JW18001-ISO Isolator Test System
Jiahui JW18001–Isolator Comprehensive Test Platform integrates various equipment such as light sources, optical switches, polarization controllers, translation stages, collimators, power meters, extinction ratio testers, etc. Designed for automated testing of parameters of isolators and related components. According to different combinations of equipment, it can measure various isolator-related components such as finished isolators, polarizers, Faraday rotators, etc. Up to 81 small-particle products can be measured at one time. It also supports multi-point scanning testing of large-sheet products. The software supports more custom operations, can save test data, and also supports protocol communication. Designed for automated testing of parameters of isolators and related components. According to different combinations of equipment, it can measure various isolator-related components such as finished isolators, polarizers, Faraday rotators, etc. Up to 81 small-particle products can be measured at one time. It also supports multi-point scanning testing of large-sheet products. The software supports more custom operations, can save test data, and also supports protocol communication.
Overview
Specifications
| Parameter | Value |
|---|---|
| Center Wavelength | 1270 nm&1290 nm&1310 nm&1330 nm |
| Light Source Type | DFB Laser |
| Output Optical Power | 5mw |
| Center Wavelength | ±1 nm |
| Light Source Power Stability at 23℃ [23℃;15min] | ±0.005 dB (15 min) |
| Light Source Power Stability at 23℃ [23℃;8h] | ±0.05 dB (8 h) |
| Wavelength Range [Standard 2.0 Optical Power Meter Probe] | 850~1700 nm |
| Optical Power Meter Test Range [Standard 2.0 Optical Power Meter Probe] | +5 dBm~-60 dBm~ |
| Linearity [Standard 2.0 Optical Power Meter Probe] | ±0.04 dB |
| Total Uncertainty [Standard 2.0 Optical Power Meter Probe] | ±3 % |
| Isolator Insertion Loss Uncertainty [Standard 2.0 Optical Power Meter Probe] | 0.05db |
| Optical Switch Channels | Up to 4 channels |
| Optical Interface | FC/APC |
| Fiber Type | 9/125 |
| Operating Wavelength [Single-mode] | Single-mode: 1260~1650 nm |
| Insertion loss | <1.2 dB; typical value 1 dB |
| Switching Time | 50 ms |
| Repeatability | 0.02 dB |
| Lifetime | ≥3×10⁷ times |
| Operating Power Supply | 220 V AC |
| Warm-up Stabilization Time | 15 min |
| Recommended Calibration Cycle | 18 months |
| Operating Temperature | 5~40 ℃ |
| Storage Temperature | -10~70 ℃ |