Current Category:
- 3D Scanner
- Beam Profilers
- Conventional Microscopes
- Displacement Gages
- Sensors
- Fiber Inspection Tools
- Fiber Test & Measurement
- Gas Analysis
- Interferometers
- Laser Scanning and Ranging
- LiDAR
- Material Analysis and Forensics
- Measurement Devices
- Metrology Accessories
- Microscope Accessories
- Microscopes
- Optical Cells
- Optical Inspection
- Optical Metrology
- Optical Power Meters
- Optical Spectrum Analyzers
- Optical Surface Profiler
- Optical Wavelength Meters
- Scanners and Rangefinders
- Size Measurement
- Spectrometers
- Terahertz
- Thermal Solutions
- Waveform Generators and Analyzers
- Other
- Probe Station
- Probe Station Accessories
Country:
More
Photonics Source provides 639 products. Download datasheets, request quotes, and compare function, price, and availability.
-
MAG470 Inverted Magnetron Gauge
Measurement Range (air, N₂): 5×10⁻¹¹ mbar to 1×10⁻² mbar (3.8×10⁻¹¹ Torr to 7.5×10⁻³ Torr) Accuracy (N₂): ±30% of reading Repeatability (N₂): ±5% of reading Mounting Orientation: any Admissible Pressure (absolute): ≤10bar (limited to inert gases) -
MPG40x High Vacuum Gauge
Measurement Range (Air, N₂): 5×10⁻⁹...1000mbar Measurement Range (Air, N₂) Torr: 3.8×10⁻⁹...760 Accuracy (N₂): 1×10⁻⁸...100mbar ±30% Repeatability: 1×10⁻⁸...100mbar ±5% Installation Position: any -
MAG084
Measurement System: cold cathode ionization (inverted magnetron principle) Display Range (Air N2): 5×10^-9mbar to 1×10^-2mbar Measurement Range (Air N2): 1×10^-8mbar to 5×10^-3mbar Accuracy (Air N2): 30% of reading Repeatability (typical): 5% of reading -
MAG050, MAG060, MAG070
Measurement System: Cold cathode ionization (inverted magnetron principle) Measurement Range MAG050: 2×10⁻²...5×10⁻³ mbar Measurement Range MAG060: 1×10⁻¹⁰...5×10⁻³ mbar Measurement Range MAG070: 1×10⁻¹¹...5×10⁻³ mbar Accuracy: 30% of reading -
LDS Arnova
Minimum detectable leak rate (Air): 1×10^-4mbar/s Minimum detectable leak rate (Argon): 1×10^-6mbar/s Units of measurement (options): mbar/s,Pa,m3/s,atmcc/s,g/a,ppm Maximum permissible input pressure: 18mbar (Gross mode), 0.9mbar (Fine mode), 0.2mbar (Ultra mode) Response Time: <1s -
LDM150 and LDM150R Refrigerant Monitors
Model: 743-202-HFC, 743-202-HFCHV, 743-202-CO2, 743-202-CO2HV, 743-202-NH3, 743-202-NH3HV, 743-203-HFC, 743-203-HFCHV, 743-203-CO2, 743-203-CO2HV, 743-203-NH3, 743-203-NH3HV, 743-203-R290, 743-203-R290HV Compatible Refrigerants: R22, R32, R134a, R404a, R407c, R410a, R422b, R448a, R449a, R452a, R452b, R507, AZ50, R1234yf, CO2, Ammonia, R290, R600, R441a Power Input: 230VAC or 12-24V (AC/DC), 50-60Hz Cable Length: Not included (user provided), 5m (16.5ft) Certification: CE, IP54, IP67, IP56, ATEX -
IRwin Methane Leak Detector
Ex Classification: Ex II 1G, Ex ia IIC T3 Ga (Zone 0) Intrinsically safe: Class I, Division 1, Groups B, C and D Detectable gases: Methane Detectable gases: carbon dioxide Detectable gases: ethane -
Multipoint Refrigerant Monitors
Compatible Refrigerants: HFCs Compatible Refrigerants: HCFCs Compatible Refrigerants: HFOs Power Input: 12-24V (AC/DC), 50-60Hz Cable Length: Not included (user provided) -
IRG080 Ion Reference Gauge - Passive
Measurement System: hot cathode ionization Electrode System Configuration: according to ISO TS 6737 Measurement Range (N2): <1×10^-8...1×10^-4mbar, <1×10^-8...1×10^-2Pa Sensitivity (N2, typical): 29mbar^-1 Accuracy (N2, typical): ±1% of reading -
IM540 Vacuum Gauge Controller
Measurement channel: 3 Display: LCD Display: LED backlight Display Rate: 4s⁻¹ Measurement Range IE414 (Bayard-Alpert): 1×10⁻¹¹...1×10⁻²mbar | 0.75×10⁻¹¹...0.75×10⁻²Torr -
IRC081 Ion Reference Gauge Controller
Measurement channel: 1 Measurement rate: 1s⁻¹ User Interface: Front panel, PC-software Manual control: 5 knobs Remote Control: via USB 2.0 with PC software 'IRC081 user interface' -
HPG400 High Pressure Pirani Gauge
Measurement Range (Air, N2): 1.5×10⁻⁶…750Torr Accuracy: ±15% of reading Repeatability: 2% of reading Hot Cathode Emission, Optional: 5×10⁻²…1mbar Optional Component 1: 1mbar -
IE414 & IE514 Sensors
Measurement System: Hot cathode ionization Electrode System Configuration IE414: Bayard-Alpert Electrode System Configuration IE514: Extractor system Measurement Range (N2) IE414: 2×10^-11...1×10^-2mbar Measurement Range (N2) IE514: 2×10^-12...1×10^-4mbar -
Gemini™ MxG5xx
Measurement Range (Air, N2) MAG5xx (mbar): 1×10⁻⁹...1×10⁻² Measurement Range (Air, N2) MPG5xx (mbar): 1×10⁻⁹...1000 Measurement Range (Air, N2) MAG5xx (Torr): 7.6×10⁻¹⁰...7.6×10⁻³ Measurement Range (Air, N2) MPG5xx (Torr): 7.6×10⁻¹⁰...760 Standard Accuracy (N2) MAG5xx: 30% of reading -
HLD6000 CO2 Leak Detector
Detectable Refrigerants: R600a/R290/R744 (CO2), Halogen-based refrigerants Minimum Detectable Leak Rate (Single Gas Detection Handle): 1.0g/a (0.03oz/a) Minimum Detectable Leak Rate (Smart Handle): 0.5g/a (0.014oz/a) Response Time: <1s Leak Rate Units: g/a, mbar, Vs, oz/a, lb/a, Pa m³/s -
GAS-Mate Combustible Gas Leak Detector
Includes: GAS-Mate, Combustible gas sensor, Two D-size alkaline batteries, Carrying case Compatible Refrigerants: Propane (R290), Isobutane (R600a), R441a, Hydrogen forming gas (95/5), Natural gas, Methane, Ammonia Sensitivity: 5ppm for methane, propane (R290), isobutane (R600a), and hydrogen; 1ppm for gasoline Power source: Two D-size alkaline batteries (use Duracell MN1300 to maintain intrinsically safe approval) Battery Life: 25 hours -
Edge CDG100D2
Accuracy: % of reading 0.15 Temperature Effect: % of reading/°C 0.02 Pressure, Max: kPa (absolute) 400 Resolution: percent FS 0.003 Recommended Minimum Reading: percent FS 0.01