Specification Snapshot
Operating Wavelength
1260–1650 nm
Operating Temperature
−40 to +85 ℃
Storage Temperature
−40 to +85 ℃
Insertion Loss [Port Configuration 1×2]
typical:3.7 dB; max:4.0 dB
Return Loss [Port Configuration 1×2]
min:50 dB
Polarization Dependent Loss [Port Configuration 1×2]
max:0.2 dB
Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

Optical fiber access systems; local, wide and metropolitan area networks; passive analog/digital optical networks; other optical fiber systems.

Specifications

ParameterValue
Fiber TypeSMF-28e or custom
Operating Wavelength1260–1650 nm
Operating Temperature−40 to +85 ℃
Storage Temperature−40 to +85 ℃
Insertion Loss [Port Configuration 1×2]typical:3.7 dB; max:4.0 dB
Insertion Loss Uniformity [Port Configuration 1×2]max:0.4 dB
Return Loss [Port Configuration 1×2]min:50 dB
Polarization Dependent Loss [Port Configuration 1×2]max:0.2 dB
Directivity [Port Configuration 1×2]min:55 dB
Wavelength Dependent Loss [Port Configuration 1×2]max:0.3 dB
Temperature-Dependent Loss [Port configuration 1×2; −40 to +85℃; No loss unit stated in the original row]max:0.5
Insertion Loss [Port Configuration 1×4]typical:6.8 dB; max:7.2 dB
Insertion Loss Uniformity [Port Configuration 1×4]max:0.6 dB
Return Loss [Port Configuration 1×4]min:50 dB
Polarization Dependent Loss [Port Configuration 1×4]max:0.2 dB
Directivity [Port Configuration 1×4]min:55 dB
Wavelength Dependent Loss [Port Configuration 1×4]max:0.3 dB
Temperature-Dependent Loss [Port configuration 1×4; −40 to +85℃; No loss unit stated in the original row]max:0.5
Insertion Loss [Port Configuration 1×8]typical:10.0 dB; max:10.5 dB
Insertion Loss Uniformity [Port Configuration 1×8]max:0.8 dB
Return Loss [Port Configuration 1×8]min:50 dB
Polarization Dependent Loss [Port Configuration 1×8]max:0.3 dB
Directivity [Port Configuration 1×8]min:55 dB
Wavelength Dependent Loss [Port Configuration 1×8]max:0.3 dB
Temperature-Dependent Loss [Port configuration 1×8; −40 to +85℃; No loss unit stated in the original row]max:0.5
Insertion Loss [Port Configuration 1×16]typical:13.0 dB; max:13.5 dB
Insertion Loss Uniformity [Port Configuration 1×16]max:1.2 dB
Return Loss [Port Configuration 1×16]min:50 dB
Polarization Dependent Loss [Port Configuration 1×16]max:0.3 dB
Directivity [Port Configuration 1×16]min:55 dB
Wavelength Dependent Loss [Port Configuration 1×16]max:0.5 dB
Temperature-Dependent Loss [Port configuration 1×16; −40 to +85℃; No loss unit stated in the original row]max:0.8
Insertion Loss [Port Configuration 1×32]typical:16.0 dB; max:16.9 dB
Insertion Loss Uniformity [Port Configuration 1×32]max:1.5 dB
Return Loss [Port Configuration 1×32]min:50 dB
Polarization Dependent Loss [Port Configuration 1×32]max:0.3 dB
Directivity [Port Configuration 1×32]min:55 dB
Wavelength Dependent Loss [Port Configuration 1×32]max:0.5 dB
Temperature-Dependent Loss [Port configuration 1×32; −40 to +85℃; No loss unit stated in the original row]max:0.8
Insertion Loss [Port Configuration 1×64]typical:19.5 dB; max:21.0 dB
Insertion Loss Uniformity [Port Configuration 1×64]max:2.5 dB
Return Loss [Port Configuration 1×64]min:50 dB
Polarization Dependent Loss [Port Configuration 1×64]max:0.4 dB
Directivity [Port Configuration 1×64]min:55 dB
Wavelength Dependent Loss [Port Configuration 1×64]max:0.8 dB
Temperature-Dependent Loss [Port configuration 1×64; −40 to +85℃; No loss unit stated in the original row]max:1.0
Insertion Loss [Port Configuration 2×2]typical:3.8 dB; max:4.2 dB
Insertion Loss Uniformity [Port Configuration 2×2]max:1.0 dB
Return Loss [Port Configuration 2×2]min:50 dB
Polarization Dependent Loss [Port Configuration 2×2]max:0.2 dB
Directivity [Port Configuration 2×2]min:55 dB
Wavelength Dependent Loss [Port Configuration 2×2]max:0.8 dB
Temperature-Dependent Loss [Port configuration 2×2; −40 to +85℃; No loss unit stated in the original row]max:0.5
Insertion Loss [Port Configuration 2×4]typical:7.4 dB; max:7.8 dB
Insertion Loss Uniformity [Port Configuration 2×4]max:1.4 dB
Return Loss [Port Configuration 2×4]min:50 dB
Polarization Dependent Loss [Port Configuration 2×4]max:0.2 dB
Directivity [Port Configuration 2×4]min:55 dB
Wavelength Dependent Loss [Port Configuration 2×4]max:0.8 dB
Temperature-Dependent Loss [Port configuration 2×4; −40 to +85℃; No loss unit stated in the original row]max:0.5
Insertion Loss [Port Configuration 2×8]typical:10.8 dB; max:11.2 dB
Insertion Loss Uniformity [Port Configuration 2×8]max:1.5 dB
Return Loss [Port Configuration 2×8]min:50 dB
Polarization Dependent Loss [Port Configuration 2×8]max:0.4 dB
Directivity [Port Configuration 2×8]min:55 dB
Wavelength Dependent Loss [Port Configuration 2×8]max:0.8 dB
Temperature-Dependent Loss [Port configuration 2×8; −40 to +85℃; No loss unit stated in the original row]max:0.5
Insertion Loss [Port Configuration 2×16]typical:14.2 dB; max:14.6 dB
Insertion Loss Uniformity [Port Configuration 2×16]max:2.0 dB
Return Loss [Port Configuration 2×16]min:50 dB
Polarization Dependent Loss [Port Configuration 2×16]max:0.4 dB
Directivity [Port Configuration 2×16]min:55 dB
Wavelength Dependent Loss [Port Configuration 2×16]max:0.8 dB
Temperature-Dependent Loss [Port configuration 2×16; −40 to +85℃; No loss unit stated in the original row]max:0.8
Insertion Loss [Port Configuration 2×32]typical:17.0 dB; max:17.5 dB
Insertion Loss Uniformity [Port Configuration 2×32]max:2.5 dB
Return Loss [Port Configuration 2×32]min:50 dB
Polarization Dependent Loss [Port Configuration 2×32]max:0.4 dB
Directivity [Port Configuration 2×32]min:55 dB
Wavelength Dependent Loss [Port Configuration 2×32]max:0.8 dB
Temperature-Dependent Loss [Port configuration 2×32; −40 to +85℃; No loss unit stated in the original row]max:0.8
Insertion Loss [Port Configuration 2×64]typical:21.0 dB; max:21.5 dB
Insertion Loss Uniformity [Port Configuration 2×64]max:2.5 dB
Return Loss [Port Configuration 2×64]min:50 dB
Polarization Dependent Loss [Port Configuration 2×64]max:0.5 dB
Directivity [Port Configuration 2×64]min:55 dB
Wavelength Dependent Loss [Port Configuration 2×64]max:1.0 dB
Temperature-Dependent Loss [Port configuration 2×64; −40 to +85℃; No loss unit stated in the original row]max:1.0

