YC150U Interferometer - Workstation

YC150U Interferometer - Workstation

Supplier
Ycgx
Part Number
YC150U
Category
Interferometers
Origin
China

The YC150U laser interferometer workstation is an upright optical measurement system with a clear aperture of φ152.4 mm, high-precision imaging, and good vibration isolation. It measures surface form and radius of curvature of medium-to-large optical lenses. An enclosed test chamber reduces airflow effects from external factors. A multidimensional motorized sample platform allows optics to lie flat during testing, reducing mounting stress. If the full aperture cannot be tested in one measurement, multiple regions can be measured by adjusting lens pitch according to the actual conditions, as shown below.

Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

The YC150U laser interferometer workstation is an upright optical measurement system with a clear aperture of φ152.4 mm, high-precision imaging, and good vibration isolation. It measures surface form and radius of curvature of medium-to-large optical lenses. An enclosed test chamber reduces airflow effects from external factors. A multidimensional motorized sample platform allows optics to lie flat during testing, reducing mounting stress. If the full aperture cannot be tested in one measurement, multiple regions can be measured by adjusting lens pitch according to the actual conditions, as shown below.

Specifications

ParameterValue
Interferometric Principle [Parameter Image 01: YC150U Workstation Configuration]Fizeau Type
System Accuracy [Parameter Image 01: YC150U Workstation Configuration]Better than λ/20
Effective Beam Diameter [Parameter Image 01: YC150U Workstation Configuration]6 Inches (152.4mm)
Test Wavelength [Parameter Image 01: YC150U Workstation Configuration; Imported He-Ne Laser]632.8 nm
Optical Path Switching [Parameter Image 01: YC150U Workstation Configuration]Electrically Controlled Switching Between Alignment and Testing
Response Frequency [Parameter Image 01: YC150U Workstation Configuration; Source Names/Units Retained]0.5 S
System Inspection Travel [Parameter Image 01: YC150U Workstation Configuration]1250 mm
Standard Spherical Lens Accuracy [Parameter Image 01: YC150U Workstation Configuration; Original @652.8nm Retained Despite Difference from Test Wavelength]λ/10 and λ/15
Standard Plane Lens Accuracy [Parameter Image 01: YC150U Workstation Configuration; @632.8nm]Better than λ/20
Standard Plane Lens Material [Parameter Image 01: YC150U Workstation Configuration]Imported Fused Silica
Material Homogeneity [Parameter Image 01: YC150U Workstation Configuration; Plane Lens]Better than 2
Material Stress [Parameter Image 01: YC150U Workstation Configuration; Plane Lens]Better than 2
PV Repeatability [Parameter Image 01: YC150U Workstation Configuration]<0.01λ
RMS Repeatability [Parameter Image 01: YC150U Workstation Configuration]<0.002λ
Instrument Dimensions [Parameter Image 01: YC150U Workstation Configuration; Length×Width×Height]1740 mm × 1200 mm × 2500 mm
Instrument Weight [Parameter Image 01: YC150U Workstation Configuration]Approximately 1050
Operating Power Supply [Parameter Image 01: YC150U Workstation Configuration]AC100~240V/5A/50/60Hz
Image Analysis [Parameter Image 01: YC150U Workstation Configuration]2/3 Inch; Resolution ≥2K×2K
Image Zoom Mode [Parameter Image 01: YC150U Workstation Configuration]Motorized Continuous Zoom 1~7X
Image Focusing Mode [Parameter Image 01: YC150U Workstation Configuration]Motorized
Interference Fringe Analysis Software (Dynamic) [Parameter Image 01: YC150U Workstation Configuration]Optional
Ambient Vibration Requirements [Parameter Image 01: YC150U Workstation Configuration]Avoid Measurement Environment Vibration of 1~130
Ambient Temperature Requirements [Parameter Image 01: YC150U Workstation Configuration; Preferred]22±2 °C
Ambient Temperature Variation Requirements [Parameter Image 01: YC150U Workstation Configuration]<0.5 °C/h
Ambient Humidity Requirements [Parameter Image 01: YC150U Workstation Configuration; Relative Humidity]50~65 %
Reference mirror radius of curvature [Image 02 Lens Configuration; F-Number=YC150-F0.8]80 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F0.8; Convex Surface]8~80 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F0.8; Concave; Source Gives Only Lower Limit/Hyphen, Upper Limit Not Provided]8–
Maximum measurement aperture [Image 02 Lens Configuration; F-Number=YC150-F0.8; Convex Surface]100 mm
Reference mirror radius of curvature [Image 02 Lens Configuration; F-Number=YC150-F1.1]123.3 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F1.1; Convex Surface]8~123 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F1.1; Concave; Source Gives Only Lower Limit/Hyphen, Upper Limit Not Provided]8–
Maximum measurement aperture [Image 02 Lens Configuration; F-Number=YC150-F1.1; Convex Surface]111 mm
Reference mirror radius of curvature [Image 02 Lens Configuration; F-Number=YC150-F1.5]187 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F1.5; Convex Surface]19~187 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F1.5; Concave; Source Gives Only Lower Limit/Hyphen, Upper Limit Not Provided]19–
Maximum measurement aperture [Image 02 Lens Configuration; F-Number=YC150-F1.5; Convex Surface]125 mm
Reference mirror radius of curvature [Image 02 Lens Configuration; F-Number=YC150-F2.2]290 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F2.2; Convex Surface]12~288 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F2.2; Concave; Source Gives Only Lower Limit/Hyphen, Upper Limit Not Provided]12–
Maximum measurement aperture [Image 02 Lens Configuration; F-Number=YC150-F2.2; Convex Surface]130.9 mm
Reference mirror radius of curvature [Image 02 Lens Configuration; F-Number=YC150-F3.5]475.8 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F3.5; Convex Surface]28~473 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F3.5; Concave; Source Gives Only Lower Limit/Hyphen, Upper Limit Not Provided]28–
Maximum measurement aperture [Image 02 Lens Configuration; F-Number=YC150-F3.5; Convex Surface]135.3 mm
Reference mirror radius of curvature [Image 02 Lens Configuration; F-Number=YC150-F5.4]776.4 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F5.4; Convex Surface]65~775 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F5.4; Concave; Source Gives Only Lower Limit/Hyphen, Upper Limit Not Provided]65–
Maximum measurement aperture [Image 02 Lens Configuration; F-Number=YC150-F5.4; Convex Surface]143 mm
Reference mirror radius of curvature [Image 02 Lens Configuration; F-Number=YC150-F7.2]1045 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F7.2; Convex Surface]92~1043 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F7.2; Concave; Source Gives Only Lower Limit/Hyphen, Upper Limit Not Provided]92–
Maximum measurement aperture [Image 02 Lens Configuration; F-Number=YC150-F7.2; Convex Surface]144.5 mm
Reference mirror radius of curvature [Image 02 Lens Configuration; F-Number=YC150-F15]2271.1 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F15; Convex Surface]205~2270 mm
Radius of curvature measurement range [Image 02 Lens Configuration; F-Number=YC150-F15; Concave; Source Gives Only Lower Limit/Hyphen, Upper Limit Not Provided]205–
Maximum measurement aperture [Image 02 Lens Configuration; F-Number=YC150-F15; Convex Surface]151 mm
Reference mirror radius of curvature [Image 02 Lens Configuration; YC150-TF]PLANE
Maximum measurement aperture [Image 02 Merged Cell for Maximum Concave Aperture; Original Text Retained, Not Treated as Current Vertical Travel]Horizontal Interferometer Measurement Range Is Determined by the Air-Bearing Table Size

Applications

Measures Surface Flatness of High-Precision Plates, Including Glass, Metal, Ceramics, Semiconductor Mask Substrates and LCD Glass, as Well as Convex/Concave Lens Spherical Accuracy, Fringe Count and Transmitted Wavefront.

Key Features

Constant-Temperature Working Chamber, Curvature Measurement, Five-Dimensional Adjustment Stage, Stress-Free Inspection, Compact and Space Saving

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Suzhou Yuchuan Optical Technology Co., Ltd. was established on May 2, 2012, and is currently located in the Changshun Chuanggu Industrial Park, Jinfeng Town, Zhangjiagang City, Jiangsu Province. With decades of working background in foreign enterprises and professional technical strength, the team has always adhered to the service tenet of 'unity, pragmatism, innovation, and trustworthiness' and the quality philosophy of 'excellence based on precision, winning by quality' to keep forging ahead. It has established good cooperative relationships with more than 300 domestic and foreign enterprises. The company specializes in the production and sales of high-precision optical components and optical templates, as well as the R&D, design, production, and sales of optical inspection equipment, providing a one-stop service. The products are applied in fields such as optical parts processing enterprises, projection, image capture, artificial intelligence & industrial equipment, and lighting systems. The company owns multiple imported processing equipment and measuring instruments, ensuring the precision and quality reliability of products.

Request a Quote

Our team responds within 24–48 hours
YC150U Interferometer - Workstation
Ycgx · Interferometers
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →