Imported Beam Profiler CinCamCMOS-1202

Imported Beam Profiler CinCamCMOS-1202

Supplier
Jcoptix
Part Number
CinCamCMOS-1202
Category
Beam Profilers
Origin
China

JCOPTIX imported beam profilers cover nearly all UV-to-NIR beam-measurement needs, improving product quality, process reliability, and efficiency for laser-spot inspection/testing. Optimized CinCam technology from Germany's CINOGY provides highly sensitive CMOS coverage from UV to near IR. High resolution and small pixels ensure accurate CW/pulsed beam analysis. Plug-and-play design adapts easily to standard optomechanics. Filters, attenuators, and M² instruments are also available. Imported beam profilers. Models: CinCamCMOS-1202, CinCamCMOS-1202-RT, CinCamCMOS-1202-IR, CinCamCMOS-1202-UV, CinCamCMOS-1.001-Nano(S), CinCamCMOS-1.001-Nano(S)-RT, CinCamCMOS-1.001-Nano(S)-IR, CinCamCMOS-1.001-Nano(S)-UV, CinCamCMOS-1.001-Nano(L), CinCamCMOS-1.001-Nano(L)-RT, CinCamCMOS-1.001-Nano(L)-IR, CinCamCMOS-1.001-Nano(L)-UV, CinCamCMOS-3501, CinCamCMOS-3501-RT. Pixel size 4.6-6.4 μm; large sensor dimensions listed as up to 36-27 mm. JCOPTIX supplies German Cinogy CMOS profilers. Large-aperture cameras reach 30 mm for large laser spots, line beams, and highly divergent far-field measurements. Unique CinCam algorithms/technology optimize UV-to-NIR response in CMOS cameras. High resolution/small pixels ensure accurate continuous/pulsed analysis. Universal C/F-Mount interfaces simplify adding attenuating filters, expanders, and UV/IR converters. CinCamCMOS-3501, with aperture exceeding 24 mm, includes full-featured RayCi-Standard software for real-time monitoring, spot size, centroid, ellipticity, normalized relative power, two-/three-dimensional intensity distribution, pointing stability/centroid jitter, power fluctuation curves, and divergence. Data and PDF reports can be exported for routine measurements. M² systems. Models: CS200-FB-LP, CS200-FB-HP, CS300-HP. Compact robust systems requiring no assembly; up to 6 focusing lenses for wide M² range; 2D/3D Gaussian fitting; optional large spots 24 mm at 1/e2 or 14 mm FWHM; CW/pulsed compatibility; accuracy 2~3%; fast measurement 20~40 s. Cinogy professional M² systems include focusing optics, precision automated rails, and CinCam CCD/CMOS/InGaAs cameras. RayCi automatically controls/tracks the entire analysis for accuracy and precision, calculating spot sizes at different caustic planes to ISO 11146-1/2. RayCi-Pro measures M², K, waist size/location, divergence, and Rayleigh length. Visualization, extensive analysis, and advanced algorithms ensure precise, accurate beam-quality measurement. Technical notes: camera-based CinCamCMOS profilers directly capture profiles and analyze two-dimensional energy distributions, including Gaussian-like, flat-top, annular, and irregular patterns. Besides CW beams, synchronous triggering measures pulsed and single-pulse beams. High-value CinCamCMOS basic models combine economical cameras and free basic software for most users, particularly industrial production-line setup/calibration, basic research, and low-power measurements. Download the instructions below for details.

Specification Snapshot
Operating Wavelength
400-1320 nm
Bit Depth
8 Bit
Dynamic Range
62 dB
Weight
50 g
Storage Temperature
-10 - +60 ℃
Operating Temperature
-10 - +40 ℃
Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

JCOPTIX imported beam profilers cover nearly all UV-to-NIR beam-measurement needs, improving product quality, process reliability, and efficiency for laser-spot inspection/testing. Optimized CinCam technology from Germany's CINOGY provides highly sensitive CMOS coverage from UV to near IR. High resolution and small pixels ensure accurate CW/pulsed beam analysis. Plug-and-play design adapts easily to standard optomechanics. Filters, attenuators, and M² instruments are also available. Imported beam profilers. Models: CinCamCMOS-1202, CinCamCMOS-1202-RT, CinCamCMOS-1202-IR, CinCamCMOS-1202-UV, CinCamCMOS-1.001-Nano(S), CinCamCMOS-1.001-Nano(S)-RT, CinCamCMOS-1.001-Nano(S)-IR, CinCamCMOS-1.001-Nano(S)-UV, CinCamCMOS-1.001-Nano(L), CinCamCMOS-1.001-Nano(L)-RT, CinCamCMOS-1.001-Nano(L)-IR, CinCamCMOS-1.001-Nano(L)-UV, CinCamCMOS-3501, CinCamCMOS-3501-RT. Pixel size 4.6-6.4 μm; large sensor dimensions listed as up to 36-27 mm. JCOPTIX supplies German Cinogy CMOS profilers. Large-aperture cameras reach 30 mm for large laser spots, line beams, and highly divergent far-field measurements. Unique CinCam algorithms/technology optimize UV-to-NIR response in CMOS cameras. High resolution/small pixels ensure accurate continuous/pulsed analysis. Universal C/F-Mount interfaces simplify adding attenuating filters, expanders, and UV/IR converters. CinCamCMOS-3501, with aperture exceeding 24 mm, includes full-featured RayCi-Standard software for real-time monitoring, spot size, centroid, ellipticity, normalized relative power, two-/three-dimensional intensity distribution, pointing stability/centroid jitter, power fluctuation curves, and divergence. Data and PDF reports can be exported for routine measurements. M² systems. Models: CS200-FB-LP, CS200-FB-HP, CS300-HP. Compact robust systems requiring no assembly; up to 6 focusing lenses for wide M² range; 2D/3D Gaussian fitting; optional large spots 24 mm at 1/e2 or 14 mm FWHM; CW/pulsed compatibility; accuracy 2~3%; fast measurement 20~40 s. Cinogy professional M² systems include focusing optics, precision automated rails, and CinCam CCD/CMOS/InGaAs cameras. RayCi automatically controls/tracks the entire analysis for accuracy and precision, calculating spot sizes at different caustic planes to ISO 11146-1/2. RayCi-Pro measures M², K, waist size/location, divergence, and Rayleigh length. Visualization, extensive analysis, and advanced algorithms ensure precise, accurate beam-quality measurement. Technical notes: camera-based CinCamCMOS profilers directly capture profiles and analyze two-dimensional energy distributions, including Gaussian-like, flat-top, annular, and irregular patterns. Besides CW beams, synchronous triggering measures pulsed and single-pulse beams. High-value CinCamCMOS basic models combine economical cameras and free basic software for most users, particularly industrial production-line setup/calibration, basic research, and low-power measurements. Download the instructions below for details.

Specifications

ParameterValue
Operating Wavelength400-1320 nm
Pixel Size5.3 μm × 5.3 μm
Beam Diameter min/max [Before Slash: Minimum Spot Diameter in μm; After Slash: Maximum Spot Diameter in mm; Units Not Converted or Combined]53 μm/4.1 mm
Bit Depth8 Bit
Dynamic Range62 dB
Mounting InterfaceF-Mount
Mechanical Dimensions40 mm × 40 mm × 20 mm
Weight50 g
Storage Temperature-10 - +60 ℃
Operating Temperature-10 - +40 ℃
Laser ModeContinuous and Pulsed
Power Supply InterfaceUSB 2.0
Clear Aperture Dimension6.8 mm × 5.4 mm
Resolution1280 × 1024

Key Features

UV-to-Near-Infrared Coverage; High Resolution and Small Pixels; High-Precision CW and Pulsed Laser Beam Analysis; Compatible with Various Attenuators and CinSquare M² Measurement Instruments.

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Jc
Jcoptix
View Supplier →
Nanjing Jingcui Optical Technology Co., Ltd. (formerly Suzhou Jingcui Optical Technology Co., Ltd., abbreviated as JCOPTIX) is a national high-tech enterprise and a national-level specialized and sophisticated 'little giant' enterprise, established on the foundation of the Liquid Crystal and Photonics Research Center of Nanjing University. It engages in R&D, manufacturing, and sales of advanced optical technologies and products. JCOPTIX is dedicated to building a product platform for China's optical community, offering liquid crystal photonics components, precision optical components, optomechanics, fiber optic assemblies, motion control devices, and system solutions. All listed products can be found and ordered online at www.JCOPTIX.com.

Request a Quote

Our team responds within 24–48 hours
Imported Beam Profiler CinCamCMOS-1202
Jcoptix · Beam Profilers
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →