Current Category:
Subcategory:
- 3D Scanner(4)
- Beam Profilers(6)
- Conventional Microscopes(17)
- Displacement Gages(30)
- Sensors(230)
- Fiber Inspection Tools(31)
- Fiber Test & Measurement(120)
- Gas Analysis(48)
- Interferometers(12)
- Laser Scanning and Ranging(4)
- LiDAR(41)
- Material Analysis and Forensics(13)
- Measurement Devices(17)
- Metrology Accessories(43)
- Microscope Accessories(19)
- Microscopes(36)
- Optical Cells(1)
- Optical Inspection(23)
- Optical Metrology(48)
- Optical Power Meters(42)
- Optical Spectrum Analyzers(18)
- Optical Surface Profiler(15)
- Optical Wavelength Meters(7)
- Scanners and Rangefinders(5)
- Size Measurement(18)
- Spectrometers(27)
- Terahertz(11)
- Thermal Solutions(24)
- Waveform Generators and Analyzers(5)
- Other(639)
- Probe Station(49)
- Probe Station Accessories(125)
Country:
More
Brand:
- Exfo
- CasTech
- ColorSpace
- Elite16
- EngWx
- Eoulu
- Fibretop
- Foctek
- GdTumtec
- HbSais
- Hesaitech
- Hoyatek
- Hroptron
- Inficon
- JcNanoControl
- Jjk
- Kaitengtx
- Keyence
- Koc
- KonicaMinolta
- Kyky
- LitraTech
- Micro-Epsilon
- Mvotem
- Opwill
- PhenixOptics
- Santec
- Slamtec
- Sowaysensor
- Steligent
- SymcTec
- Tekcn
- Toptica-China
- Ulirvision
- UlvacShanghai
- Uni-Trend
- Uwlaser
- WaveLabSci
- Wayeal
- Wayho
- WekonTech
- Whhxykj
- WhPrecise
- Xmgttx
- Ybsemi-Solution
- Yokogawa
- Ytdq
- ZcHightech
- ZhVacuum
- ZkTel
- Burkert
- Trumpf
- EdwardsVacuum
Photonics Source provides 1728 products. Download datasheets, request quotes, and compare function, price, and availability.
-
PGE050 Pirani Gauge Enhanced - Passive
Measurement System: Pirani, convection-enhanced Measurement Range: 1.3×10⁻⁴ to 1333mbar, 1×10⁻⁴ to 1000Torr, 1.3×10⁻² to 133000Pa Accuracy: 1.3×10⁻⁴ to 1.3×10⁻³mbar: ±0.1×10⁻³mbar, 1.3×10⁻³ to 530mbar: ±10% of reading, 530 to 1333mbar: ±2.5% of reading Repeatability: ±2% of reading Mounting Orientation: Recommended horizontal -
MAG470 Inverted Magnetron Gauge
Measurement Range (air, N₂): 5×10⁻¹¹ mbar to 1×10⁻² mbar (3.8×10⁻¹¹ Torr to 7.5×10⁻³ Torr) Accuracy (N₂): ±30% of reading Repeatability (N₂): ±5% of reading Mounting Orientation: any Admissible Pressure (absolute): ≤10bar (limited to inert gases) -
MPG40x High Vacuum Gauge
Measurement Range (Air, N₂): 5×10⁻⁹...1000mbar Measurement Range (Air, N₂) Torr: 3.8×10⁻⁹...760 Accuracy (N₂): 1×10⁻⁸...100mbar ±30% Repeatability: 1×10⁻⁸...100mbar ±5% Installation Position: any -
MAG084
Measurement System: cold cathode ionization (inverted magnetron principle) Display Range (Air N2): 5×10^-9mbar to 1×10^-2mbar Measurement Range (Air N2): 1×10^-8mbar to 5×10^-3mbar Accuracy (Air N2): 30% of reading Repeatability (typical): 5% of reading -
MAG050, MAG060, MAG070
Measurement System: Cold cathode ionization (inverted magnetron principle) Measurement Range MAG050: 2×10⁻²...5×10⁻³ mbar Measurement Range MAG060: 1×10⁻¹⁰...5×10⁻³ mbar Measurement Range MAG070: 1×10⁻¹¹...5×10⁻³ mbar Accuracy: 30% of reading -
