Selected
- China
- Yokogawa
Current Category:
- 3D Scanner
- Beam Profilers
- Conventional Microscopes
- Displacement Gages
- Sensors
- Fiber Inspection Tools
- Fiber Test & Measurement
- Gas Analysis
- Interferometers
- Laser Scanning and Ranging
- LiDAR
- Material Analysis and Forensics
- Measurement Devices
- Metrology Accessories
- Microscope Accessories
- Microscopes
- Optical Cells
- Optical Inspection
- Optical Metrology
- Optical Power Meters
- Optical Spectrum Analyzers
- Optical Surface Profiler
- Optical Wavelength Meters
- Scanners and Rangefinders
- Size Measurement
- Spectrometers
- Terahertz
- Thermal Solutions
- Waveform Generators and Analyzers
- Other
- Probe Station
- Probe Station Accessories
Country:
More
Photonics Source provides 251 products. Download datasheets, request quotes, and compare function, price, and availability.
-
Rack-Mounted Optoelectronic Test and Measurement System
System Architecture: Floor-standing standardized instrument rack with integrated multi-layer modules Control Computer: Top-mounted desktop workstation with monitor and keyboard Upper Measurement Module: Analysis/measurement instrument with integrated display and front-panel controls Middle Instrument Module: Two benchtop instruments (digital display/readout unit and source/control unit) Lower Power Module: High-power unit with front-panel ventilation grille (forced-air cooling) -
Optical Rail System with Adjustable Optical Mounts
Number of Adjustable Optical Mounts: 4 Number of Central Optical Units: 1 Rail Layout: Linear, dual-section (left/right of central unit) Number of Support Feet: 4 Mounting Method: Rail-mounted, sliding carriers -
WDF File Access Library
Product Type: API software library (Dynamic Link Library, DLL) Supported File Format: WDF (waveform data file saved on Yokogawa measurement instruments) Supported Operating System: Windows 10 (32 bit or 64 bit) / Windows 11, English or Japanese version Application Development Environment: Visual Studio 2017 or later Runtime Requirement: Visual Studio 2017 Redistributable Package -
Laser Photoplotter Photosensitive Film Roll
Product Form: Roll Packaging Method: Black light-tight sealed bag Core Type: Cardboard core Film Surface Color: White/Ivory Base Material: PET polyester base (typical for this film type) -
Electro-Optic Q-Switch Pockels Cell Module
Crystal Material: KD*P/BBO Operating Wavelength Range: 300-1100nm Clear Aperture: 8mm×8mm Half-Wave Voltage @1064nm: ≤4.0kV Extinction Ratio: ≥1000:1 -
Fiber Optic Patch Cord (Coiled Fiber Optic Cable Assembly)
Data Note: No textual specifications were included in the provided material; detailed parameters cannot be extracted -
Precision Waveform Measurement Probes
Maximum Input Voltage: 600V DC+ACpeak Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Resistance/Capacitance: 10MΩ/13.5pF Total Length: 1.5m -
Precision waveform measurement essentials
Maximum Input Voltage: 600V DC+ACpeak Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Resistance/Capacitance: 10MΩ/13.5pF Total Length: 1.5m -
Precision waveform measurement probes and accessories
Maximum Input Voltage: 600VDC+ACpeak Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Capacitance: 13.5pF Total Length: 1.5m -
Precision Waveform Measurement Probes
Maximum Input Voltage: 600V DC+ACpeak Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Resistance/Capacitance: 10MΩ/13.5pF Total Length: 1.5m -
CT Series Current Sensors and Probes
Rated Current DC CT60: 0-60A Rated Current DC CT200: 0-200A Rated Current DC CT1000: 0-1000A Rated Current DC CT1000A: 0-1000A Rated Current DC CT2000A: 0-2000A -
Precision Waveform Measurement Probes and Accessories
Maximum Input Voltage: 600V DC+ACpeak Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Resistance/Capacitance: 10MΩ/13.5pF Total Length: 1.5m -
IS8000 Integrated Software Platform
Supported Devices: DL950, SL2000, WT5000 Maximum Sampling Rate: 20MS/s Supported File Formats: WDF, CSV, CSZ, MAT, MP4, MPEG2-PS Display Resolution: 768x108 dots or higher Operating System: Windows 11 Pro or Enterprise, Windows 10 64-bit Pro or Enterprise -
IS8000 Integrated Software Platform
Supported Devices: DL950, SL2000, WT5000 Operating System: Windows 11 Pro or Enterprise edition, Windows 10 64-bit Pro or Enterprise edition Display Resolution: 1366×768 or higher Data Acquisition Rate: 20MS/s Max Displayed Waveforms: 128 channels×16 groups -
IS8000 Integrated Software Platform
Supported Devices: DL950, SL2000, WT5000 Operating System: Windows 11 Pro or Enterprise, Windows 10 64-bit Pro or Enterprise Display Resolution: 1366×768 or higher Data Acquisition Rate: 20MS/s Max Displayed Waveforms: 128 channels×16 groups -
IS8000 Integrated Software Platform
Supported Devices: DL950, SL2000, WT5000 Operating System: Windows 11 Pro or Enterprise edition, Windows 10 64-bit Pro or Enterprise edition Display Resolution: 1366×768 or higher Data Acquisition Rate: 20MS/s Max. Displayed Waveforms: 128 channels×16 groups -
ScopeCorder Plug-in Modules
Sample Rate: 200MS/s Resolution: 14bit Bandwidth: 40MHz Number of Channels: 2 Isolation: Isolated -
IS8000 Integrated Software Platform
Supported Devices: DL950, SL2000, WT5000 Operating System: Windows 11 Pro or Enterprise edition, Windows 10 64-bit Pro or Enterprise edition Display Resolution: 1366×768 or higher Data Acquisition Rate: 20MS/s Data Format: WDF, CSV, CSZ, MF4, WWF