BCSP-IT Series Small-Aperture Transmittance Spectral Analyzer

BCSP-IT Series Small-Aperture Transmittance Spectral Analyzer

Supplier
Bcoptical
Category
Optical Spectrum Analyzers
Origin
China

The BCSP-I/T small-aperture transmittance spectral analyzer is designed specifically to measure the transmittance of small-aperture optical elements and lenses. It provides fast, accurate measurements and displays real-time transmittance at one or multiple wavelengths, average transmittance over a specified band, and maximum and minimum values.

Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

The BCSP-I/T small-aperture transmittance spectral analyzer is designed specifically to measure the transmittance of small-aperture optical elements and lenses. It provides fast, accurate measurements and displays real-time transmittance at one or multiple wavelengths, average transmittance over a specified band, and maximum and minimum values.

Specifications

ParameterValue
BCSP-I/T - Detection Range380-1050 nm
BCSP-I/T - Signal-to-Noise Ratio250:1
BCSP-I/T - Wavelength Resolution0.2-1nm
BCSP-I/T - Relative Detection Error<0.5%(400-800nm)
BCSP-I/T - Measurement MethodTransmittance Referenced to Air
BCSP-I/T - Repeatability±0.3% 380nm-450nm;±0.1% 460nm-800nm;±0.3% 810nm-1050nm
BCSP-I/T - Single Measurement Time<50ms
BCSP-I/T - Wavelength Accuracy<1nm
BCSP-I/T - Spot Size≥0.3mm
BCSP-I/T - OtherReport Printing and Automatic Judgment; Suitable for Batch Inspection
BCSP-I/T - Lens Specification RequirementsEffective Diameter ≥0.4mm, Lens Outside Diameter ≥4mm
BCSP-I/T - Lens Assembly Specification RequirementsPupil Diameter ≥0.3mm, Output Spot Diameter ≤3mm (Integrating Sphere Receiving End); Total Lens Length ≤30mm
BCSP-I/T - Equipment Dimensions265(W)×480(D)×348(H)mm
BCSP-I/T - Equipment Weight18.5 kg
BCSP-I/T - Operating EnvironmentLevel, Vibration-Free Location; Temperature:+15℃ to+30℃; Humidity:60% or Below, Noncondensing
BCSP-I/T - Operating Voltage / Power150W; 220V
BCSP-I/T - Warranty Period1 yr
BCSP-I/TI - Detection Range380-1100 nm
BCSP-I/TI - Signal-to-Noise Ratio450:1
BCSP-I/TI - Wavelength Resolution0.2-1nm
BCSP-I/TI - Relative Detection Error<0.2%(400-800nm)
BCSP-I/TI - Measurement MethodTransmittance Referenced to Air
BCSP-I/TI - Repeatability±0.2% 380nm-450nm;±0.05% 460nm-800nm;±0.2% 810nm-1100nm
BCSP-I/TI - Single Measurement Time<50ms
BCSP-I/TI - Wavelength Accuracy<1nm
BCSP-I/TI - Spot Size≥0.3mm
BCSP-I/TI - OtherReport Printing and Automatic Judgment; Suitable for Batch Inspection
BCSP-I/TI - Lens Specification RequirementsEffective Diameter ≥0.4mm, Lens Outside Diameter ≥4mm
BCSP-I/TI - Lens Assembly Specification RequirementsPupil Diameter ≥0.3mm, Output Spot Diameter ≤3mm (Integrating Sphere Receiving End); Total Lens Length ≤30mm
BCSP-I/TI - Equipment Dimensions265(W)×480(D)×348(H)mm
BCSP-I/TI - Equipment Weight18.5 kg
BCSP-I/TI - Operating EnvironmentLevel, Vibration-Free Location; Temperature:+15℃ to+30℃; Humidity:60% or Below, Noncondensing
BCSP-I/TI - Operating Voltage / Power150W; 220V
BCSP-I/TI - Warranty Period1 yr

Key Features

1. Small measurement aperture: suitable for optical products with spots ≤0.3mm. 2. Fast measurement: a single measurement takes less than 1s, and the sample position can be adjusted on the platform. 3. Low background-light interference: no darkroom is required, and ambient light has little effect. 4. Flexible, cost-saving configuration: the equipment can be used independently or as an auxiliary transmission-measurement structure for a BCSP-I/II/PRO host, providing a cost-effective solution that reduces purchase costs.

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Bc
Bcoptical
View Supplier →
Guangdong Beichuang Optoelectronics Technology Co., Ltd. was established in 2009, headquartered in Chancheng District, Foshan City, Guangdong Province. After years of development and accumulation, the company now has overall supporting capabilities in R&D, manufacturing, and sales, mainly engaged in optical testing instruments, optical lenses, optical lenses, automation equipment, and technical services. The headquarters plays a key role as the center for R&D, planning, marketing, and capital operations. Its wholly-owned subsidiaries Beichuang Optoelectronics Technology (Shaoyang) Co., Ltd., Foshan Lianyi Optical Co., Ltd., and the lens factory are the company's main manufacturing bases, with steadily improving manufacturing capabilities. Its holding subsidiary Foshan Quying Technology Co., Ltd. focuses on the R&D and production of projector lenses, independently developing more than 50 types of projector lenses and more than 100 types of security lenses. With high-quality service levels, it serves related enterprises at home and abroad, providing strong support for the company's development. With the continuous improvement of corporate governance structure and standardization, the company has attracted many investment institutions, professional technical talents, and management talents to join. Development is the theme we are facing directly. The pace of innovation has never stopped. The company has independently developed and designed multiple optical lenses, spectral analysis instruments, and non-contact thickness measuring instruments, which have been widely used in many optical production enterprises and scientific research units at home and abroad and are well received. As a national high-tech enterprise, all our products are independently developed and produced, and we own independent intellectual property rights. Talent is the key to success. Building a stronger team is the focus of our current work. We are willing to strive for self-improvement and provide better products and services to our customers.

Request a Quote

Our team responds within 24–48 hours
BCSP-IT Series Small-Aperture Transmittance Spectral Analyzer
Bcoptical · Optical Spectrum Analyzers
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →