Selected
- China
Current Category:
Subcategory:
- 3D Scanner(4)
- Beam Profilers(6)
- Conventional Microscopes(17)
- Displacement Gages(30)
- Sensors(230)
- Fiber Inspection Tools(31)
- Fiber Test & Measurement(120)
- Gas Analysis(48)
- Interferometers(12)
- Laser Scanning and Ranging(4)
- LiDAR(41)
- Material Analysis and Forensics(13)
- Measurement Devices(17)
- Metrology Accessories(43)
- Microscope Accessories(19)
- Microscopes(36)
- Optical Cells(1)
- Optical Inspection(23)
- Optical Metrology(48)
- Optical Power Meters(42)
- Optical Spectrum Analyzers(18)
- Optical Surface Profiler(15)
- Optical Wavelength Meters(7)
- Scanners and Rangefinders(5)
- Size Measurement(18)
- Spectrometers(27)
- Terahertz(11)
- Thermal Solutions(24)
- Waveform Generators and Analyzers(5)
- Other(639)
- Probe Station(49)
- Probe Station Accessories(125)
Country:
More
Brand:
- CasTech
- ColorSpace
- Elite16
- EngWx
- Eoulu
- Fibretop
- Foctek
- GdTumtec
- HbSais
- Hesaitech
- Hoyatek
- Hroptron
- Inficon
- JcNanoControl
- Jjk
- Kaitengtx
- Keyence
- Koc
- KonicaMinolta
- Kyky
- LitraTech
- Micro-Epsilon
- Mvotem
- Opwill
- PhenixOptics
- Santec
- Slamtec
- Sowaysensor
- Steligent
- SymcTec
- Tekcn
- Toptica-China
- Ulirvision
- UlvacShanghai
- Uni-Trend
- Uwlaser
- WaveLabSci
- Wayeal
- Wayho
- WekonTech
- Whhxykj
- WhPrecise
- Xmgttx
- Ybsemi-Solution
- Yokogawa
- Ytdq
- ZcHightech
- ZhVacuum
- ZkTel
Photonics Source provides 1588 products. Download datasheets, request quotes, and compare function, price, and availability.
-
AQ7800 Ambient Air Non-Methane Total Hydrocarbons Continuous Monitoring System (Direct Measurement Method)
Detection Method: GC-FID Measurement Method: 直测法(Direct Measurement) Measured Components: 甲烷、非甲烷总烃(CH4、NMHC) Detection Limit: ≤1ppbC Latest Standard Detection Limit Requirement: 20ppbC -
AQ7100 Micro Ambient Air Quality Monitoring System
Monitoring Factors: SO2、NO2、CO、O3、PM2.5、PM10 Meteorological Parameters: 风速、风向、温度、湿度、大气压 Monitoring Network Mode: 高密度网格化布局、群防式协同监测网络 Data Application: 污染来源追踪、预警预报、大数据分析 Model Number: AQ7100 -
Rack-Mounted Optoelectronic Test and Measurement System
System Architecture: Floor-standing standardized instrument rack with integrated multi-layer modules Control Computer: Top-mounted desktop workstation with monitor and keyboard Upper Measurement Module: Analysis/measurement instrument with integrated display and front-panel controls Middle Instrument Module: Two benchtop instruments (digital display/readout unit and source/control unit) Lower Power Module: High-power unit with front-panel ventilation grille (forced-air cooling) -
Optical Rail System with Adjustable Optical Mounts
Number of Adjustable Optical Mounts: 4 Number of Central Optical Units: 1 Rail Layout: Linear, dual-section (left/right of central unit) Number of Support Feet: 4 Mounting Method: Rail-mounted, sliding carriers -
WDF File Access Library
Product Type: API software library (Dynamic Link Library, DLL) Supported File Format: WDF (waveform data file saved on Yokogawa measurement instruments) Supported Operating System: Windows 10 (32 bit or 64 bit) / Windows 11, English or Japanese version Application Development Environment: Visual Studio 2017 or later Runtime Requirement: Visual Studio 2017 Redistributable Package -
Laser Photoplotter Photosensitive Film Roll
Product Form: Roll Packaging Method: Black light-tight sealed bag Core Type: Cardboard core Film Surface Color: White/Ivory Base Material: PET polyester base (typical for this film type) -
Electro-Optic Q-Switch Pockels Cell Module
Crystal Material: KD*P/BBO Operating Wavelength Range: 300-1100nm Clear Aperture: 8mm×8mm Half-Wave Voltage @1064nm: ≤4.0kV Extinction Ratio: ≥1000:1 -
Fiber Optic Patch Cord (Coiled Fiber Optic Cable Assembly)
Data Note: No textual specifications were included in the provided material; detailed parameters cannot be extracted -
Dual-Channel Rack-Mount Fiber Optic Switch Module
Number of Optical Ports: 2 Fiber Connector Type: APC Control Interface: D-Sub Form Factor: Rack-mount metal chassis Laser Safety Label: Class laser warning label equipped -
Funnel-Top Micro Quartz Cuvette
Material: UV-grade quartz glass (JGS1) Spectral Range: 190–2500nm Optical Path Length: 10mm External Dimensions: 12.5×12.5×45mm Z Dimension (Beam Center Height): 15mm -
Benchtop Thin-Film Thickness Analyzer (Spectroscopic Reflectometer)
Measurement Principle: Spectral reflectance Thickness Measurement Range: 15Å–70µm Wavelength Range: 380–1050nm Thickness Accuracy: ±0.4% Repeatability (1σ): ≤0.1% -
Filmetrics F3-CS Compact Thin-Film Thickness Measurement System
Measurement Principle: Spectral Reflectance Film Thickness Range: 15nm-75μm Wavelength Range: 380-1050nm Light Source: Tungsten-Halogen Lamp Spectrometer Detector: CCD Array -
SpecMetis Spectral Remote Sensing Industry Application Software
Supported Vegetation Indices: NDVI Supported Vegetation Indices: EVI Supported Vegetation Indices: NDRE Supported Vegetation Indices: PSRI Supported Vegetation Indices: RVI