hurrySCAN II Series Small-Aperture High-Speed High-Precision Scanning Galvanometer hurrySCAN II 7
The hurrySCAN II series is intended for industrial laser scanning processes. This model uses an analog position detector and analog servo-control board for rapid marking and coding, fine-pattern scanning, microhole and microstructure machining, and dynamic in-line processing of moving workpieces. Note:18 bit resolution is calculated over the full angular range, approximately2.8 µrad at±0.36 rad; resolution better than16 bit (11 µrad) requires the SL2-100 interface. System-integration reference: Laser | Select according to material, wavelength, power, and process. hurrySCAN II scan head | Select according to incident beam diameter, dynamic performance, and accuracy. F-Theta scan lens | Select according to working distance, processing field, wavelength, and target spot. RTC control board | Select according to scanner interface, control requirements, and software compatibility. laserDESK software | Processing jobs and scanning control for compatible SCANLAB scanning systems. Three-axis extensions and auxiliary components | Evaluate varioSCAN II when Z-axis dynamic focusing is required; consider camera adapters, distance sensors, auxiliary lighting, and protective components as needed.
Overview
Specifications
| Parameter | Value |
|---|---|
| Clear Aperture (Entrance Aperture) | 7 mm |
| Position Sensing Method | Analog position detector |
| Standard Coating (Wavelength Range) | YAG and fiber, green, UV, CO2 lasers |
| Optional Coatings | Multiwavelength, broadband, short-pulse, and polarization-maintaining coatings |
| Maximum Laser Power [Standard system; 100% duty cycle; 1064 nm] | 100 W @ 1064 nm |
| Typical Scan Angle [Optical angle] | ±0.35 rad (optical angle) |
| Scan Field Size | 65 mm × 65 mm |
| Typical Spot Size | 46 µm |
| Number of Preinstalled Tuning Modes | 1 type |
| Typical Tuning Modes | Fast vector tuning |
| Tracking Error | 0.11 ms |
| Marking Speed | 3.5 m/s |
| Positioning Speed | 15.0 m/s |
| Writing Speed (High-Quality Mode) | 800 cps |
| Writing Speed (Good-Quality Mode) | 1100 cps |
| Step Response Time [1% full scale] | 0.23 ms |
| Repeatability [RMS] | < 2 µrad |
| Maximum Positioning Resolution [Full angular range; approximately 2.8 µrad at ±0.36 rad; resolution better than 16 bit (11 µrad) requires the SL2-100 interface] | 18 bit |
| Nonlinearity [44°] | < 3.5 mrad / 44° |
| Gain Error | < 5 mrad |
| Zero Offset Error | < 5 mrad |
| Servo Control | Analog servo control board |
| Control Interface | Digital: SL2-100, XY2-100 (standard); analog: ±4.8 V, ±9.6 V |
| Advanced Diagnostics | Not Supported |
| Power Supply Requirements | ±(15 + 1.5) V DC, maximum 3 A |
| Scanning Axes | 2-axis system |
| Housing Type | Standard: scanning galvanometer; optional: modular structure without housing |
| Connector Position | Beam entrance side; optional: opposite side at the beam exit |
| Weight (Without Field Lens, Standard Housing) | ~ 3 kg |
| Dimensions (L × W × H, Standard Housing) | 175 mm × 114 mm × 147 mm |
| Beam Offset | 9.98 mm |
| Water Cooling | Not Supported |
| Air Cooling | Not Supported |
| Operating Temperature | 25 °C ± 10 °C |