Ocean Optics HR4000, HR2000, HR2000+ fiber optic spectrometer (HR2000CG-UV-NIR)
The broadband CG spectrometers use the HC-1 grating--a revolutionary grating with variable blaze wavelength, specially designed to provide a spectral output range of 200-1100 nm. Each CG series spectrometer has a 5 micron entrance slit, the patented HC-1. All CG series spectrometers use the HC-1 grating--a revolutionary composite grating, providing a spectral output range of 200-1100 nm. (See the HC-1 grating efficiency curve on the right). In addition to this composite grating, each CG series spectrometer has an OFLV high-order diffraction filter to eliminate the effects of second and third order diffraction. The grating and OFLV filter are installed and fixed in place during manufacture. The HR2000+CG is the only CG series spectrometer that allows full spectrum scans to be captured and stored into memory per second (when the spectrometer is connected to a PC via the USB2.0 port). The HR2000+CG is ideal for applications requiring fast response and high resolution monitoring. This innovative combination also created our fastest spectrometer - one scan per millisecond. The HR4000CG and HR2000+CG have a portable programmable microcontroller, providing flexible control of the spectrometer and accessories. By using a new 30PIT connector, you can execute many operating parameters in software, including controlling external light sources and retrieving data from external targets. There are 10 programmable data I/O interfaces to connect with other devices; one analog input and one analog output; a pulse generator to trigger devices. The HR2000CG does not include I/O, analog channels or a pulse generator
Overview
Specifications
| Parameter | Value |
|---|---|
| Dimensions | 148.6 mm × 104.8 mm × 45.1 mm |
| Weight | 570 g |
| Detector | Sony ILX511 linear silicon CCD array |
| Pixel | 2048 pixels |
| Pixel size | 14 μm × 200 μm |
| Pixel well depth | ~62,500 electrons |
| Sensitivity [400 nm] | 75 photons/count at 400 nm |
| Sensitivity [600 nm] | 41 photons/count at 600 nm |
| Design | f/4, Symmetrical crossed Czerny-Turner |
| focal length [input and output] | 101.6 mm input and output |
| entrance [wide slit] | 5 μm wide slit |
| Grating | HC-1, 300 lines per mm grating |
| detector collection lens | L2 |
| OFLV filter | OFLV-200-1100 |
| calibration and focusing lens | Standard |
| UV Upgrade Window | Yes, UV2 |
| Fiber optic connector | SMA 905 to 0.22 numerical aperture single-strand fiber |
| Wavelength Range | 200-1100 nm |
| Optical resolution (FWHM) | 1.0 nm FWHM |
| Signal-to-noise ratio [at full signal] | 250:1 (at full signal) |
| A/D resolution | 12 bit |
| dark noise | 3.2 RMS counts |
| Dynamic range | 2 x 10^8 (system); 1300:1 for a single acquisition |
| Integration time | 3 milliseconds to 65 seconds |
| Polarization [600 nm] | <0.05 % at 600 nm |
| Polarization [435 nm] | <0.10 % at 435 nm |
| Linearity correction | >99.8 % |
| Power consumption [5 VDC] | 90 mA @ 5 VDC |
| data transfer rate [USB 2.0 or USB 1.1] | Full scans into memory every 13 ms with USB 2.0 or USB 1.1 |
| Input/Output | No |
| Analog channel | No |
| Trigger modes | 3 modes |
| Filtering function | Yes |
| Connector | 20-pin connector |
| Operating System | Windows 98/Me/2000/XP, Mac OS X and Linux operating systems when using the USB port |
| computer interface [12 Mbps (USB1.1 compatible);RS-232 (2-wire) @ 115.2 K baud] | USB 2.0 @ 12 Mbps (USB1.1 compatible); RS-232 (2-wire) @ 115.2 K baud |
| Peripheral interface | SPI (3-wire); I2C inter-integrated circuit |