Current Category:
Subcategory:
- 3D Scanner(4)
- Beam Profilers(6)
- Conventional Microscopes(17)
- Displacement Gages(30)
- Sensors(230)
- Fiber Inspection Tools(31)
- Fiber Test & Measurement(120)
- Gas Analysis(48)
- Interferometers(12)
- Laser Scanning and Ranging(4)
- LiDAR(41)
- Material Analysis and Forensics(13)
- Measurement Devices(17)
- Metrology Accessories(43)
- Microscope Accessories(19)
- Microscopes(36)
- Optical Cells(1)
- Optical Inspection(23)
- Optical Metrology(48)
- Optical Power Meters(42)
- Optical Spectrum Analyzers(18)
- Optical Surface Profiler(15)
- Optical Wavelength Meters(7)
- Scanners and Rangefinders(5)
- Size Measurement(18)
- Spectrometers(27)
- Terahertz(11)
- Thermal Solutions(24)
- Waveform Generators and Analyzers(5)
- Other(639)
- Probe Station(49)
- Probe Station Accessories(125)
Country:
More
Brand:
- Exfo
- CasTech
- ColorSpace
- Elite16
- EngWx
- Eoulu
- Fibretop
- Foctek
- GdTumtec
- HbSais
- Hesaitech
- Hoyatek
- Hroptron
- Inficon
- JcNanoControl
- Jjk
- Kaitengtx
- Keyence
- Koc
- KonicaMinolta
- Kyky
- LitraTech
- Micro-Epsilon
- Mvotem
- Opwill
- PhenixOptics
- Santec
- Slamtec
- Sowaysensor
- Steligent
- SymcTec
- Tekcn
- Toptica-China
- Ulirvision
- UlvacShanghai
- Uni-Trend
- Uwlaser
- WaveLabSci
- Wayeal
- Wayho
- WekonTech
- Whhxykj
- WhPrecise
- Xmgttx
- Ybsemi-Solution
- Yokogawa
- Ytdq
- ZcHightech
- ZhVacuum
- ZkTel
- Burkert
- Trumpf
- EdwardsVacuum
Photonics Source provides 1728 products. Download datasheets, request quotes, and compare function, price, and availability.
-
Sensistor Sentrac
Detection Sensitivity: 15g/y Test Gas: Hydrogen Display: Dynamic graphical interface Probe Type: Flexible and ergonomic Operating Temperature: 0°C to 50°C -
SKY® CDG200D
Accuracy: % of reading 0.4 Temperature Effect: % of reading/°C 0.02 Zero: percent FS/°C 0.005 Full Scale: % of reading/°C 0.02 Pressure, Maximum: kPa (absolute) 400 -
Sensistor ILS500 F Leak Detection Filler
Power Supply Voltage: Single Phase, 85-264VAC/47-63Hz Current: 1.0A@100VAC/0.45A@230VAC Rated Power: 120W max./33W typical average Pressure: 0.35-0.7MPa (50-100psi) Peak Consumption at 0.6MPa: 240l/min (508SCFH) -
SKY® CDG160D
Accuracy: % of reading 0.4 Temperature Effect: % of reading/°C 0.02 Zero Point: percent FS/°C 0.005 Pressure, Max: kPa (absolute) 400 (1000...500 Torr/mbar), 260 (200...1 Torr/mbar) Resolution: percent FS 0.003 -
SKY® CDG100D
Accuracy: 0.2% of reading (1000-500 Torr/mbar), 0.2% of reading (200-1 Torr/mbar), 0.4% of reading (0.5-0.1 Torr/mbar) Temperature Effect: 0.0025% FS/°C (1000-500 Torr/mbar, 200-1 Torr/mbar), 0.005% FS/°C (0.5-0.1 Torr/mbar) Full Scale: 1000 Torr/mbar, 200 Torr/mbar, 0.5 Torr/mbar Maximum Pressure: 400kPa (1000-500 Torr/mbar), 260kPa (200-1 Torr/mbar), 130kPa (0.5-0.1 Torr/mbar) Resolution: 0.003% FS -
SKY® CDG045D
Accuracy: 0.15% of reading Temperature Effect Zero: 0.0025% FS/°C (1000 Torr, 500 Torr), 0.005% FS/°C (0.5 Torr) Temperature Effect Full Scale: 0.01% of reading/°C Maximum Pressure: 400kPa (absolute) (1000 Torr), 260kPa (500 Torr), 130kPa (0.5 Torr) Resolution: 0.003% FS -
SKY® CDG025D-X3
Accuracy: 0.2% of reading (1000 Torr/1100 mbar, 500-10 Torr/mbar, 1 Torr/mbar), 0.25% of reading (0.25 Torr/mbar), 0.5% of reading (0.1 Torr/mbar) Temperature Effect: 0.005% FS/°C (1000 Torr/1100 mbar, 500-10 Torr/mbar, 1 Torr/mbar), 0.015% FS/°C (0.25 Torr/mbar), 0.02% FS/°C (0.1 Torr/mbar) Zero: 0.005% FS/°C (1000 Torr/1100 mbar, 500-10 Torr/mbar), 0.015% FS/°C (0.25 Torr/mbar), 0.02% FS/°C (0.1 Torr/mbar) Full Scale: 0.01% FS/°C (1000 Torr/1100 mbar, 500-10 Torr/mbar, 1 Torr/mbar), 0.03% FS/°C (0.25 Torr/mbar, 0.1 Torr/mbar) Resolution: 0.003% FS -
SKY® CDG025D-X3
Full Scale (FS): 0.1, 0.25, 1, 10, 500, 1000 Torr / 1100 mbar Power Supply Voltage: +14...+30Vdc Current Consumption: ≤0.5A Number of Setpoints: 2 (SP1, SP2) Accuracy: 0.2% of reading (0.1 Torr / mbar: 0.5%) -
SKY® CDG025D
Accuracy: 0.2% of reading Temperature Effect: 0.005% FS/°C Zero Point: 0.015% FS Temperature Response: 0.01% of reading/°C Resolution: 0.003% FS -
Protec P3000(XL) Helium Leak Detector
Minimum Detectable Leak Rate: 1E-7mbarl/s Measurement Range: 1E-6mbarl/s Temperature Range: 10-45°C Sensor Response Time: 450ms Response Time (Including Sniffer Probe): <0.7s -
PCG55x Standard Vacuum Gauge
Measurement Principle: thermal conductance according to Pirani Accuracy (1×10^-3...100mbar): ±15% of reading Accuracy (5×10^-4...1×10^-3mbar): ±50% of reading Accuracy (1000mbar): ±50% of reading Repeatability (1×10^-3...100mbar): 2% of reading -
PSG550, PSG552, PSG554
Measurement Range PSG550: 5×10⁻⁵...1000mbar Measurement Range PSG552: 5×10⁻⁵...1000mbar (3.8×10⁻⁵...750Torr) Measurement Range PSG554: 5×10⁻⁵...1000mbar Accuracy PSG550: ±50% of reading (5×10⁻⁵...1×10⁻³mbar), ±15% of reading (1×10⁻³...100mbar), ±50% of reading (100...1000mbar) Accuracy PSG552: ±50% of reading (5×10⁻⁵...1×10⁻³mbar), ±15% of reading (1×10⁻³...100mbar), ±50% of reading (100...1000mbar) -
Porter™ CDG020D
Accuracy: 1% (3CA3-xxx-xxx), 0.5% (3CA4-xxx-xxx) Temperature Coefficient: 0.02 percent FS/°C Temperature Drift: 0.02 % of reading/°C Resolution: 0.05 percent FS Long-term Stability: 0.5 percent FS/yr -
PSG010, PSG017, PSG018
Measurement System: Pirani Measurement Range: 8×10⁻⁴ to 1000 mbar Accuracy PSG010: ±20% of reading in the range of 1×10⁻³ to 10 mbar, ±2× reading in the range of ≤10² mbar Accuracy PSG017: ±10% of reading in the range of 1×10⁻² to 100 mbar, ±2× reading in the range of ≤10² mbar Accuracy PSG018: ±10% of reading in the range of 1×10⁻² to 100 mbar, ±5× reading in the range of ≤10² mbar -
PPG570 ATM to Medium Vacuum Gauge + ATM Switch
Measuring Principle: MEMS Piezo resistive diaphragm Pressure Range: 2...1333mbar Measuring Range: 1×10^-6...1333mbar Accuracy (1100...1333mbar): 0.5% of reading Accuracy (800...1099mbar): 0.25% of reading -
PPG550 ATM to Medium Vacuum Gauge
Measurement Principle: MEMS Piezo resistive diaphragm Pressure Range: 2...1333mbar Measuring Range (N2): 1×10⁻⁶...1333mbar Accuracy (1100-1333mbar): 0.5% of reading Accuracy (800-1099mbar): 0.25% of reading -
PGE500
Measurement Range: 1.3×10⁻⁴–1333mbar, 1×10⁻⁴–1000Torr, 1.3×10⁻²–133000Pa Accuracy: ±10% of reading (1.3×10⁻³–530mbar, 1×10⁻³–400Torr), ±2.5% of reading (530–1333mbar, 400–1000Torr) Repeatability: ±2% of reading Admissible Temperature: Operation: 0–40°C, Storage: -40–70°C, Bakeout: ≤150°C Supply Voltage: +12–+28V(dc) -
PGE500 DeviceNet™
Measurement Range: 1.3×10⁻⁴–1333mbar, 1×10⁻⁴–1000Torr, 1.3×10⁻²–133000Pa Accuracy: ±10% of reading, ±2.5% of reading Repeatability: ±2% of reading Admissible Temperature: Operation: 0–40°C, Storage: -40–70°C, Bakeout: ≤150°C Supply Voltage: +12–+26V(dc) -
PCG55x Atmospheric to Medium Vacuum Gauge
Measurement Range (mbar): 5×10⁻⁵…1500 Measurement Range (Torr): 3.8×10⁻⁵…1125 Accuracy 5×10⁻⁴…1×10⁻³ mbar: ±50% of reading Accuracy 1×10⁻³…100 mbar: ±15% of reading Accuracy 100…950 mbar: ±5% of reading -
PGE300 Pirani Gauge Enhanced
Measurement Range: 1.3×10⁻⁴–1333mbar, 1×10⁻⁴–1000Torr, 1.3×10⁻²–133000Pa Accuracy: 0.1×10⁻³mbar resolution, ±10% of reading, ±2.5 Repeatability: ±2% of reading Admissible Temperature: Operation: 0–40°C, Storage: -40–70°C, Bakeout: ≤70°C Supply Voltage: +12–+28V(dc)