1×N(2×N) Single Mode Coupler Module
1×N (2×N) coupler splitter modules are cascaded with the single mode couplers. These modules are widely used for FTTH, LAN, and CATV optical networks.
Specification Snapshot
Insertion loss [SSSC/SWBC;N×4;N=1,2; Without connector;Grade P]
≤6.9 dB
Insertion loss [SSSC/SWBC;N×4;N=1,2; Without connector;Grade A]
≤7.3 dB
Insertion loss [SSSC/SWBC;N×6;N=1,2; Without connector;Grade P]
≤9.0 dB
Insertion loss [SSSC/SWBC;N×6;N=1,2; Without connector;Grade A]
≤9.6 dB
Insertion loss [SSSC/SWBC;N×8;N=1,2; Without connector;Grade P]
≤10.4 dB
Insertion loss [SSSC/SWBC;N×8;N=1,2; Without connector;Grade A]
≤11.0 dB
Request a Quote
Download Datasheet
Overview
1×N (2×N) coupler splitter modules are cascaded with the single mode couplers. These modules are widely used for FTTH, LAN, and CATV optical networks.
Specifications
| Parameter | Value |
|---|---|
| Insertion loss [SSSC/SWBC;N×4;N=1,2; Without connector;Grade P] | ≤6.9 dB |
| Insertion loss [SSSC/SWBC;N×4;N=1,2; Without connector;Grade A] | ≤7.3 dB |
| Typical excess loss [SSSC/SWBC;N×4;N=1,2; Without connector;Grade P/A Shared] | 0.25 dB |
| PDL [SSSC/SWBC;N×4;N=1,2; Without connector;Grade P/A Shared] | ≤0.25 dB |
| Insertion loss [SSSC/SWBC;N×6;N=1,2; Without connector;Grade P] | ≤9.0 dB |
| Insertion loss [SSSC/SWBC;N×6;N=1,2; Without connector;Grade A] | ≤9.6 dB |
| Typical excess loss [SSSC/SWBC;N×6;N=1,2; Without connector;Grade P/A Shared] | 0.3 dB |
| PDL [SSSC/SWBC;N×6;N=1,2; Without connector;Grade P/A Shared] | ≤0.35 dB |
| Insertion loss [SSSC/SWBC;N×8;N=1,2; Without connector;Grade P] | ≤10.4 dB |
| Insertion loss [SSSC/SWBC;N×8;N=1,2; Without connector;Grade A] | ≤11.0 dB |
| Typical excess loss [SSSC/SWBC;N×8;N=1,2; Without connector;Grade P/A Shared] | 0.4 dB |
| PDL [SSSC/SWBC;N×8;N=1,2; Without connector;Grade P/A Shared] | ≤0.35 dB |
| Insertion loss [SSSC/SWBC;N×12;N=1,2; Without connector;Grade P] | ≤12.4 dB |
| Insertion loss [SSSC/SWBC;N×12;N=1,2; Without connector;Grade A] | ≤13.2 dB |
| Typical excess loss [SSSC/SWBC;N×12;N=1,2; Without connector;Grade P/A Shared] | 0.5 dB |
| PDL [SSSC/SWBC;N×12;N=1,2; Without connector;Grade P/A Shared] | ≤0.45 dB |
| Insertion loss [SSSC/SWBC;N×16;N=1,2; Without connector;Grade P] | ≤13.8 dB |
| Insertion loss [SSSC/SWBC;N×16;N=1,2; Without connector;Grade A] | ≤14.6 dB |
| Typical excess loss [SSSC/SWBC;N×16;N=1,2; Without connector;Grade P/A Shared] | 0.55 dB |
| PDL [SSSC/SWBC;N×16;N=1,2; Without connector;Grade P/A Shared] | ≤0.45 dB |
| Insertion loss [SSSC/SWBC;N×24;N=1,2; Without connector;Grade P] | ≤15.8 dB |
| Insertion loss [SSSC/SWBC;N×24;N=1,2; Without connector;Grade A] | ≤16.8 dB |
| Typical excess loss [SSSC/SWBC;N×24;N=1,2; Without connector;Grade P/A Shared] | 0.6 dB |
| PDL [SSSC/SWBC;N×24;N=1,2; Without connector;Grade P/A Shared] | ≤0.55 dB |
| Insertion loss [SSSC/SWBC;N×32;N=1,2; Without connector;Grade P] | ≤17.4 dB |
| Insertion loss [SSSC/SWBC;N×32;N=1,2; Without connector;Grade A] | ≤18.4 dB |
| Typical excess loss [SSSC/SWBC;N×32;N=1,2; Without connector;Grade P/A Shared] | 0.7 dB |
| PDL [SSSC/SWBC;N×32;N=1,2; Without connector;Grade P/A Shared] | ≤0.55 dB |
| Insertion loss [SSSC/SWBC;N×64;N=1,2; Without connector;Grade P] | ≤20.9 dB |
| Insertion loss [SSSC/SWBC;N×64;N=1,2; Without connector;Grade A] | ≤22.1 dB |
| Typical excess loss [SSSC/SWBC;N×64;N=1,2; Without connector;Grade P/A Shared] | 0.85 dB |
| PDL [SSSC/SWBC;N×64;N=1,2; Without connector;Grade P/A Shared] | ≤0.65 dB |
| Insertion loss [SDWC/STWC;N×4;N=1,2; Without connector;Grade P] | ≤7.2 dB |
| Insertion loss [SDWC/STWC;N×4;N=1,2; Without connector;Grade A] | ≤7.6 dB |
| Typical excess loss [SDWC/STWC;N×4;N=1,2; Without connector;Grade P/A Shared] | 0.3 dB |
| PDL [SDWC/STWC;N×4;N=1,2; Without connector;Grade P/A Shared] | ≤0.3 dB |
| Insertion loss [SDWC/STWC;N×6;N=1,2; Without connector;Grade P] | ≤9.6 dB |
| Insertion loss [SDWC/STWC;N×6;N=1,2; Without connector;Grade A] | ≤10.2 dB |
| Typical excess loss [SDWC/STWC;N×6;N=1,2; Without connector;Grade P/A Shared] | 0.4 dB |
| PDL [SDWC/STWC;N×6;N=1,2; Without connector;Grade P/A Shared] | ≤0.4 dB |
| Insertion loss [SDWC/STWC;N×8;N=1,2; Without connector;Grade P] | ≤10.8 dB |
| Insertion loss [SDWC/STWC;N×8;N=1,2; Without connector;Grade A] | ≤11.4 dB |
| Typical excess loss [SDWC/STWC;N×8;N=1,2; Without connector;Grade P/A Shared] | 0.45 dB |
| PDL [SDWC/STWC;N×8;N=1,2; Without connector;Grade P/A Shared] | ≤0.4 dB |
| Insertion loss [SDWC/STWC;N×12;N=1,2; Without connector;Grade P] | ≤13.2 dB |
| Insertion loss [SDWC/STWC;N×12;N=1,2; Without connector;Grade A] | ≤14.0 dB |
| Typical excess loss [SDWC/STWC;N×12;N=1,2; Without connector;Grade P/A Shared] | 0.55 dB |
| PDL [SDWC/STWC;N×12;N=1,2; Without connector;Grade P/A Shared] | ≤0.5 dB |
| Insertion loss [SDWC/STWC;N×16;N=1,2; Without connector;Grade P] | ≤14.4 dB |
| Insertion loss [SDWC/STWC;N×16;N=1,2; Without connector;Grade A] | ≤15.2 dB |
| Typical excess loss [SDWC/STWC;N×16;N=1,2; Without connector;Grade P/A Shared] | 0.6 dB |
| PDL [SDWC/STWC;N×16;N=1,2; Without connector;Grade P/A Shared] | ≤0.5 dB |
| Insertion loss [SDWC/STWC;N×24;N=1,2; Without connector;Grade P] | ≤16.8 dB |
| Insertion loss [SDWC/STWC;N×24;N=1,2; Without connector;Grade A] | ≤17.8 dB |
| Typical excess loss [SDWC/STWC;N×24;N=1,2; Without connector;Grade P/A Shared] | 0.7 dB |
| PDL [SDWC/STWC;N×24;N=1,2; Without connector;Grade P/A Shared] | ≤0.6 dB |
| Insertion loss [SDWC/STWC;N×32;N=1,2; Without connector;Grade P] | ≤18.0 dB |
| Insertion loss [SDWC/STWC;N×32;N=1,2; Without connector;Grade A] | ≤19.0 dB |
| Typical excess loss [SDWC/STWC;N×32;N=1,2; Without connector;Grade P/A Shared] | 0.75 dB |
| PDL [SDWC/STWC;N×32;N=1,2; Without connector;Grade P/A Shared] | ≤0.6 dB |
| Insertion loss [SDWC/STWC;N×64;N=1,2; Without connector;Grade P] | ≤21.6 dB |
| Insertion loss [SDWC/STWC;N×64;N=1,2; Without connector;Grade A] | ≤22.8 dB |
| Typical excess loss [SDWC/STWC;N×64;N=1,2; Without connector;Grade P/A Shared] | 0.9 dB |
| PDL [SDWC/STWC;N×64;N=1,2; Without connector;Grade P/A Shared] | ≤0.7 dB |
| Operating wavelength [SSSC/SWBC; others on request] | 1310 or1550 |
| Operating bandwidth [SSSC] | ±15 nm |
| Operating bandwidth [SWBC] | ±40 nm |
| Operating wavelength [SDWC] | 1310 and1550 |
| Operating bandwidth [SDWC] | ±40 nm |
| Operating wavelength [STWC] | 1310,1490 and1550 |
| Operating bandwidth [STWC] | 1310±40,1490±10 and1550±40 |
| Operating temperature [SSSC/SWBC/SDWC/STWC; Without connector] | -40 ~ +85 ℃ |
| Fiber lead length [others on request; SSSC/SWBC/SDWC/STWC] | 1 meter |
| Fiber type [SSSC/SWBC/SDWC/STWC] | 900μm,2mm,3mm loose tube |
| ABS Box Dimensions(L×W×H) [N×4;N=1,2;SSSC/SWBC/SDWC/STWC] | 100 mm × 80 mm × 10 mm |
| ABS Box Dimensions(L×W×H) [N×6;N=1,2;SSSC/SWBC/SDWC/STWC] | 100 mm × 80 mm × 10 mm |
| ABS Box Dimensions(L×W×H) [N×8;N=1,2;SSSC/SWBC/SDWC/STWC] | 100 mm × 80 mm × 10 mm |
| ABS Box Dimensions(L×W×H) [N×12;N=1,2;SSSC/SWBC/SDWC/STWC] | 125 mm × 96 mm × 16 mm |
| ABS Box Dimensions(L×W×H) [N×16;N=1,2;SSSC/SWBC/SDWC/STWC] | 125 mm × 96 mm × 16 mm |
| ABS Box Dimensions(L×W×H) [N×24;N=1,2;SSSC/SWBC/SDWC/STWC] | 141 mm × 115 mm × 18 mm |
| ABS Box Dimensions(L×W×H) [N×32;N=1,2;SSSC/SWBC/SDWC/STWC] | 141 mm × 115 mm × 18 mm |
| ABS Box Dimensions(L×W×H) [N×64;N=1,2;SSSC/SWBC/SDWC/STWC] | On request |
| Package Dimensions [19 Inch Rack;1U] | 482.6 mm × 278 mm × 44 mm |
| Installation Dimensions [19 Inch Rack;1U] | 462.7×11.0(4-Φ6) |
| Package Dimensions [19 Inch Rack;2U] | 482.6 mm × 278 mm × 88 mm |
| Installation Dimensions [19 Inch Rack;2U] | 462.7×27.5(6-Φ6) |
| Package Dimensions [19 Inch Rack;3U] | 482.6 mm × 278 mm × 132 mm |
| Installation Dimensions [19 Inch Rack;3U] | 462.7×49.5(6-Φ6) |
| Package Dimensions [LGX Box;1U] | 130 mm × 127 mm × 29 mm |
| Installation Dimensions [LGX Box;1U] | 118(2-Φ6) |
| Package Dimensions [LGX Box;2U] | 130 mm × 127 mm × 58 mm |
| Installation Dimensions [LGX Box;2U] | 118×29.2(2-Φ6) |
Applications
FTTH, LAN, and CATV optical networks
Datasheet
Product Datasheet
PDF
Supplier Information
Shenzhen LightComm Technology Co., Ltd., founded in 2001 by Dr. Yue Chaoyu, an optical fiber expert from Tsinghua University, is engaged in the R&D, production and sales of optoelectronic devices and equipment. It maintains leading advantages in key technologies of optical devices, with world-leading capacity in optical couplers and high-power fiber combiners, having replaced imports. Products and R&D cover fiber transmission fields, and the company is recognized as a national high-tech enterprise and a specialized 'Little Giant' enterprise. It has relocated to a high-tech park with over 8000 m² area. The company holds numerous patents and has participated in major national projects.
Contact Us
Loading...
GetExperimental Plan
Name
Phone
+86
Organization
Use Case

Global Photonics Products
Database Platform
Database Platform
With 16 years of experience, we provide high-quality products and services to universities, research institutes, and industry.
50+ Detailed Categories · 3,000+ Global Brands · 100,000+ Photonics Products
1 Million+
In-depth analysis of professional academic resources in photonics
300,000
ProductsDatasheets Available Free
We will keep your personal information strictly confidential.
Product Quote
+86
* Select the quoting party:
By submitting, you agree to the User Service Agreement and Privacy Policy