Shanghai Jiepu Technology's high-sensitivity UV absorption instrument detects water or flue-gas pollutants. An imported flashing xenon lamp provides stable output for over 5 years of continuous use. Concentration measurement: 1. Turn off the source and collect electronic noise. 2. Turn on, set 100ms exposure and collect the reference. 3. Place the sample and collect its spectrum; X is wavelength and Y transmittance. 4. Absorbance = Log10(T). Beer–Lambert formula: A=-log10(T transmittance)=Kbc. A is absorbance; T is output intensity I divided by incident intensity I0. K is molar absorptivity, depending on substance and wavelength λ. c is concentration in mol/L; b is absorbing-layer thickness, with the unit unspecified. L can replace b with the same meaning. Example: UV absorption under the national standard quantifies oil in water. The figure shows a fully linear concentration response at 260nm.
| Parameter | Value |
| Wavelength Range | 180-500nm (Also Available 200-800nm) |
| Applicable Applications | Applications Toward the UV Region |
| Recommended Light Source | Flashing Xenon Lamp |
| Wavelength Resolution | 2048 channels, 0.3nm spacing (minimum) |
| Detector | CMOS linear array, 2048 pixels, linearity >99.8% |
| Operating Mode | Single acquisition/continuous acquisition/external triggering |
| Exposure Time | 0.06 ms-65m |
| Optical slit | 25um ( Default ) / 50um / 100um, 200um |
| Absorbance | 0-3 AU |
| Slope Measurement | Quantitative Concentration Measurement Based on the Beer-Lambert Law |
| PLS Quantification | Built-In PLS Software Learning Function for Quantitative Analysis |
| Spot size | 1-3mm adjustable |
| Measurement Range | Transmittance 0-100% |
| Single Acquisition Time | 0.01 s |
| Wavelength Accuracy | <0.5nm |
| Wavelength Repeatability | 0.1nm |
| Transmittance Accuracy | 0.5% |
| Instrument Repeatability | >99.9% |
| Dynamic range | 2000:1 |
| Circuit | Built-in xenon lamp control circuit |
| Connectors and Data | 30PIN connector, including USB (480Mbps)/TTL (3.3v)/RS232/485 |
| Integration Scheme | Transmittance, Absorptance |
| Self-Recovery Device | 7x24-hour, 365-day continuous operation; built-in watchdog |
| Dimensions | 300 mm × 185 mm × 104 mm |
1. Advanced spectroscopy provides rapid UV transmission and absorbance measurement. 2. A highly stable flashing xenon source covers 200-2500nm; an imported Japanese Hamamatsu detector provides high precision, low noise and 2048 channels. 3. DDOS ultraviolet differential measurement detects pollutants in water and flue gas. 4. Professional software sets, stores and prints data lists to operational needs. 5. Integrated analysis/management supports customer-specific methods meeting domestic/international standards. High resolution reaches 0.2nm, depending on wavelength range; high UV/VIS sensitivity; USB, RS232, TTL, 485 and modbus; SNR 800:1, snr=(Signal-Noise)/Devication; dynamic range 2000:1, DR=(saturation/Dark); ultralow stray light; external-trigger, auto-exposure and software-exposure modes; integration 8ms-65s; built-in xenon control and SDK. Transmission measurement system. SpectrumFactory professional processing software: 1. Transmission/reflection measurement of glass or transparent objects; 2. Raman spectra with a laser; 3. UV absorbance with a xenon lamp and liquid concentration from Beer-Lambert law; 4. Automatic one-, two- or three-axis stage and microscope-motor control, autofocus, cameras, stitched spectra, circular-arc acquisition and S-curve acceleration/deceleration; 5. X-axis time-series stability testing with a mercury-argon lamp; 6. Y-axis time-series testing of laser center-wavelength stability; 7. Motorized microscopy for transmission/reflection and Raman hyperspectral imaging; 8. LIBS metal-composition measurement with a 1064 Nd-YAG laser; 9. Film thickness 5um-100um; 10. Colorimetry including XYZ, Lab, Yxy, HSV, LCH and RGB; 11. Remote online spectral measurements; 12. Uniformity testing, including pharmaceutical granules and LED illumination. Exceptional stability: Industrial-system stability combines spectrometer and source stability. Spectrometer intensity stability >99.99%; wavelength accuracy +/-0.5nm; wavelength temperature stability; wavelength repeatability. Halogen-lamp stability >99.9%; after 15-minute warm-up, lamp stability >99.9% and complete-system stability >99%, measured over 8 hours. UV absorption OEM module: Includes a fiber spectrometer and flashing xenon lamp. The spectrometer integrates xenon control, requiring no external module, and an internal calculation module directly outputs ABS absorbance without host-computer calculation.
Please provide your email to download the datasheet.
Shanghai Jiepu Technology Co., Ltd. is a high-tech enterprise with over ten years of experience in spectroscopy. As a leading domestic supplier of spectroscopy R&D, production and integrated solutions, we are committed to the independent R&D and production of domestic spectrometers. Our product line includes micro fiber optic spectrometers, Raman spectrometers, various transmission/reflection optical systems, Raman optical systems, and micro-imaging optical systems. We provide one-stop optical solutions for various industries. Our applications cover environmental water quality and flue gas monitoring, drug testing, public security, jewelry identification, skin quality testing, crop testing, cancer cell testing, new materials testing, etc. With a senior engineering team and cooperation with universities like Fudan and Tongji, we deliver high-performance, cost-effective products and services.