Key Features

Low insertion loss and low polarization-dependent loss; high channel counts; excellent reliability and stability; wide operating wavelength range; wide operating temperature range; compact dimensions.

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Wa
Wanshuo
View Supplier →
Shandong Wanshuo Optoelectronic Equipment Co., Ltd. was established in April 2008. It is a fiber amplifier manufacturer and fiber transmission solution provider in the communications industry. It provides forward-looking, cost-effective fiber amplifiers to countries around the world and customized development services for the communications industry. With customer experience as the core, it is committed to creating greater industrial value for customers. With the industry's independent core technology, sustainable R&D capabilities and strong production capacity, we are able to tailor multi-series segmented products and solutions for users according to the fiber optic network transmission needs and application characteristics involved in communication networks in different countries and regions. Our products and solutions are being used in the communications fields of various countries and have been widely used in many projects in Russia, South America, Southeast Asia and China. Shandong Wanshuo adheres to the corporate cultural philosophy of "respect, passion, persistence, innovation", takes being a messenger of smart and healthy optical transmission as its vision, and is determined to become a respected, well-known professional company and a leader in the optical transmission industry, providing more customers with satisfactory user experience and customized services.

Request a Quote

Our team responds within 24–48 hours
WS-box-type PLC optical fiber splitter
Wanshuo · Communications & Energy
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →