Cooled Fiber-Optic Spectrometers NOVA2S

Cooled Fiber-Optic Spectrometers NOVA2S

Supplier
Ideaoptics
Part Number
NOVA2S
Category
Spectrometers
Origin
China

The NOVA cooled fiber spectrometer incorporates internal thermoelectric cooling and a high-resolution optical platform, combining high resolution and low noise. It is especially suitable for weak-light detection requiring long exposure, such as fluorescence and Raman signal detection.

Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

The NOVA cooled fiber spectrometer incorporates internal thermoelectric cooling and a high-resolution optical platform, combining high resolution and low noise. It is especially suitable for weak-light detection requiring long exposure, such as fluorescence and Raman signal detection.

Specifications

ParameterValue
Spectral Model - Spacing0.56 nm
Spectral Model - Spacing0.38 nm
Spectral Model - Spacing0.37 nm
Spectral Model - Spacing0.35 nm
Spectral Model - Spacing0.18 nm
Spectral Model - Resolution [10μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]1.23 nm
Spectral Model - Resolution [10μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]0.84 nm
Spectral Model - Resolution [10μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]0.82 nm
Spectral Model - Resolution [10μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]0.78 nm
Spectral Model - Resolution [10μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]0.41 nm
Spectral Model - Resolution [25μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]1.45 nm
Spectral Model - Resolution [25μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]0.99 nm
Spectral Model - Resolution [25μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]0.97 nm
Spectral Model - Resolution [25μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]0.92 nm
Spectral Model - Resolution [25μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]0.48 nm
Spectral Model - Resolution [50μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]1.84 nm
Spectral Model - Resolution [50μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]1.26 nm
Spectral Model - Resolution [50μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]1.23 nm
Spectral Model - Resolution [50μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]1.16 nm
Spectral Model - Resolution [50μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]0.61 nm
Spectral Model - Resolution [100μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]2.62 nm
Spectral Model - Resolution [100μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]1.79 nm
Spectral Model - Resolution [100μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]1.74 nm
Spectral Model - Resolution [100μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]1.66 nm
Spectral Model - Resolution [100μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]0.87 nm
Spectral Model - Resolution [200μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]4.95 nm
Spectral Model - Resolution [200μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]3.39 nm
Spectral Model - Resolution [200μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]3.30 nm
Spectral Model - Resolution [200μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]3.13 nm
Spectral Model - Resolution [200μm Slit ; typical , Actually Permitted 20% Deviation ;FWHM]1.65 nm
Spectral Performance - Detection Range [Depends on the grating]200~1100nm,具体视光栅而定
Spectral Performance - Wavelength Resolution [Based on a 1200-line grating]As fine as 0.18nm, based on a 1200-line grating; see Technical Parameters for details
Spectral Performance - Optical Resolution [Based on a 1200-line grating and a 10μm slit]As fine as 0.41nm (FWHM), based on a 1200-line grating and a 10μm slit; see Technical Parameters for details
Spectral Performance - DetectorHamamatsu, 1044×64 pixels, cooled area-array back-illuminated CCD, peak quantum efficiency 95%
Spectral Performance - Higher-Order Diffraction Elimination3 front and 4 rear filter options to eliminate ghost lines in the spectrum
Spectral Performance - Optical BenchFocal length 100mm, f-number 4.5, symmetric crossed C-T optical path
Spectral Performance - Integration Time4ms ~ 15min
Spectral Performance - Dynamic Range10,000:1
Spectral Performance - Signal-to-Noise Ratio [At saturation]1,000:1, at saturation
Spectral Performance - Stray Light [600nm ( typical )]<0.1% @ 600nm ( typical )
Spectral Performance - Corrected Linearity99%
External Interfaces - Fiber InterfaceSMA905
External Interfaces - Data TransmissionUSB2.0, RS232
External Interfaces - Expansion Function Port30 pin expansion port, supports BreakOut-Board external expansion
External Interfaces - External Trigger4 trigger modes: Normal / Level / Edge / Synchronization
Other - Dimensions195 mm³ × 120 mm³ × 45 mm³
Other - Weight1.2kg
Other - A/D Bit Depth16-bit
Other - Power Consumption3A @ 5VDC
Other-Cooling RangeSingle-stage on-chip TEC cooling

Applications

Fluorescence/Raman spectroscopy: fluorescence is typically one order of magnitude weaker than excitation, requiring high-sensitivity fiber spectrometers; even weaker Raman signals generally require long exposures. Absorption spectroscopy: sample and reference intensities can differ by 3 orders of magnitude, requiring signal-to-noise ratio above 1000:1. Microspectroscopy: collection from micrometer-scale regions requires weak-light detection. Angle-resolved spectroscopy: signals split among angles and collected individually require weak-light sensitivity and high-speed acquisition.

Key Features

Signal-to-noise ratio up to 1000:1: the NOVA cooled fiber spectrometer uses a Hamamatsu internally thermoelectrically cooled detector and excellent electronics to lower operating temperature by 40℃ below ambient, suppressing dark-current noise. Peak quantum efficiency 95%: special backside thinning admits light through the back of the detector into the PN junction, improving quantum efficiency, especially in the ultraviolet. Strong product performance: complex engineering combines spectroscopy, electronics, and structural design.

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Id
Ideaoptics
View Supplier →
Shanghai Ideaoptics Co., Ltd. is a national-level specialized and sophisticated 'Little Giant' enterprise, a deep-spectrum technology innovator. Devoted to the micro-nano optoelectronic field, it develops intelligent full-spectrum technology integrating photonics and AI, building an internationally leading deep-spectrum platform. The company provides comprehensive solutions from technology to products, including micro spectrometers, angle-resolved spectrometers, and confocal Raman spectrometers, widely applied in IC chips, optical chips, biochips, AR/VR, and advanced displays. Through joint R&D centers with universities, Ideaoptics continuously launches breakthrough products, serving over 3,000 customers and cooperating with 170+ semiconductor, advanced materials, and biomedical enterprises, aiming to advance photonic integration and empower semiconductor manufacturing.

Request a Quote

Our team responds within 24–48 hours
Cooled Fiber-Optic Spectrometers NOVA2S
Ideaoptics · Spectrometers
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →