CarrierFiz Transient Interferometers CarrierFiz 100
CarrierFiz transient measurement provides accurate, reliable optics under severe vibration/airflow where conventional mechanical phase shifting fails. CarrierFiz tilts the test path by a specified amount and calibrates system error with patented CarrierFiz technology. High optical transfer and a powerful stabilized laser let a fast camera capture a fringe image instantaneously, analyzed by Sirius carrier-fringe methods. Under airflow, CarrierFiz captures many images over time and averages phase to eliminate disturbance effects. CarrierFiz also includes mechanical phase shifting for transient carrier, PSI and FPSI modes. Unlike carrier mode, FPSI needs no special cavity tilt or system-error calibration for precise VC-B-environment measurement. Dynamic cases: large optics/long cavities may prevent placing instrument and sample on one isolation table; CarrierFiz mounts on a workbench with five-axis adjustment for testing. Single-point diamond turning requires repeated time-consuming positioning/repositioning after figure tests. CarrierFiz inline transient measurement improves accuracy and saves repeated removal/remounting. Enclosing CarrierFiz in a sealed cover prevents workshop oil-vapor effects.
Overview
Specifications
| Parameter | Value |
|---|---|
| Measurement Method | Fizeau Interferometry Principle |
| Effective Clear Aperture | 101.6mm(4 inches ) |
| Light Source | Stabilized He-Ne Laser (632.8nm), Coherence Length >300m |
| Camera | Sensor Format 2/3″, Effective Imaging Resolution 2Kx2K |
| Lateral Resolution [Full aperture; mechanical phase-shifting mode] | Full-aperture resolved fringe count >450 pairs (mechanical phase-shifting mode) |
| Software Algorithms | Sirius Transient Carrier and Vibration-Resistant Phase Shifting |
| RMS Simple Repeatability [2δ; Mechanical Phase-Shifting Mode] | <λ/10000 (mechanical phase-shifting mode) |
| RMS Wavefront Repeatability [mean+2δ; Mechanical Phase-Shifting Mode] | <0.35nm (mechanical phase-shifting mode) |
| Zoom [Fixed Magnification] | 1×, fixed magnification |
| Measurement Mode | Three Modes: Transient Carrier, PSI and FPSI |
| Alignment Method | Two-Point Crosshair Alignment, Alignment Angle ±3° |
| Pupil Focus Adjustment Range | ±2.5m |
| Optical Center Height | 220mm |
| Power Supply | 100-240VAC,50/60Hz |
| Dimensions [Length, width, and height] | 704 mm × 330 mm × 460 mm |
| Weight | 40KG |
| Operating Ambient Temperature | 15℃-30℃ |
| Rate of Temperature Change | <1.0℃/30min |
| Humidity | No Greater Than 70% |
| Quality Standard | GJB/J 6221-2008 |
Applications
Key Features
Datasheet
Supplier Information
Loading...
Name
Phone
Organization
Use Case

Database Platform