UV Absorbance Measurement System VIS3-180-500

UV Absorbance Measurement System VIS3-180-500

Supplier
Jnewtech
Part Number
VIS3-180-500
Category
Optical Spectrum Analyzers
Origin
China

Shanghai Jiepu Technology's high-sensitivity UV absorption instrument detects water or flue-gas pollutants. An imported flashing xenon lamp provides stable output for over 5 years of continuous use. Concentration measurement: 1. Turn off the source and collect electronic noise. 2. Turn on, set 100ms exposure and collect the reference. 3. Place the sample and collect its spectrum; X is wavelength and Y transmittance. 4. Absorbance = Log10(T). Beer–Lambert formula: A=-log10(T transmittance)=Kbc. A is absorbance; T is output intensity I divided by incident intensity I0. K is molar absorptivity, depending on substance and wavelength λ. c is concentration in mol/L; b is absorbing-layer thickness, with the unit unspecified. L can replace b with the same meaning. Example: UV absorption under the national standard quantifies oil in water. The figure shows a fully linear concentration response at 260nm.

Specification Snapshot
Wavelength Accuracy
<0.5nm
Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

Shanghai Jiepu Technology's high-sensitivity UV absorption instrument detects water or flue-gas pollutants. An imported flashing xenon lamp provides stable output for over 5 years of continuous use. Concentration measurement: 1. Turn off the source and collect electronic noise. 2. Turn on, set 100ms exposure and collect the reference. 3. Place the sample and collect its spectrum; X is wavelength and Y transmittance. 4. Absorbance = Log10(T). Beer–Lambert formula: A=-log10(T transmittance)=Kbc. A is absorbance; T is output intensity I divided by incident intensity I0. K is molar absorptivity, depending on substance and wavelength λ. c is concentration in mol/L; b is absorbing-layer thickness, with the unit unspecified. L can replace b with the same meaning. Example: UV absorption under the national standard quantifies oil in water. The figure shows a fully linear concentration response at 260nm.

Specifications

ParameterValue
Wavelength Range180-500nm (Also Available 200-800nm)
Applicable ApplicationsApplications Toward the UV Region
Recommended Light SourceFlashing Xenon Lamp
Wavelength Resolution2048 channels, 0.3nm spacing (minimum)
DetectorCMOS linear array, 2048 pixels, linearity >99.8%
Operating ModeSingle acquisition/continuous acquisition/external triggering
Exposure Time0.06 ms-65m
Optical slit25um ( Default ) / 50um / 100um, 200um
Absorbance0-3 AU
Slope MeasurementQuantitative Concentration Measurement Based on the Beer-Lambert Law
PLS QuantificationBuilt-In PLS Software Learning Function for Quantitative Analysis
Spot size1-3mm adjustable
Measurement RangeTransmittance 0-100%
Single Acquisition Time0.01 s
Wavelength Accuracy<0.5nm
Wavelength Repeatability0.1nm
Transmittance Accuracy0.5%
Instrument Repeatability>99.9%
Dynamic range2000:1
CircuitBuilt-in xenon lamp control circuit
Connectors and Data30PIN connector, including USB (480Mbps)/TTL (3.3v)/RS232/485
Integration SchemeTransmittance, Absorptance
Self-Recovery Device7x24-hour, 365-day continuous operation; built-in watchdog
Dimensions300 mm × 185 mm × 104 mm

Key Features

1. Advanced spectroscopy provides rapid UV transmission and absorbance measurement. 2. A highly stable flashing xenon source covers 200-2500nm; an imported Japanese Hamamatsu detector provides high precision, low noise and 2048 channels. 3. DDOS ultraviolet differential measurement detects pollutants in water and flue gas. 4. Professional software sets, stores and prints data lists to operational needs. 5. Integrated analysis/management supports customer-specific methods meeting domestic/international standards. High resolution reaches 0.2nm, depending on wavelength range; high UV/VIS sensitivity; USB, RS232, TTL, 485 and modbus; SNR 800:1, snr=(Signal-Noise)/Devication; dynamic range 2000:1, DR=(saturation/Dark); ultralow stray light; external-trigger, auto-exposure and software-exposure modes; integration 8ms-65s; built-in xenon control and SDK. Transmission measurement system. SpectrumFactory professional processing software: 1. Transmission/reflection measurement of glass or transparent objects; 2. Raman spectra with a laser; 3. UV absorbance with a xenon lamp and liquid concentration from Beer-Lambert law; 4. Automatic one-, two- or three-axis stage and microscope-motor control, autofocus, cameras, stitched spectra, circular-arc acquisition and S-curve acceleration/deceleration; 5. X-axis time-series stability testing with a mercury-argon lamp; 6. Y-axis time-series testing of laser center-wavelength stability; 7. Motorized microscopy for transmission/reflection and Raman hyperspectral imaging; 8. LIBS metal-composition measurement with a 1064 Nd-YAG laser; 9. Film thickness 5um-100um; 10. Colorimetry including XYZ, Lab, Yxy, HSV, LCH and RGB; 11. Remote online spectral measurements; 12. Uniformity testing, including pharmaceutical granules and LED illumination. Exceptional stability: Industrial-system stability combines spectrometer and source stability. Spectrometer intensity stability >99.99%; wavelength accuracy +/-0.5nm; wavelength temperature stability; wavelength repeatability. Halogen-lamp stability >99.9%; after 15-minute warm-up, lamp stability >99.9% and complete-system stability >99%, measured over 8 hours. UV absorption OEM module: Includes a fiber spectrometer and flashing xenon lamp. The spectrometer integrates xenon control, requiring no external module, and an internal calculation module directly outputs ABS absorbance without host-computer calculation.

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Jn
Jnewtech
View Supplier →
Shanghai Jiepu Technology Co., Ltd. is a high-tech enterprise with over ten years of experience in spectroscopy. As a leading domestic supplier of spectroscopy R&D, production and integrated solutions, we are committed to the independent R&D and production of domestic spectrometers. Our product line includes micro fiber optic spectrometers, Raman spectrometers, various transmission/reflection optical systems, Raman optical systems, and micro-imaging optical systems. We provide one-stop optical solutions for various industries. Our applications cover environmental water quality and flue gas monitoring, drug testing, public security, jewelry identification, skin quality testing, crop testing, cancer cell testing, new materials testing, etc. With a senior engineering team and cooperation with universities like Fudan and Tongji, we deliver high-performance, cost-effective products and services.

Request a Quote

Our team responds within 24–48 hours
UV Absorbance Measurement System VIS3-180-500
Jnewtech · Optical Spectrum Analyzers
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →