BeamMap2 Collimate Multiplane Slit-Scanning Beam Profiler
BeamMap2 represents a completely different approach to real-time beam profiling. It extends the measurement capabilities of Beam'R2 to multiple locations along the beam path. This real-time scanning-slit system uses pairs of XY slits in multiple Z planes on a rotating disk to simultaneously measure four beam profiles at four different Z positions. BeamMap2's unique design is particularly advantageous for real-time measurement of focal position, M², beam divergence, and pointing. Compared with the standard BeamMap2, BeamMap2 Collimate is specially designed with plane spacing significantly increased by 5 mm for well-collimated beams.
Overview
Specifications
| Parameter | Value |
|---|---|
| Wavelengths [Si Detector] | 190 至 1150 nm |
| Wavelengths [InGaAs Detector] | 650 至 1800 nm |
| Wavelengths [Si + InGaAs Detector] | 190 至 1800 nm |
| Wavelengths [Si + InGaAs (extended) detector] | 190 to 2300 or 2500 nm |
| Scanning Beam Diameter [Si Detector] | 5 µm to 4 mm |
| Scanning Beam Diameter [InGaAs Detector] | 10 µm to 3 mm |
| Scanning Beam Diameter [Extended InGaAs detector] | 10 µm to 2 mm |
| Plane Spacing | 5 mm: -5, 0, +5, +20 mm |
| Beam Waist Diameter Measurement | Second-moment (4s) diameter compliant with ISO 11146; fitted Gaussian and TopHat; 1/e² (13.5%) width; user-selectable peak percentage |
| Beam Waist Position Measurement | Best ± 20 µm along the X, Y, and Z axes — contact us for advice |
| Measurement Source | Continuous and quasi-continuous beams |
| Resolution Accuracy | 0.1 µm or 0.05% of the scan range; ± < 2% ± = 0.5 µm |
| M² Measurement [±5%] | 1 to > 20 |
| Divergence/Collimation, Pointing | Best 1 mrad — contact us for advice |
| Maximum Power [Total] | 1 W |
| Maximum Irradiance | 0.5 mW/µm² |
| Gain Range | 1‚000:1 Switch ;4‚096:1 ADC Range |
| Displayed Graphs | XY positions and profiles, zoom x1 to x16 |
| Update Rate | ~5 Hz, adjustable from 2 to 10 Hz |
| Pass/Fail Display | Selectable pass/fail colors on screen. Ideal for QA and production. |
| Averaging | User-selectable running average (1 to 8 samples) |
| Statistics | Minimum, maximum, mean, standard deviation; records data over longer periods |
| XY Profiles and Centroid | Beam drift display and recording |
| Minimum Requirements | Windows 10 64 bits |
Applications
Key Features
Datasheet
Please provide your email to download the datasheet.
Invalid email format. Please try again.