QE65000 Research-Grade Raman Spectrometer

QE65000 Research-Grade Raman Spectrometer

Supplier
Gzbiaoqi
Category
Spectrometers
Origin
China

QE65000 Research-Grade Raman Spectrometer; The QE65000 Research-Grade Spectrometer combines the functions of a detector, optical bench, and electronics to provide users with a sensitive system that meets applications under low-light conditions, such as fluorescence measurement, DNA sequencing, astronomy, and Raman spectroscopy. The QE65000 Research-Grade Spectrometer has a quantum efficiency of up to 90%, and features a very high signal-to-noise ratio and fast signal processing capability.; Quantum efficiency up to 90%; Higher system sensitivity; Excellent UV response capability; Meets the conditions for low-light-level applications; Onboard microcontroller; Plug-and-play USB; Optical bench; Installation and user manual; Specifications; The Ocean Optics QE65000 Research-Grade Raman Spectrometer is the most sensitive spectrometer among our developed products, and its quantum efficiency (defined as the efficiency of converting photons into photoelectrons) can reach 90%.; The QE65000 Research-Grade Raman Spectrometer contains a thin back-thinned (Back-thinned) detector with extremely strong UV sensitivity manufactured by Hamamatsu of Japan. Its two-dimensional pixel arrangement (1044 pixels horizontal × 64 pixels vertical) can respond to optical signals in the wavelength range of 200–1100 nm. The specific spectral range and resolution are determined by the user's choice of grating and entrance slit. The pixel columns of the detector are accumulated before data output, which minimizes the noise of the acquired data.; With the included thermoelectric cooler, the detector can be cooled to minus 20°C to reduce dark noise. The reduction of noise and dark signal allows the spectrometer's integration time to reach 15 minutes, and thus greatly improves the detection limit in low-light-level testing.; The spectrometer's low-noise detector and 16-bit analog-to-digital converter enable a dynamic range of 25000:1 and a signal-to-noise ratio greater than 1000:1.; Because the two-dimensional detector allows the spectrometer to make good use of the height of the entrance slit, the sensitivity of the Ocean Optics QE65000 Research-Grade Raman Spectrometer has been improved to a certain extent. In other spectrometers we produce, the light entering the optical bench is adjusted by the width of the entrance slit; the slit height has no effect because a linear detector cannot efficiently collect light across the entire height of the slit. By using the two-dimensional detector of the QE65000 Research-Grade Spectrometer, we can make better use of the additional optical signal from the height direction.; The thin back-thinned (Back-thinned) detector of the QE65000 Research-Grade Raman Spectrometer has excellent UV response capability and does not require an external coating to improve its performance.; The QE65000 Research-Grade Raman Spectrometer is an excellent choice for low-light applications, including fluorescence, Raman spectroscopy, DNA sequencing, astronomy, and thin-film reflection. As needed, users can set the spectrometer's integration time (similar to a camera's shutter speed) to a value within 8 ms–15 min without optical distortion. Below is an example of fluorescence analysis using the QE65000 Research-Grade Raman Spectrometer, the CUV-ALL four-way cuvette holder, and the PX-2 Xenon Light Source. Special note: In order to externally trigger the PX-2 Xenon Light Source, an HR4-BREAKOUT breakout box is also required.; Raman spectrum of an acetaminophen solid; this experiment used the QE65000 Research-Grade Spectrometer, a 785 nm laser, and a Raman probe.; User-Programmable Input/Output Ports; The module included with the QE65000 Research-Grade Raman Spectrometer contains 10 user-programmable digital input/output ports to facilitate connection with other devices; it also contains a pulse generator that can trigger other devices. During the spectrometer's integration period, users can use these input/output ports to turn on light sources, start or stop a process, or send messages and prompts. The operating parameters of the spectrometer can be controlled via software. In fact, the wavelength calibration coefficients specific to each spectrometer are also set in the spectrometer's memory chip.; Specifications of the QE65000 Research-Grade Raman Spectrometer; Physical Appearance of the Spectrometer; Dimensions; 182 mm x 110 mm x 47 mm; Weight; 1050 g; Spectrometer Detector; Detector Model; Hamamatsu S7031-1006; Detection Range; 200-1100 nm; Pixels; 1024 x 58 (total pixels 1044 x 64); Total size 24.6 square micrometers; Pixel Size; 24.576 square micrometers; Pixel Well Depth; 300000 electrons/pixel; 1500000 electrons/column; Sensitivity; 250 nm wavelength: 26 photons/count; other wavelengths: 22 electrons/count; Quantum Efficiency; 90% peak; Spectrometer Optical Bench; Design; f/4, crossed asymmetric Czerny-Turner optical path; Focal Length; 101.6 mm for both input and output; Entrance Aperture; slits of 5, 10, 25, 50, 100, or 200 μm width, or optical fiber (no slit); Optional Gratings; 14 optional gratings, UV to near-infrared; HC-1 Grating; Spectral Range 200–950 nm; Optional Detector Condenser Lens; None; Optional OFLV Filter; OFLV-QE Filter; Other Filters; Longpass OF-1 series filters; Calibration and Condenser Mirror; Standard; UV-Enhanced; Fiber Connection; SMA905 connector, connected to 0.22 aperture single-strand optical fiber; Optical Characteristics of the Spectrometer; Wavelength; Determined by grating; Fiber Resolution; 0.14–7.7 nm full width at half maximum (FWHM); Signal-to-Noise Ratio; 1000:1 (at full signal); A/D Conversion Resolution; 16-bit; Dark Noise; 3 RMS counts; Dynamic Range; 7.5 x 10^9 (system), 25000:1 (single operation); Integration Time; 8 ms–15 min; Optical Drift; Less than 0.08% at 600 nm; 0.4% at 435 nm; Corrected Linearity; >99.8%; Electronic Characteristics; Power Consumption; 5

Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

QE65000 Research-Grade Raman Spectrometer; The QE65000 Research-Grade Spectrometer combines the functions of a detector, optical bench, and electronics to provide users with a sensitive system that meets applications under low-light conditions, such as fluorescence measurement, DNA sequencing, astronomy, and Raman spectroscopy. The QE65000 Research-Grade Spectrometer has a quantum efficiency of up to 90%, and features a very high signal-to-noise ratio and fast signal processing capability.; Quantum efficiency up to 90%; Higher system sensitivity; Excellent UV response capability; Meets the conditions for low-light-level applications; Onboard microcontroller; Plug-and-play USB; Optical bench; Installation and user manual; Specifications; The Ocean Optics QE65000 Research-Grade Raman Spectrometer is the most sensitive spectrometer among our developed products, and its quantum efficiency (defined as the efficiency of converting photons into photoelectrons) can reach 90%.; The QE65000 Research-Grade Raman Spectrometer contains a thin back-thinned (Back-thinned) detector with extremely strong UV sensitivity manufactured by Hamamatsu of Japan. Its two-dimensional pixel arrangement (1044 pixels horizontal × 64 pixels vertical) can respond to optical signals in the wavelength range of 200–1100 nm. The specific spectral range and resolution are determined by the user's choice of grating and entrance slit. The pixel columns of the detector are accumulated before data output, which minimizes the noise of the acquired data.; With the included thermoelectric cooler, the detector can be cooled to minus 20°C to reduce dark noise. The reduction of noise and dark signal allows the spectrometer's integration time to reach 15 minutes, and thus greatly improves the detection limit in low-light-level testing.; The spectrometer's low-noise detector and 16-bit analog-to-digital converter enable a dynamic range of 25000:1 and a signal-to-noise ratio greater than 1000:1.; Because the two-dimensional detector allows the spectrometer to make good use of the height of the entrance slit, the sensitivity of the Ocean Optics QE65000 Research-Grade Raman Spectrometer has been improved to a certain extent. In other spectrometers we produce, the light entering the optical bench is adjusted by the width of the entrance slit; the slit height has no effect because a linear detector cannot efficiently collect light across the entire height of the slit. By using the two-dimensional detector of the QE65000 Research-Grade Spectrometer, we can make better use of the additional optical signal from the height direction.; The thin back-thinned (Back-thinned) detector of the QE65000 Research-Grade Raman Spectrometer has excellent UV response capability and does not require an external coating to improve its performance.; The QE65000 Research-Grade Raman Spectrometer is an excellent choice for low-light applications, including fluorescence, Raman spectroscopy, DNA sequencing, astronomy, and thin-film reflection. As needed, users can set the spectrometer's integration time (similar to a camera's shutter speed) to a value within 8 ms–15 min without optical distortion. Below is an example of fluorescence analysis using the QE65000 Research-Grade Raman Spectrometer, the CUV-ALL four-way cuvette holder, and the PX-2 Xenon Light Source. Special note: In order to externally trigger the PX-2 Xenon Light Source, an HR4-BREAKOUT breakout box is also required.; Raman spectrum of an acetaminophen solid; this experiment used the QE65000 Research-Grade Spectrometer, a 785 nm laser, and a Raman probe.; User-Programmable Input/Output Ports; The module included with the QE65000 Research-Grade Raman Spectrometer contains 10 user-programmable digital input/output ports to facilitate connection with other devices; it also contains a pulse generator that can trigger other devices. During the spectrometer's integration period, users can use these input/output ports to turn on light sources, start or stop a process, or send messages and prompts. The operating parameters of the spectrometer can be controlled via software. In fact, the wavelength calibration coefficients specific to each spectrometer are also set in the spectrometer's memory chip.; Specifications of the QE65000 Research-Grade Raman Spectrometer; Physical Appearance of the Spectrometer; Dimensions; 182 mm x 110 mm x 47 mm; Weight; 1050 g; Spectrometer Detector; Detector Model; Hamamatsu S7031-1006; Detection Range; 200-1100 nm; Pixels; 1024 x 58 (total pixels 1044 x 64); Total size 24.6 square micrometers; Pixel Size; 24.576 square micrometers; Pixel Well Depth; 300000 electrons/pixel; 1500000 electrons/column; Sensitivity; 250 nm wavelength: 26 photons/count; other wavelengths: 22 electrons/count; Quantum Efficiency; 90% peak; Spectrometer Optical Bench; Design; f/4, crossed asymmetric Czerny-Turner optical path; Focal Length; 101.6 mm for both input and output; Entrance Aperture; slits of 5, 10, 25, 50, 100, or 200 μm width, or optical fiber (no slit); Optional Gratings; 14 optional gratings, UV to near-infrared; HC-1 Grating; Spectral Range 200–950 nm; Optional Detector Condenser Lens; None; Optional OFLV Filter; OFLV-QE Filter; Other Filters; Longpass OF-1 series filters; Calibration and Condenser Mirror; Standard; UV-Enhanced; Fiber Connection; SMA905 connector, connected to 0.22 aperture single-strand optical fiber; Optical Characteristics of the Spectrometer; Wavelength; Determined by grating; Fiber Resolution; 0.14–7.7 nm full width at half maximum (FWHM); Signal-to-Noise Ratio; 1000:1 (at full signal); A/D Conversion Resolution; 16-bit; Dark Noise; 3 RMS counts; Dynamic Range; 7.5 x 10^9 (system), 25000:1 (single operation); Integration Time; 8 ms–15 min; Optical Drift; Less than 0.08% at 600 nm; 0.4% at 435 nm; Corrected Linearity; >99.8%; Electronic Characteristics; Power Consumption; 5