LDS Arnova
Minimum detectable leak rate (Air): 1×10^-4mbar/s Minimum detectable leak rate (Argon): 1×10^-6mbar/s Units of measurement (options): mbar/s,Pa,m3/s,atmcc/s,g/a,ppm Maximum permissible input pressure: 18mbar (Gross mode), 0.9mbar (Fine mode), 0.2mbar (Ultra mode) Response Time: <1s -
LDM150 and LDM150R Refrigerant Monitors
Model: 743-202-HFC, 743-202-HFCHV, 743-202-CO2, 743-202-CO2HV, 743-202-NH3, 743-202-NH3HV, 743-203-HFC, 743-203-HFCHV, 743-203-CO2, 743-203-CO2HV, 743-203-NH3, 743-203-NH3HV, 743-203-R290, 743-203-R290HV Compatible Refrigerants: R22, R32, R134a, R404a, R407c, R410a, R422b, R448a, R449a, R452a, R452b, R507, AZ50, R1234yf, CO2, Ammonia, R290, R600, R441a Power Input: 230VAC or 12-24V (AC/DC), 50-60Hz Cable Length: Not included (user provided), 5m (16.5ft) Certification: CE, IP54, IP67, IP56, ATEX -
IRwin Methane Leak Detector
Ex Classification: Ex II 1G, Ex ia IIC T3 Ga (Zone 0) Intrinsically safe: Class I, Division 1, Groups B, C and D Detectable gases: Methane Detectable gases: carbon dioxide Detectable gases: ethane -
Multipoint Refrigerant Monitors
Compatible Refrigerants: HFCs Compatible Refrigerants: HCFCs Compatible Refrigerants: HFOs Power Input: 12-24V (AC/DC), 50-60Hz Cable Length: Not included (user provided) -
IRG080 Ion Reference Gauge - Passive
Measurement System: hot cathode ionization Electrode System Configuration: according to ISO TS 6737 Measurement Range (N2): <1×10^-8...1×10^-4mbar, <1×10^-8...1×10^-2Pa Sensitivity (N2, typical): 29mbar^-1 Accuracy (N2, typical): ±1% of reading -
IM540 Vacuum Gauge Controller
Measurement channel: 3 Display: LCD Display: LED backlight Display Rate: 4s⁻¹ Measurement Range IE414 (Bayard-Alpert): 1×10⁻¹¹...1×10⁻²mbar | 0.75×10⁻¹¹...0.75×10⁻²Torr -
IRC081 Ion Reference Gauge Controller
Measurement channel: 1 Measurement rate: 1s⁻¹ User Interface: Front panel, PC-software Manual control: 5 knobs Remote Control: via USB 2.0 with PC software 'IRC081 user interface' -
HPG400 High Pressure Pirani Gauge
Measurement Range (Air, N2): 1.5×10⁻⁶…750Torr Accuracy: ±15% of reading Repeatability: 2% of reading Hot Cathode Emission, Optional: 5×10⁻²…1mbar Optional Component 1: 1mbar -
IE414 & IE514 Sensors
Measurement System: Hot cathode ionization Electrode System Configuration IE414: Bayard-Alpert Electrode System Configuration IE514: Extractor system Measurement Range (N2) IE414: 2×10^-11...1×10^-2mbar Measurement Range (N2) IE514: 2×10^-12...1×10^-4mbar -
Gemini™ MxG5xx
Measurement Range (Air, N2) MAG5xx (mbar): 1×10⁻⁹...1×10⁻² Measurement Range (Air, N2) MPG5xx (mbar): 1×10⁻⁹...1000 Measurement Range (Air, N2) MAG5xx (Torr): 7.6×10⁻¹⁰...7.6×10⁻³ Measurement Range (Air, N2) MPG5xx (Torr): 7.6×10⁻¹⁰...760 Standard Accuracy (N2) MAG5xx: 30% of reading