Inverted Optical Tweezers System STS-IVT

Inverted Optical Tweezers System STS-IVT

Supplier
Jcoptix
Part Number
STS-IVT
Category
Other Measurement Instruments
Origin
China

JCOPTIX inverted optical-tweezers systems comprise laser, illumination, imaging, and motion-control sections. A 532 nm laser traps small particles for XYZ movement. Transmitted Köhler illumination, a domestic 100X plan apochromatic objective, and a right-angle USB3.0 color camera display particle motion in real time during manipulation. Laser sources, illumination, imaging, and stages can be customized; contact technical support. Inverted optical-tweezers system. Model: STS-IVT. Laser: 532 nm, adjustable 0-500 mW. Particle diameters: 1-10 μm. Domestic 100X plan apochromatic objective. Right-angle USB3.0 color camera. Transmitted Köhler illumination. JCOPTIX systems comprise laser, illumination, imaging, and motion control, installed on a standard 450 mm × 600 mm aluminum breadboard with a 66 mm profile-rail support system. The 532 nm laser adjusts up to 500 mW and is conditioned and focused through the objective to trap particles. A differential-screw-driven XY stage provides 0.5 μm operating precision. A coarse/fine Z lift adjusts the focal plane, with minimum fine resolution of 1 μm/division and up to 10 kg load. Transmitted Köhler illumination uniformly illuminates samples. A right-angle USB3.0 color camera (AIC-P133GC-USB) provides imaging; a sliding filter holder switches filtering conveniently. Two objectives are included: a 60X infinity-corrected plan achromatic dry objective, NA=0.85, WD=0.30 mm; and a 100X plan apochromatic oil objective, NA=1.35, WD=0.13 mm. Users select according to the manipulated material.

Specification Snapshot
Laser Wavelength
532 nm
Laser Power
0-500 mW
Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

JCOPTIX inverted optical-tweezers systems comprise laser, illumination, imaging, and motion-control sections. A 532 nm laser traps small particles for XYZ movement. Transmitted Köhler illumination, a domestic 100X plan apochromatic objective, and a right-angle USB3.0 color camera display particle motion in real time during manipulation. Laser sources, illumination, imaging, and stages can be customized; contact technical support. Inverted optical-tweezers system. Model: STS-IVT. Laser: 532 nm, adjustable 0-500 mW. Particle diameters: 1-10 μm. Domestic 100X plan apochromatic objective. Right-angle USB3.0 color camera. Transmitted Köhler illumination. JCOPTIX systems comprise laser, illumination, imaging, and motion control, installed on a standard 450 mm × 600 mm aluminum breadboard with a 66 mm profile-rail support system. The 532 nm laser adjusts up to 500 mW and is conditioned and focused through the objective to trap particles. A differential-screw-driven XY stage provides 0.5 μm operating precision. A coarse/fine Z lift adjusts the focal plane, with minimum fine resolution of 1 μm/division and up to 10 kg load. Transmitted Köhler illumination uniformly illuminates samples. A right-angle USB3.0 color camera (AIC-P133GC-USB) provides imaging; a sliding filter holder switches filtering conveniently. Two objectives are included: a 60X infinity-corrected plan achromatic dry objective, NA=0.85, WD=0.30 mm; and a 100X plan apochromatic oil objective, NA=1.35, WD=0.13 mm. Users select according to the manipulated material.

Specifications

ParameterValue
Laser Wavelength532 nm
Laser Power0-500 mW
Illumination SourceLEM5000K, White Light, Color Temperature: 5000K
CameraAIC-P133GC-USB
ObjectiveIOPASO1514100X-VIS
Tube Lensf=150 mm
Z-Axis Coarse/Fine Adjustment Lifting Stage [Travel 50 mm; Resolution 1 μm; Series Description Specifies Fine Adjustment 1 μm/Division]50 mm, Resolution: 1 μm
XY Sample Stage Travel [Travel 13 mm; Resolution 0.5 μm]Travel: 13 mm, Resolution: 0.5 μm
General Parameters - Sample Stage Travel13 mm

Key Features

Optical Trapping Force Captures Particles; Controls Particle Movement in XYZ Three Axes; Real-Time Camera Display

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Jc
Jcoptix
View Supplier →
Nanjing Jingcui Optical Technology Co., Ltd. (formerly Suzhou Jingcui Optical Technology Co., Ltd., abbreviated as JCOPTIX) is a national high-tech enterprise and a national-level specialized and sophisticated 'little giant' enterprise, established on the foundation of the Liquid Crystal and Photonics Research Center of Nanjing University. It engages in R&D, manufacturing, and sales of advanced optical technologies and products. JCOPTIX is dedicated to building a product platform for China's optical community, offering liquid crystal photonics components, precision optical components, optomechanics, fiber optic assemblies, motion control devices, and system solutions. All listed products can be found and ordered online at www.JCOPTIX.com.

Request a Quote

Our team responds within 24–48 hours
Inverted Optical Tweezers System STS-IVT
Jcoptix · Other Measurement Instruments
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →