AS6000 Motor Energy Efficiency Analysis Software
Supported Operating Systems: Windows 7 (Version SP1) 32bit/64bit, Windows 8.1 32bit/64bit, Windows 10 (Version 1607 and later) 32bit/64bit, Windows 11 32bit/64bit CPU: At least Intel Core i7 2.60GHz RAM: At least 8GB Hard Disk: At least 2GB space Mouse: OS supported mouse -
YPFS Series Voltage Interruption, Dips, and Variations Test System
Input Voltage: 4×480Vac Single-phase Current: 16A/32A/64A/100A/200A Voltage Dips: 40%,50%,60%,70%,80%(单相) 30%,40%,50%,60%,70%,80%(三相,带Phase Shift) Inrush Current Capability: 1000A(三相) Voltage Variations: ±40% -
Harmonic/Flicker Measurement Software 761922
Harmonic Measurement Range: 45Hz to 66Hz Harmonic Measurement Method: PLL synchronization method Harmonic Window Length: 12 cycles or 16 cycles Harmonic Analysis Filter: 5Hz Harmonic Measurement Frequency Range: Up to 50th order -
Model 709811 Additional Option License for the DLM3000
Supported Models: DLM3024, DLM3034, DLM3054 Firmware Version: Version supporting the option to be added -
700987 Isolation Logic Probe
Number of inputs: 8 Input format: Isolated (all bits are isolated) Input Connector: Safety terminal type (for banana plug) × 8 Input switching: AC/DC input can be switched for each bit Input signal display: Hi/Lo level is detected for each bit, and LED lights when Hi -
DLM5034, DLM5038, DLM5054, DLM5058 Mixed Signal Oscilloscope
Voltage Sensitivity: 200mV/div to 500mV/div Time Axis Settings: 200μs/div to 100μs/div Trigger Position: 30% to 50% Trigger Slope: Rising/Falling/Both Data Format: PNG -
Model 2792A Standard Resistor
Model: 2792A-01, 2792A-02, 2792A-03, 2792A-04, 2792A-05 Nominal Value: 0.01Ω, 0.1Ω, 1Ω, 10Ω, 100Ω Accuracy: ±0.01%, ±0.05%, ±0.1% Temperature Coefficient: ±25ppm/°C, ±50ppm/°C Drift per Year: ±0.01%, ±0.05% -
Model 700939 FET Probe for DL Series
Frequency Bandwidth: DC-900MHz Attenuation Ratio: 10:1 ±2% Output Offset Voltage: ±2mV Input Voltage Range: 10Vp-p Non-destructive Input Voltage Range: ±40V (DC+AC peak) -
Model 702906 10:1 Passive Probe
Attenuation Ratio: 10:1 Connector Type: BNC with probe ID pin Frequency Band: DC to 250MHz (-3dB) Input Resistance: 10MΩ±2% Input Capacitance: 15pF±2pF -
Model 701940 10 MHz Passive Probe
Probe Length: 1.5m Connector Type: BNC Input Resistance: 10MΩ±2% Matching Input Capacity: Approx. 17pF to 45pF Input Capacitance: 22pF±10% -
PB500 500 MHz Passive Probe (10:1)
Probe Length: Approx.1.5m Connector Type: BNC Input Resistance: 10MΩ with an oscilloscope with an input impedance of 1MΩ Input Capacitance: 12.5pF (typical) Attenuation Ratio: 10:1 -
500 MHz Passive Probe (10:1)
Probe Length: Approx.1.3m Connector Type: BNC Input Resistance: 10MΩ (in conjunction with an oscilloscope with an input impedance of 1MΩ) Input Capacitance: 10.5pF (typical) Attenuation Ratio: 10:1 -
200 MHz Passive Probe (10:1)
Probe Length: Approx.1.5m Connector Type: BNC Input Resistance: 10MΩ±2% Input Capacitance: 13pF(typical) Attenuation Ratio: 10:1 -
Model 700929 10:1 Probe
Cable Length: 1.5m Weight: 70g (probe only) Frequency Bandwidth: DC to 100MHz (-3dB) Attenuation Ratio: 10:1 ±2% Maximum Input Voltage: Between tip and shield: Measurement category I 1000V, Measurement category II 1000V; Between shield and ground: Measurement category I 1000V, Measurement category II 1000V -
MY600 Digital Insulation Tester
Rated measuring voltage 50V: 100MΩ Rated measuring voltage 100V: 200MΩ Rated measuring voltage 125V: 200MΩ Rated measuring voltage 250V: 250MΩ Rated measuring voltage 500V: 500MΩ -
TC-K Probe
Model: 90020B, 90021B, 90022B, 90023B, 90024B, 90030B, 90031B, 90032B, 90033B Measurement Range: -50~600°C, -50~600°C, -50~500°C, -20~250°C, -20~250°C, -20~500°C, -20~500°C, -20~500°C, -20~500°C Sheath Diameter: 6.4mm, 6.4mm, 6.4mm, 6.4mm, 6.4mm, 6.4mm, 6.4mm, 6.4mm, 6.4mm Sheath Length: 200mm, 150mm, 150mm, 150mm, 150mm, 150mm, 150mm, 150mm, 150mm Tolerance: ±(T×3.5%+1.5°C), ±(T×3.5%+1.5°C), ±(T×3.5%+1.5°C), ±(T×3.5%+1.5°C), ±(T×3.5%+1.5°C), ±(T×3.5%+1.5°C), ±(T×3.5%+1.5°C), ±(T×3.5%+1.5°C), ±(T×3.5%+1.5°C) -
MT300 Digital Manometer
Operating System: Windows 10 or Windows 11 Processor: Core2 Duo 2GHz or faster Memory: 1GB or more Firmware Version: 1.01 (2019/09/05 17:38) Boot Version: 3.16 -
AQ2200 Series Multi-Application Test System Remote Viewer
PC System Requirements: A PC running Windows 7 or Windows 8.1 with a CPU capable of running the OS smoothly and at least 256MB of memory. Operating System: Windows 7(32-bit/64-bit) or Windows 8.1(32-bit/64-bit) Hard Disk Space: At least 10MB of free space for the installation. Display Resolution: 1024×768 dots or better. Display Color: 256 colors or more (65536 colors or more recommended).