Key Features

SmartRaman Portable Raman Spectrometer;SmartRaman-Q Portable Raman Spectrometer;Raman Spectrometer Probe RIP;QE65000 Research-Grade Raman Spectrometer;Pinpointer Handheld Raman Spectrometer

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Gz
Gzbiaoqi
View Supplier →
Guangzhou Biaoqi Optoelectronics Technology Development Co., Ltd. was founded in 2005 and is an enterprise founded by leading entrepreneurial talents in Guangzhou Development District. It is a national high-tech enterprise and a national specialized and sophisticated "little giant" enterprise focusing on spectral rapid detection system integration and instrument development. The company integrates design, R&D, manufacturing, sales, and after-sales service, with spectral rapid detection and analysis technology as its core. Through high-speed acquisition, processing, and algorithm analysis of spectral data, it provides rapid, non-destructive, online, fully automatic detection equipment and high-end quality inspection and analysis solutions for various industries. Biaoqi Optoelectronics has established the Guangdong Provincial Engineering Technology Research Center for Rapid Spectral Measurement. Its products cover many fields such as optical component inspection, semiconductors, new energy vehicles, environmental monitoring, solar photovoltaics, new materials, biology, optoelectronics, and chemicals. Relying on strong independent R&D capabilities and independent demonstrative diversified operational advantages, Biaoqi Optoelectronics has achieved rapid development in recent years and is a leader in the domestic spectral rapid detection application industry. It has obtained numerous qualifications and honors, including national specialized and sophisticated "little giant" enterprise, national high-tech enterprise, Guangdong Province specialized and sophisticated enterprise, Guangdong Province intellectual property demonstration enterprise, and Guangzhou Development District gazelle enterprise. Under the guidance of its core corporate values of "prudent thinking, earnest practice, innovation, and win-win", Biaoqi Optoelectronics continuously accumulates experience, builds a domestic independent brand, and customizes spectral detection application solutions for customers, developing spectral rapid detection and analysis instruments suitable for different application fields. These include the optical component inspection industry: optical component spectral sorting instruments, reflectance spectral analyzers, transmittance spectral analyzers, etc.; the jewelry identification industry: UV-visible spectral analyzers (jewelry detectors), jewelry luminescence imaging analyzers, etc.; and the scientific research field: quantum efficiency spectral analysis systems, portable Raman spectral analyzers, photoluminescence spectral analyzers, etc. Biaoqi Optoelectronics' non-destructive rapid spectral analyzers have significant advantages, featuring high efficiency, speed, and accuracy, which can help users greatly improve detection efficiency and assist the high-quality development of application industries. At the same time, Biaoqi Optoelectronics is the South China general agent for Ocean Optics, the inventor of micro fiber optic spectrometers, an internationally renowned enterprise. With the rapid development of science and technology, Biaoqi Optoelectronics keeps pace with technological progress and the development of the times, forging ahead on the road of rapid spectral detection, striving for perfection.

Request a Quote

Our team responds within 24–48 hours
QE65000 Research-Grade Raman Spectrometer
Gzbiaoqi · Spectrometers
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →