AQ6151B Optical Wavelength Meter
The AQ6151B Optical Wavelength Meter is a high-precision instrument designed for fast and accurate wavelength measurements. It is ideal for applications in R&D and manufacturing, particularly in the fields of WDM transmission systems, optical transceivers, and laser source testing.
Specification Snapshot
Wavelength Range Standard (-12)
1270 to 1650nm
Wavelength Range Extended (-22)
1200 to 1700nm
Wavelength Range Wide Range (-32)
900 to 1700nm
Return Loss
≥35dB
Request a Quote
Download Datasheet
Chat
Overview
The AQ6151B Optical Wavelength Meter is a high-precision instrument designed for fast and accurate wavelength measurements. It is ideal for applications in R&D and manufacturing, particularly in the fields of WDM transmission systems, optical transceivers, and laser source testing.
Specifications
| Parameter | Value |
|---|---|
| Wavelength Range Standard (-12) | 1270 to 1650nm |
| Wavelength Range Extended (-22) | 1200 to 1700nm |
| Wavelength Range Wide Range (-32) | 900 to 1700nm |
| Wavelength Accuracy Standard (-12) | ±0.2ppm (±0.3pm at 1550nm, update rate: Normal), ±0.5ppm (±0.8pm at 1550nm, update rate: Fast) |
| Wavelength Accuracy Extended (-22) | ±0.2ppm (±0.3pm at 1550nm, update rate: Normal), ±0.5ppm (±0.8pm at 1550nm, update rate: Fast) |
| Wavelength Accuracy Wide Range (-32) | ±0.2ppm (±0.3pm at 1550nm, update rate: Normal), ±0.5ppm (1200 to 1700nm, ±0.8pm at 1550nm, update rate: Fast), ±1.5ppm (900 to 1200nm, ±1.4pm at 900nm) |
| Minimum Resolvable Separation | 5GHz (40pm at 1550nm, update rate: Normal), 10GHz (80pm at 1550nm, update rate: Fast) |
| Display Resolution | 0.01dB |
| Power | -10dBm (1550nm, -30dBm or higher) |
| Linearity | ±0.3dB (1550nm, -30dBm or higher) |
| Polarization Dependency | ±0.05dB (1550nm, -30dBm or higher) |
| Maximum Number of Wavelengths | 1024 (Multi-wavelength), 1 (Single-wavelength) |
| Minimum Input Power Standard (-12) | -40dBm (1270 to 1600nm), -30dBm (1600 to 1650nm) |
| Minimum Input Power Extended (-22) | -40dBm (1200 to 1600nm), -30dBm (1600 to 1700nm) |
| Minimum Input Power Wide Range (-32) | -40dBm (900 to 1200nm, 1600 to 1700nm), -30dBm (1200 to 1600nm) |
| Maximum Input Power | +10dBm (total input power) |
| Safe Maximum Input Power | +18dBm (total input power) |
| Applicable optical fiber | SM (ITU-T G.652) |
| Return Loss | ≥35dB |
| Measurement Time | 0.2s or less (update rate: Fast), 0.3s or less (update rate: Normal) |
| Display | 5.7-inch color LCD (640×480 dots) |
| Data Storage | Internal: 256MB or more, External: USB |
| Interfaces | GP-IB, ETHERNET, USB, VGA output |
| Remote Control | GP-IB, ETHERNET |
| Optical Connector | FC/PC or SC/PC (AQ9441 Universal Adapter) |
| Warm-Up Time | 60 minutes or more |
| Power Requirements | 100 to 120VAC, 50/60Hz, approx. 100VA |
| Environmental Conditions | Performance guarantee temperature: +10 to +30°C, operating temperature: +5 to +35°C, storage temperature: -10 to +50°C, humidity: 20 to 85%RH (no condensation) |
| Dimensions and Mass | Approx. 426(W)×132(H)×459(D)mm (excluding protrusions), approx. 11kg |
| Safety Standards | EN 61010-1, EN 60825-1:2014+A11:2021, IEC 60825-1:2014, GB/T 22471.1-2024, Class 1 |
| EMC Emission | EN 61326-1 Class A, EN 55011 Class A Group 1, EN 61000-3-2, EN 61000-3-3, RCM EN 55011 Class A Group 1, Korea Electromagnetic Conformity Standard |
| EMC immunity | EN 61326-1 Table 2 |
| Recommended Calibration Period | 1 year |
Applications
1. WDM transmission systems testing 2. Calibration of test systems 3. Lasers and optical transceivers testing 4. Measurement of modulated signals 5. Adjustment and inspection of tunable lasers 6. Measurement of all channels of 40 G and 100 G optical transceivers with WDM technology
Key Features
1. High wavelength accuracy of ±0.2ppm 2. Simultaneous measurement of up to 1024 wavelengths 3. Fast measurement in 0.2 seconds 4. CW, modulated transceiver, and optical filter measurement 5. High performance with low-power input signals 6. User-friendly interfaces with USB and LAN connectivity 7. Built-in analysis functions including drift analysis and Fabry-Perot laser analysis 8. Long-term stability and reduced lifetime ownership costs
Datasheet
Product Datasheet
PDF
Supplier Information
<p>Yokogawa was founded in 1915 and has more than 6,000 test and measurement instrument patents. It focuses on developing and providing the best test and measurement solutions. Yokogawa Measurement Technology (Shanghai) Co., Ltd. ensures the excellent quality of the brand and contributes to the growth of China's industry.</p>
Contact Us
Loading...
GetExperimental Plan
Name
Phone
+86
Organization
Use Case

Global Photonics Products
Database Platform
Database Platform
With 16 years of experience, we provide high-quality products and services to universities, research institutes, and industry.
50+ Detailed Categories · 3,000+ Global Brands · 100,000+ Photonics Products
1 Million+
In-depth analysis of professional academic resources in photonics
300,000
ProductsDatasheets Available Free
We will keep your personal information strictly confidential.
Product Quote
+86
* Select the quoting party:
By submitting, you agree to the User Service Agreement and Privacy Policy