MAG050, MAG060 Sensor Overpressure Protection: 1×10⁻³Torr at 100μA emission current, 5×10⁻⁴Torr at 4μA emission current
  • VGC031 Vacuum Gauge Controller Other

    VGC031 Vacuum Gauge Controller

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Channels: 1 Display: OLED, 4 digits Display Rate: 2s⁻¹ Connectable gauge with display range: 1.3×10⁻⁴ to 1333mbar, 1×10⁻⁴ to 1000Torr, 1.3×10⁻² to 133000Pa Measurement unit (selectable): mbar
  • UL6000 Fab PLUS Other

    UL6000 Fab PLUS

    China
    Category: Other
    Manufacturer: Inficon
    Minimum Detectable Helium Leak Rate (Vacuum Mode): <5×10⁻¹²mbar·L/s Minimum Detectable Helium Leak Rate (Sniffer Mode): <5×10⁻⁶mbar·L/s Maximum Inlet Pressure (MASSIVE Mode): atm.(~1013mbar) Forepump Type: Roots Maximum Air Pumping Speed (Forepump): 36m³/h
  • UL3000 Fab ULTRA Other

    UL3000 Fab ULTRA

    China
    Category: Other
    Manufacturer: Inficon
    Min. detectable leak rate for helium (vacuum method): <5×10^-12mbar l/s Min. detectable leak rate for helium (sniffer mode): <5×10^-9mbar l/s Max. inlet pressure (MASSIVE mode): 1000mbar Pumping speed during evacuation: >36m³/h Helium pumping speed (high sensitive mode ULTRA): 4l/s
  • UL1000 Helium Leak Detector Other

    UL1000 Helium Leak Detector

    China
    Category: Other
    Manufacturer: Inficon
    Smallest Detectable Leak Rate (per AVS 2.1 and EN 1518): <5×10^-12mbar l/s Smallest Detectable Leak Rate (Sniffer Mode): <5×10^-8mbar l/s Inlet Pressure: 15mbar (GROSS), 2mbar (FINE), 0.4mbar (ULTRA) Pumping Speed During Evacuation: 16m³/h at 50Hz, 19m³/h (13.3cfm) at 60Hz He Pumping Speed at the Inlet (EN 1518): 8l/s max (GROSS), 7l/s (FINE), 2.5l/s (ULTRA)
  • Trigon™ BPG552 DualGauge Other

    Trigon™ BPG552 DualGauge

    China
    Category: Other
    Manufacturer: Inficon
    Pressure Range (Pirani sensor): 2x10^-3...1000mbar Pressure Range (crossover range): 5x10^-3...2x10^-2mbar Pressure Range (hot cathode ionisation BA): 5x10^-10...5x10^-3mbar Measurement Range (air, O2, CO, N2): 5x10^-10...1000mbar Accuracy (1x10^-3...100mbar): ±15% of reading
  • Trigon™ BAG552 SingleGauge Other

    Trigon™ BAG552 SingleGauge

    China
    Category: Other
    Manufacturer: Inficon
    Measurement Range: 5×10⁻¹⁰ to 2×10⁻² mbar Accuracy: ±15% of reading Repeatability: 5% of reading, 10⁻⁸ to 2×10⁻² mbar (after 10 min. stabilization) Switching Threshold-On: 2.4×10⁻² mbar Switching Threshold-Off: 3.2×10⁻² mbar
  • Trigon™ BCG552 TripleGauge® Other

    Trigon™ BCG552 TripleGauge®

    China
    Category: Other
    Manufacturer: Inficon
    Pressure Range: 5×10⁻¹⁰...1500mbar Measurement Range: 5×10⁻¹⁰...1500mbar, continuous Accuracy: ±15% of reading (1×10⁻⁸...50mbar), ±5% of reading (50...950mbar), ±2.5% of reading (950...1050mbar) Repeatability: 5% of reading (1×10⁻⁸...1050mbar after 10min stabilization) Switching Threshold: 2.4×10⁻²mbar (on), 3.2×10⁻²mbar (off)
  • TPG361, TPG362, TPG366 Other

    TPG361, TPG362, TPG366

    China
    Category: Other
    Manufacturer: Inficon
    Input Voltage: 100-240VAC±10% Maximum Ambient Temperature: Defined in respective operating manual Protection Class: EN 60204-1 Fuse Rating: 10A Installation Method: Rack-mounted or desktop
  • TGF11 Tracer Gas Filler Other

    TGF11 Tracer Gas Filler

    China
    Category: Other
    Manufacturer: Inficon
    Pressure: 0.05-2barg (0.7-29PSIG) / 0.3-10barg (4.4-145PSIG) Tracer Gas pressure supply: 100-400kPa (1-4barg, 14.5-58PSIG) / 100-1100kPa (1-11barg, 14.5-159.5PSIG) Connections: Push in fittings, OD 6,10,12mm Compressed Air: 300-1000kPa (3-10barg, 43.5-145PSIG) Test gas pressure supply: 100-1100kPa (1-11barg, 14.5-159.5PSIG)
  • Stripe™ CDG100Dhs - 100°C Other

    Stripe™ CDG100Dhs - 100°C

    China
    Category: Other
    Manufacturer: Inficon
    Accuracy (% of reading): 0.2, 0.2, 0.4 Temperature effect zero point (percent FS/°C): 0.0025, 0.0025, 0.005 Temperature effect full scale (% of reading/°C): 0.02, 0.02, 0.02 Pressure max (kPa absolute): 400, 260, 130 Resolution (percent FS): 0.003, 0.003, 0.003
AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →