Photoelectric Autocollimator NORMAT1210

Photoelectric Autocollimator NORMAT1210

Supplier
Jcoptix
Part Number
NORMAT1210
Category
Optical Metrology
Origin
China

JCOPTIX offers NORMAT photoelectric autocollimators with accuracy up to ±0.01″, single-measurement distances beyond 25 meters, and stitched straightness measurements of unlimited rail length. Preferred for precision manufacturing/optical assembly, they use computer USB power without extra supply cabling. Special optics/high-sensitivity sensors measure reflecting surfaces as small as Ø3mm, with resolution up to 0.001″. Stable cold sources avoid thermal drift and are portable/replaceable for easy maintenance. Simultaneous X/Y angles convert to linear values for live straightness updates. NORMAT software supports wireless single-operator control, multiple targets, data output, relative/absolute modes, and minimum-zone/least-squares straightness algorithms. Adjustable display resolutions are 0.0001, 0.001, 0.01, 0.1, 1. Stitching removes distance limits. All data displays/records live and exports to .csv with one click. Open communication supports LabVIEW/C development and automated inspection integration. Applications include precision manufacturing, research, aerospace, angle, straightness, and flatness measurement. Photoelectric autocollimators. Models: NORMAT1110, NORMAT1210, NORMAT1230, NORMAT1310, NORMAT2210, NORMAT2230, NORMAT2310, NORMAT3210, NORMAT3230, NORMAT3310, NORMAT3330, NORMAT4310, NORMAT4330, NORMAT5330, NORMAT5330P, NORMAT5510, NORMAT6310, NORMAT6330. Accuracy up to ±0.01″. Resolution up to 0.001″. Simultaneous X/Y measurement with real-time linear conversion. LabVIEW/C development compatible. JCOPTIX NORMAT units offer ±0.01″ accuracy, 0.001″ resolution, and ultralarge fields for precision manufacturing/optical assembly. Manufacturer inspection reports are supplied; contact support for metrology-institute reports or special requirements.

Specification Snapshot
Accuracy
±1″
Repeatability
0.2″
Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

JCOPTIX offers NORMAT photoelectric autocollimators with accuracy up to ±0.01″, single-measurement distances beyond 25 meters, and stitched straightness measurements of unlimited rail length. Preferred for precision manufacturing/optical assembly, they use computer USB power without extra supply cabling. Special optics/high-sensitivity sensors measure reflecting surfaces as small as Ø3mm, with resolution up to 0.001″. Stable cold sources avoid thermal drift and are portable/replaceable for easy maintenance. Simultaneous X/Y angles convert to linear values for live straightness updates. NORMAT software supports wireless single-operator control, multiple targets, data output, relative/absolute modes, and minimum-zone/least-squares straightness algorithms. Adjustable display resolutions are 0.0001, 0.001, 0.01, 0.1, 1. Stitching removes distance limits. All data displays/records live and exports to .csv with one click. Open communication supports LabVIEW/C development and automated inspection integration. Applications include precision manufacturing, research, aerospace, angle, straightness, and flatness measurement. Photoelectric autocollimators. Models: NORMAT1110, NORMAT1210, NORMAT1230, NORMAT1310, NORMAT2210, NORMAT2230, NORMAT2310, NORMAT3210, NORMAT3230, NORMAT3310, NORMAT3330, NORMAT4310, NORMAT4330, NORMAT5330, NORMAT5330P, NORMAT5510, NORMAT6310, NORMAT6330. Accuracy up to ±0.01″. Resolution up to 0.001″. Simultaneous X/Y measurement with real-time linear conversion. LabVIEW/C development compatible. JCOPTIX NORMAT units offer ±0.01″ accuracy, 0.001″ resolution, and ultralarge fields for precision manufacturing/optical assembly. Manufacturer inspection reports are supplied; contact support for metrology-institute reports or special requirements.

Specifications

ParameterValue
Accuracy±1″
Number of Measurement AxesSimultaneous X/Y Dual-Axis Measurement (Convertible to Straightness in Real Time)
Field of View [H × V]3800″ × 2800″(H × V)
Resolution0.1″
Repeatability0.2″
Objective Focal Length200 mm
Objective Aperture38.1 mm
Minimum Reflecting Surface [K9 Material, Without Reflective Coating]Ø3 mm (K9 Material, Without Reflective Coating)
Light Source Type [LED Center Wavelength λ=630 nm; Field Represents Light Source Type]LED (Center Wavelength λ=630 nm)
Computer InterfaceUSB3.0
Measurement Frequency Response25 Hz
Measurement ControlPC Buttons, zhunshijian-Triggered Measurement (Source Wording), Remote-Controlled Measurement
Power SupplyUSB Powered
Single Measurement Distance≥ 10 m
Stitched Measurement DistanceInfinity

Key Features

Accuracy up to ±0.01″, Resolution up to 0.001″; Simultaneous X,Y Angular Measurement with Real-Time Conversion to Linear Values; Compatible with LabVIEW, C and Other Secondary Development Environments.

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Jc
Jcoptix
View Supplier →
Nanjing Jingcui Optical Technology Co., Ltd. (formerly Suzhou Jingcui Optical Technology Co., Ltd., abbreviated as JCOPTIX) is a national high-tech enterprise and a national-level specialized and sophisticated 'little giant' enterprise, established on the foundation of the Liquid Crystal and Photonics Research Center of Nanjing University. It engages in R&D, manufacturing, and sales of advanced optical technologies and products. JCOPTIX is dedicated to building a product platform for China's optical community, offering liquid crystal photonics components, precision optical components, optomechanics, fiber optic assemblies, motion control devices, and system solutions. All listed products can be found and ordered online at www.JCOPTIX.com.

Request a Quote

Our team responds within 24–48 hours
Photoelectric Autocollimator NORMAT1210
Jcoptix · Optical Metrology
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →