Current Category:
- 3D Scanner
- Beam Profilers
- Conventional Microscopes
- Displacement Gages
- Sensors
- Fiber Inspection Tools
- Fiber Test & Measurement
- Gas Analysis
- Interferometers
- Laser Scanning and Ranging
- LiDAR
- Material Analysis and Forensics
- Measurement Devices
- Metrology Accessories
- Microscope Accessories
- Microscopes
- Optical Cells
- Optical Inspection
- Optical Metrology
- Optical Power Meters
- Optical Spectrum Analyzers
- Optical Surface Profiler
- Optical Wavelength Meters
- Scanners and Rangefinders
- Size Measurement
- Spectrometers
- Terahertz
- Thermal Solutions
- Waveform Generators and Analyzers
- Other
- Probe Station
- Probe Station Accessories
Country:
More
Photonics Source provides 639 products. Download datasheets, request quotes, and compare function, price, and availability.
-
VGC083A, VGC083B, VGC083C Vacuum Gauge Controller
Measurement Channels: 3 Display: LED (VGC083A), OLED (VGC083B, VGC083C) Pressure Indication: 1.3×10⁻⁴ to 1333mbar, 1×10⁻⁴ to 1000Torr Connectable gauges with display range: PGE050, BAG050, BAG051, BAG052, BAG053, BAG055, MAG050, MAG060 Sensor Overpressure Protection: 1×10⁻³Torr at 100μA emission current, 5×10⁻⁴Torr at 4μA emission current -
VGC031 Vacuum Gauge Controller
Measurement Channels: 1 Display: OLED, 4 digits Display Rate: 2s⁻¹ Connectable gauge with display range: 1.3×10⁻⁴ to 1333mbar, 1×10⁻⁴ to 1000Torr, 1.3×10⁻² to 133000Pa Measurement unit (selectable): mbar -
UL6000 Fab PLUS
Minimum Detectable Helium Leak Rate (Vacuum Mode): <5×10⁻¹²mbar·L/s Minimum Detectable Helium Leak Rate (Sniffer Mode): <5×10⁻⁶mbar·L/s Maximum Inlet Pressure (MASSIVE Mode): atm.(~1013mbar) Forepump Type: Roots Maximum Air Pumping Speed (Forepump): 36m³/h -
UL3000 Fab ULTRA
Min. detectable leak rate for helium (vacuum method): <5×10^-12mbar l/s Min. detectable leak rate for helium (sniffer mode): <5×10^-9mbar l/s Max. inlet pressure (MASSIVE mode): 1000mbar Pumping speed during evacuation: >36m³/h Helium pumping speed (high sensitive mode ULTRA): 4l/s -
UL1000 Helium Leak Detector
Smallest Detectable Leak Rate (per AVS 2.1 and EN 1518): <5×10^-12mbar l/s Smallest Detectable Leak Rate (Sniffer Mode): <5×10^-8mbar l/s Inlet Pressure: 15mbar (GROSS), 2mbar (FINE), 0.4mbar (ULTRA) Pumping Speed During Evacuation: 16m³/h at 50Hz, 19m³/h (13.3cfm) at 60Hz He Pumping Speed at the Inlet (EN 1518): 8l/s max (GROSS), 7l/s (FINE), 2.5l/s (ULTRA) -
Trigon™ BPG552 DualGauge
Pressure Range (Pirani sensor): 2x10^-3...1000mbar Pressure Range (crossover range): 5x10^-3...2x10^-2mbar Pressure Range (hot cathode ionisation BA): 5x10^-10...5x10^-3mbar Measurement Range (air, O2, CO, N2): 5x10^-10...1000mbar Accuracy (1x10^-3...100mbar): ±15% of reading -
Trigon™ BAG552 SingleGauge
Measurement Range: 5×10⁻¹⁰ to 2×10⁻² mbar Accuracy: ±15% of reading Repeatability: 5% of reading, 10⁻⁸ to 2×10⁻² mbar (after 10 min. stabilization) Switching Threshold-On: 2.4×10⁻² mbar Switching Threshold-Off: 3.2×10⁻² mbar -
Trigon™ BCG552 TripleGauge®
Pressure Range: 5×10⁻¹⁰...1500mbar Measurement Range: 5×10⁻¹⁰...1500mbar, continuous Accuracy: ±15% of reading (1×10⁻⁸...50mbar), ±5% of reading (50...950mbar), ±2.5% of reading (950...1050mbar) Repeatability: 5% of reading (1×10⁻⁸...1050mbar after 10min stabilization) Switching Threshold: 2.4×10⁻²mbar (on), 3.2×10⁻²mbar (off) -
TPG361, TPG362, TPG366
Input Voltage: 100-240VAC±10% Maximum Ambient Temperature: Defined in respective operating manual Protection Class: EN 60204-1 Fuse Rating: 10A Installation Method: Rack-mounted or desktop -
TGF11 Tracer Gas Filler
Pressure: 0.05-2barg (0.7-29PSIG) / 0.3-10barg (4.4-145PSIG) Tracer Gas pressure supply: 100-400kPa (1-4barg, 14.5-58PSIG) / 100-1100kPa (1-11barg, 14.5-159.5PSIG) Connections: Push in fittings, OD 6,10,12mm Compressed Air: 300-1000kPa (3-10barg, 43.5-145PSIG) Test gas pressure supply: 100-1100kPa (1-11barg, 14.5-159.5PSIG) -
Stripe™ CDG100Dhs - 100°C
Accuracy (% of reading): 0.2, 0.2, 0.4 Temperature effect zero point (percent FS/°C): 0.0025, 0.0025, 0.005 Temperature effect full scale (% of reading/°C): 0.02, 0.02, 0.02 Pressure max (kPa absolute): 400, 260, 130 Resolution (percent FS): 0.003, 0.003, 0.003 -
Stripe™ CDG045Dhs
Accuracy: 0.15% of reading Temperature effect at zero point 1000...1Torr/mbar: 0.0025%FS/°C Temperature effect at zero point 0.05...0.05Torr/mbar: 0.005%FS/°C Temperature effect at zero point 0.02...0.01Torr/mbar: 0.01%FS/°C Full scale temperature effect: 0.01% of reading/°C -
Spot™ CDS530D
Full scale (FS) 1000 Torr: 0.5% of reading Full scale (FS) 300 Torr: 0.5% of reading Full scale (FS) 100 Torr: 0.5% of reading Full scale (FS) 30 Torr: 0.5% of reading Full scale (FS) 10 Torr: 0.5% of reading -
Spot CDS500D
Accuracy: 0.5% of reading Temperature Effect on Zero: 0.01% FS/°C Temperature Effect on Span: 0.01% of reading/°C Resolution: 0.01% FS/°C Long time stability: 0.5% FS/year -
Sensistor XRS9012 Hydrogen Leak Detector
Sensitivity: <p>0.7 ppm H2 in air</p> Response Time: <1s Warm-up Time: <6s Output: Speakers, earphone, standard 3.5mm (1/8 in.) jack, >8 ohms Battery Type: Rechargeable lead batteries (gel electrolyte) -
Sensistor Sentrac
Detection Sensitivity: 15g/y Test Gas: Hydrogen Display: Dynamic graphical interface Probe Type: Flexible and ergonomic Operating Temperature: 0°C to 50°C -
SKY® CDG200D
Accuracy: % of reading 0.4 Temperature Effect: % of reading/°C 0.02 Zero: percent FS/°C 0.005 Full Scale: % of reading/°C 0.02 Pressure, Maximum: kPa (absolute) 400 -
Sensistor ILS500 F Leak Detection Filler
Power Supply Voltage: Single Phase, 85-264VAC/47-63Hz Current: 1.0A@100VAC/0.45A@230VAC Rated Power: 120W max./33W typical average Pressure: 0.35-0.7MPa (50-100psi) Peak Consumption at 0.6MPa: 240l/min (508SCFH)