Polarization-maintaining WDM with isolation
The polarization-maintaining isolator-WDM hybrid offers low insertion loss, high extinction ratio, high isolation, high return loss, stability and reliability. It suits fiber amplifiers requiring combined signal and pump wavelengths with stable signal isolation.
Request a Quote
Download Datasheet
Overview
The polarization-maintaining isolator-WDM hybrid offers low insertion loss, high extinction ratio, high isolation, high return loss, stability and reliability. It suits fiber amplifiers requiring combined signal and pump wavelengths with stable signal isolation.
Specifications
| Parameter | Value |
|---|---|
| Signal port - Center wavelength [Signal port - Grade : Single stage / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 1550 nm |
| Signal port - Center wavelength [Signal port - Grade : Single stage / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 1064 nm |
| Signal port - Center wavelength [Signal port - Grade : Dual stage / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 1550 nm |
| Signal port - Center wavelength [Signal port - Grade : Dual stage / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 1064 nm |
| Signal port - Operating wavelength [Signal port - Grade : Single stage / Signal port - Center wavelength : 1550 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 1528~1565 nm |
| Signal port - Operating wavelength [Signal port - Grade : Single stage / Signal port - Center wavelength : 1064 nm / Pump port - Operating wavelength range : 980 nm] | 1020~1080 nm |
| Signal port - Operating wavelength [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1550 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 1528~1565 nm |
| Signal port - Operating wavelength [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1064 nm / Pump port - Operating wavelength range : 980 nm] | 1020~1080 nm |
| Signal port - maximum insertion loss [Signal port - Grade : Single stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 0.8 dB |
| Signal port - maximum insertion loss [Signal port - Grade : Single stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 2.2 dB |
| Signal port - maximum insertion loss [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 1.0 dB |
| Signal port - maximum insertion loss [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 3.6 dB |
| Signal port - typical peak isolation [Signal port - Grade : Single stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 40 nm |
| Signal port - typical peak isolation [Signal port - Grade : Single stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 40 nm |
| Signal port - typical peak isolation [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 55 nm |
| Signal port - typical peak isolation [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 55 nm |
| Signal port - minimum signal isolation [Signal port - Grade : Single stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 30 nm |
| Signal port - minimum signal isolation [Signal port - Grade : Single stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 30 nm |
| Signal port - minimum signal isolation [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 45 nm |
| Signal port - minimum signal isolation [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 45 nm |
| Min Extinction ratio [Signal port - Grade : Single stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm / @23℃] | 20 dB |
| Min Extinction ratio [Signal port - Grade : Single stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm / @23℃] | 20 dB |
| Min Extinction ratio [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm / @23℃] | 20 dB |
| Min Extinction ratio [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm / @23℃] | 20 dB |
| Pump port - Operating wavelength range [Signal port - Grade : Single stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm] | 980, 1480 |
| Pump port - Operating wavelength range [Signal port - Grade : Single stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm] | 980 nm |
| Pump port - Operating wavelength range [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm] | 980, 1480 |
| Pump port - Operating wavelength range [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm] | 980 nm |
| Pump port - maximum insertion loss [Signal port - Grade : Single stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 0.6 dB |
| Pump port - maximum insertion loss [Signal port - Grade : Single stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 0.6 dB |
| Pump port - maximum insertion loss [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 0.6 dB |
| Pump port - maximum insertion loss [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 0.6 dB |
| Pump port - typical insertion loss [Signal port - Grade : Single stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 0.4 dB |
| Pump port - typical insertion loss [Signal port - Grade : Single stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 0.4 dB |
| Pump port - typical insertion loss [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 0.4 dB |
| Pump port - typical insertion loss [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 0.4 dB |
| Min Return loss [Signal port - Grade : Single stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 50 dB |
| Min Return loss [Signal port - Grade : Single stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 50 dB |
| Min Return loss [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 50 dB |
| Min Return loss [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 50 dB |
| Max Optical power [Signal port - Grade : Single stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 300 mW |
| Max Optical power [Signal port - Grade : Single stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 300 mW |
| Max Optical power [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 300 mW |
| Max Optical power [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 300 mW |
| Maximum tensile load [Signal port - Grade : Single stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 5 N |
| Maximum tensile load [Signal port - Grade : Single stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 5 N |
| Maximum tensile load [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1550 nm / Signal port - Operating wavelength : 1528~1565 nm / Pump port - Operating wavelength range : 980, 1480 nm] | 5 N |
| Maximum tensile load [Signal port - Grade : Dual stage / Signal port - Center wavelength : 1064 nm / Signal port - Operating wavelength : 1020~1080 nm / Pump port - Operating wavelength range : 980 nm] | 5 N |
Applications
Pump lasers; Optical cutting; Research
Key Features
Low insertion loss; High return loss; High extinction ratio; High isolation; High stability and reliability
Datasheet
Please provide your email to download the datasheet.
Your name
Email Address
Invalid email format. Please try again.
Send Request
Supplier Information
Shenzhen Bokosi Optoelectronic Technology Co., Ltd. focuses on the R&D, sales, and technical development of optoelectronic products. It also deals in optical transmission products, power batteries, laser equipment and accessories, electronic products and components, and provides import and export services.
Contact Us
Loading...
GetExperimental Plan
Name
Phone
+86
Organization
Use Case

Global Photonics Products
Database Platform
Database Platform
With 16 years of experience, we provide high-quality products and services to universities, research institutes, and industry.
50+ Detailed Categories · 3,000+ Global Brands · 100,000+ Photonics Products
1 Million+
In-depth analysis of professional academic resources in photonics
300,000
ProductsDatasheets Available Free
We will keep your personal information strictly confidential.
Product Quote
+86
* Select the quoting party:
By submitting, you agree to the User Service Agreement and Privacy Policy