High-Speed High-Resolution Spectrometers BZ4000
The BLAZE plasma spectrometer uses a CMOS detector and supports a multichannel design, with high resolution as fine as 0.06nm to resolve closely spaced spectral features. Nanosecond-precise timing control avoids pulsed-laser and continuous radiation, detecting strong atomic spectral signals around 1μs after excitation. This benefits trace-element detection and is well suited to LIBS applications.
Request a Quote
Download Datasheet
Overview
The BLAZE plasma spectrometer uses a CMOS detector and supports a multichannel design, with high resolution as fine as 0.06nm to resolve closely spaced spectral features. Nanosecond-precise timing control avoids pulsed-laser and continuous radiation, detecting strong atomic spectral signals around 1μs after excitation. This benefits trace-element detection and is well suited to LIBS applications.
Specifications
| Parameter | Value |
|---|---|
| Interval | 0.02 |
| Interval | 0.03 |
| Interval | 0.04 |
| Interval | 0.05 |
| Interval | 0.07 |
| Resolution [10μm Slit ; typical , Actually Permitted 20% Deviation] | 0.05 |
| Resolution [10μm Slit ; typical , Actually Permitted 20% Deviation] | 0.07 |
| Resolution [10μm Slit ; typical , Actually Permitted 20% Deviation] | 0.08 |
| Resolution [10μm Slit ; typical , Actually Permitted 20% Deviation] | 0.09 |
| Resolution [10μm Slit ; typical , Actually Permitted 20% Deviation] | 0.16 |
| Resolution [10μm Slit ; typical , Actually Permitted 20% Deviation] | 0.21 |
| Resolution [25μm Slit ; typical , Actually Permitted 20% Deviation] | 0.09 |
| Resolution [25μm Slit ; typical , Actually Permitted 20% Deviation] | 0.10 |
| Resolution [25μm Slit ; typical , Actually Permitted 20% Deviation] | 0.14 |
| Resolution [25μm Slit ; typical , Actually Permitted 20% Deviation] | 0.18 |
| Resolution [25μm Slit ; typical , Actually Permitted 20% Deviation] | 0.31 |
| Resolution [25μm Slit ; typical , Actually Permitted 20% Deviation] | 0.38 |
| Resolution [50μm Slit ; typical , Actually Permitted 20% Deviation] | 0.17 |
| Resolution [50μm Slit ; typical , Actually Permitted 20% Deviation] | 0.25 |
| Resolution [50μm Slit ; typical , Actually Permitted 20% Deviation] | 0.33 |
| Resolution [50μm Slit ; typical , Actually Permitted 20% Deviation] | 0.32 |
| Resolution [50μm Slit ; typical , Actually Permitted 20% Deviation] | 0.52 |
| Resolution [50μm Slit ; typical , Actually Permitted 20% Deviation] | 0.68 |
| Resolution [100μm Slit ; typical , Actually Permitted 20% Deviation] | 0.37 |
| Resolution [100μm Slit ; typical , Actually Permitted 20% Deviation] | 0.36 |
| Resolution [100μm Slit ; typical , Actually Permitted 20% Deviation] | 0.53 |
| Resolution [100μm Slit ; typical , Actually Permitted 20% Deviation] | 0.70 |
| Resolution [100μm Slit ; typical , Actually Permitted 20% Deviation] | 1.08 |
| Resolution [100μm Slit ; typical , Actually Permitted 20% Deviation] | 1.44 |
| Resolution [200μm Slit ; typical , Actually Permitted 20% Deviation] | 0.75 |
| Resolution [200μm Slit ; typical , Actually Permitted 20% Deviation] | 0.74 |
| Resolution [200μm Slit ; typical , Actually Permitted 20% Deviation] | 1.11 |
| Resolution [200μm Slit ; typical , Actually Permitted 20% Deviation] | 1.45 |
| Resolution [200μm Slit ; typical , Actually Permitted 20% Deviation] | 1.44 |
| Resolution [200μm Slit ; typical , Actually Permitted 20% Deviation] | 2.25 |
| Resolution [200μm Slit ; typical , Actually Permitted 20% Deviation] | 2.98 |
| Spectral Performance - Detection Range | 200~1100nm,详见《Model表 |
| Spectral Performance - Wavelength Resolution | As fine as 0.02nm, based on a 3600-line grating; see Technical Parameters |
| Spectral Performance - Optical Resolution | As fine as 0.06nm (FWHM), based on a 3600-line grating and a 10μm slit; see Technical Parameters |
| Spectral Performance - Detector | Hamamatsu, 2048/4096pixels CMOS |
| Spectral Performance - Higher-Order Diffraction Elimination | 7 front-mounted and 4 rear-mounted filter options to eliminate spectral ghost lines |
| Spectral Performance - Optical Bench | Focal length 72.5mm, f-number 7.5, symmetric C-T optical path |
| Spectral Performance - Integration Time | 9μs~60s |
| Spectral Performance - Dynamic Range | 4500:1 |
| Spectral Performance - Signal-to-Noise Ratio | 335:1 |
| Spectral Performance - Stray Light | 0.05%-1%, depending on the grating |
| Spectral Performance - Corrected Linearity | 99% |
| External Interfaces - Fiber Interface | SMA905 |
| External Interfaces - Data Transmission | USB, Ethernet |
| External Interfaces - Expansion Function Port | D-Sub 15Pin interface, supports trigger input / output, GPIO, and other functions |
| External Interfaces - External Trigger | 9 trigger modes |
| External Interface-Trigger Interface | SMB |
| External Interfaces - Trigger Delay | 380ns~60s adjustable, 20ns step |
| External Interface-I/O Port | 4 programmable I/O ports, 1 analog output, 1 power output (5V/100mA) |
| Other - Dimensions | 147 mm³ × 111 mm³ × 45 mm³ |
| Other - Weight | 700g |
| Other - A/D Bit Depth | 16-bit |
| Other - Power Supply | 12~24VDC,3W |
Applications
Coal: research into coal quality, combustion diagnostics, and pyrolysis requires a fast-response spectrometer with excellent temperature stability and real-time inline monitoring. Metallurgy: measuring C, Si, Mn, and other elements in steel to identify impurities requires avoiding pulsed-laser and continuous radiation while detecting trace-element atomic lines. Medicine: blood testing, biological tissue analysis, and elemental imaging require very high spectral resolution to distinguish characteristic peaks of different elements accurately.
Key Features
High-resolution optics: AESview™ places a CMOS detector on a 72.5mm focal-length platform for spectral peak identification at resolution as fine as 0.06nm. Nanosecond timing: SuperEngine™ provides minimum integration time 9μs, trigger delay below 1μs, and ns trigger jitter, reducing unwanted early-plasma continuous-spectrum acquisition to improve signal-to-noise ratio and repeatability. Stable Ethernet: Gigabit Ethernet supports real-time industrial connectivity, with buffered acquisition up to 2000 frames/second. Temperature stability: HeatResist™ supports 20~40℃ operation and wavelength drift down to 0.05pixel/℃ for inline integration.
Datasheet
Please provide your email to download the datasheet.
Your name
Email Address
Invalid email format. Please try again.
Send Request
Supplier Information
Shanghai Ideaoptics Co., Ltd. is a national-level specialized and sophisticated 'Little Giant' enterprise, a deep-spectrum technology innovator. Devoted to the micro-nano optoelectronic field, it develops intelligent full-spectrum technology integrating photonics and AI, building an internationally leading deep-spectrum platform. The company provides comprehensive solutions from technology to products, including micro spectrometers, angle-resolved spectrometers, and confocal Raman spectrometers, widely applied in IC chips, optical chips, biochips, AR/VR, and advanced displays. Through joint R&D centers with universities, Ideaoptics continuously launches breakthrough products, serving over 3,000 customers and cooperating with 170+ semiconductor, advanced materials, and biomedical enterprises, aiming to advance photonic integration and empower semiconductor manufacturing.
Contact Us
Loading...
GetExperimental Plan
Name
Phone
+86
Organization
Use Case

Global Photonics Products
Database Platform
Database Platform
With 16 years of experience, we provide high-quality products and services to universities, research institutes, and industry.
50+ Detailed Categories · 3,000+ Global Brands · 100,000+ Photonics Products
1 Million+
In-depth analysis of professional academic resources in photonics
300,000
ProductsDatasheets Available Free
We will keep your personal information strictly confidential.
Product Quote
+86
* Select the quoting party:
By submitting, you agree to the User Service Agreement and Privacy Policy