FTBx-1750/OHS-1700
The FTBx-1750/OHS-1700 is a high-performance power meter and optical head series designed for fast, accurate, and flexible power measurement in a platform-based solution.
Specification Snapshot
Wavelength range (nm) FTBx-1750-031-1/2/4
800 to 1700
Wavelength resolution (nm) FTBx-1750-031-1/2/4
0.01
Wavelength range (nm) FTBx-1750-02X-1/2/4
800 to 1660
Wavelength resolution (nm) FTBx-1750-02X-1/2/4
0.01
Wavelength range (nm) FTBx-1750-ISP-1
800 to 1700
Power range (dBm) (typical) FTBx-1750-ISP-1
25 to -55
Request a Quote
Download Datasheet
Chat
Overview
The FTBx-1750/OHS-1700 is a high-performance power meter and optical head series designed for fast, accurate, and flexible power measurement in a platform-based solution.
Specifications
| Parameter | Value |
|---|---|
| Number of detectors FTBx-1750-031-1/2/4 | 1/2/4 |
| Detector type FTBx-1750-031-1/2/4 | InGaAs |
| Detector size FTBx-1750-031-1/2/4 | 1mm detector |
| Wavelength range (nm) FTBx-1750-031-1/2/4 | 800 to 1700 |
| Power range (dBm) (typical) FTBx-1750-031-1/2/4 | 7 to -85 (8 to -90) |
| Uncertainty FTBx-1750-031-1/2/4 | ±(5% + 3pW) |
| Uniformity (dB) FTBx-1750-031-1/2/4 | N/A |
| Polarization-dependent responsivity (dB) FTBx-1750-031-1/2/4 | ±0.015 typical |
| Linearity (dB) FTBx-1750-031-1/2/4 | ±0.015 dB (4dBm to -55dBm) |
| Wavelength resolution (nm) FTBx-1750-031-1/2/4 | 0.01 |
| Stabilization time (ms) FTBx-1750-031-1/2/4 | 0.3 |
| Sampling rate (samples/channel) FTBx-1750-031-1/2/4 | Up to 5208 |
| Trigger input voltage (Vdc) FTBx-1750-031-1/2/4 | 0-5 (TTL-type) |
| Analog output voltage (Vdc) (typical) FTBx-1750-031-1/2/4 | N/A |
| Fiber type (um) FTBx-1750-031-1/2/4 | 5/125 to 62.5/125 |
| Number of detectors FTBx-1750-02X-1/2/4 | 1/2/4 |
| Detector type FTBx-1750-02X-1/2/4 | GeX |
| Detector size FTBx-1750-02X-1/2/4 | 3mm detector |
| Wavelength range (nm) FTBx-1750-02X-1/2/4 | 800 to 1660 |
| Power range (dBm) (typical) FTBx-1750-02X-1/2/4 | 22 to -53 (22 to -60) |
| Uncertainty FTBx-1750-02X-1/2/4 | ±(5% + 3nW) |
| Uniformity (dB) FTBx-1750-02X-1/2/4 | N/A |
| Polarization-dependent responsivity (dB) FTBx-1750-02X-1/2/4 | ±0.015 typical |
| Linearity (dB) FTBx-1750-02X-1/2/4 | ±0.015 dB (5dBm to -37dBm) |
| Wavelength resolution (nm) FTBx-1750-02X-1/2/4 | 0.01 |
| Stabilization time (ms) FTBx-1750-02X-1/2/4 | 5.0 |
| Sampling rate (samples/channel) FTBx-1750-02X-1/2/4 | Up to 5208 |
| Trigger input voltage (Vdc) FTBx-1750-02X-1/2/4 | 0-5 (TTL-type) |
| Analog output voltage (Vdc) (typical) FTBx-1750-02X-1/2/4 | 0-5 |
| Fiber type (um) FTBx-1750-02X-1/2/4 | 5/125 to 62.5/125 |
| Number of detectors FTBx-1750-ISP-1 | 1 |
| Detector type FTBx-1750-ISP-1 | InGaAs and integrating cavity |
| Detector size FTBx-1750-ISP-1 | 9mm input aperture |
| Wavelength range (nm) FTBx-1750-ISP-1 | 800 to 1700 |
| Power range (dBm) (typical) FTBx-1750-ISP-1 | 25 to -55 |
| Uncertainty FTBx-1750-ISP-1 | ±(5% + 3nW) |
| Uniformity (dB) FTBx-1750-ISP-1 | 0.05 |
| Polarization-dependent responsivity (dB) FTBx-1750-ISP-1 | ±0.008 typical |
| Linearity (dB) FTBx-1750-ISP-1 | ±0.015 dB (5dBm to -38dBm) ±0.075 dB (23dBm to 5dBm) |
| Wavelength resolution (nm) FTBx-1750-ISP-1 | 0.01 |
| Stabilization time (ms) FTBx-1750-ISP-1 | 0.4 |
| Sampling rate (samples/channel) FTBx-1750-ISP-1 | Up to 5208 |
| Trigger input voltage (Vdc) FTBx-1750-ISP-1 | 0-5 (TTL-type) |
| Analog output voltage (Vdc) (typical) FTBx-1750-ISP-1 | 0-5 |
| Fiber type (um) FTBx-1750-ISP-1 | 5/125 to 62.5/125 |
| Number of detectors OHS-1713-UH | 1 |
| Detector type OHS-1713-UH | InGaAs and integrating cavity |
| Detector size OHS-1713-UH | 9mm input aperture |
| Wavelength range (nm) OHS-1713-UH | 850 to 1660 |
| Power range (dBm) (typical) OHS-1713-UH | 37 to -55 |
| Uncertainty OHS-1713-UH | ±(5% + 3nW) |
| Uniformity (dB) OHS-1713-UH | 0.05 |
| Polarization-dependent responsivity (dB) OHS-1713-UH | ±0.008 typical |
| Linearity (dB) OHS-1713-UH | ±0.011 dB (35dBm to 30dBm) ±0.05 dB (30dBm to 5dBm) ±0.08 dB (5dBm to -22dBm) |
| Wavelength resolution (nm) OHS-1713-UH | 0.01 |
| Stabilization time (ms) OHS-1713-UH | 0.3 |
| Sampling rate (samples/channel) OHS-1713-UH | Up to 5208 |
| Trigger input voltage (Vdc) OHS-1713-UH | 0-5 (TTL-type) |
| Analog output voltage (Vdc) (typical) OHS-1713-UH | N/A |
| Fiber type (um) OHS-1713-UH | 5/125 to 62.5/125 |
Applications
1. High-speed optical power measurement 2. Remote high-power testing 3. R&D and manufacturing environments 4. Automated test stations
Key Features
1. High-speed acquisition with extended range 2. Data acquisition on single or multiple channels 3. User-configurable trigger input and analog output 4. Ultra-high-power remote head for up to 37dBm measurement 5. Continuous sampling rate of up to 5208 samples per second
Datasheet
Product Datasheet
PDF
Supplier Information
<p>EXFO develops smarter test, monitoring and analytics solutions for the global communications industry. As a trusted advisor, we serve fixed and mobile network operators, hyperscale data centers, and leaders in production and R&D. We provide insights into superior network performance, service reliability, and user experience. Backed by 40 years of innovation, EXFO uniquely combines equipment, software and services to enable customers to upgrade 5G, cloud-native and fiber networks faster and more reliably.</p>
Contact Us
Loading...
GetExperimental Plan
Name
Phone
+86
Organization
Use Case

Global Photonics Products
Database Platform
Database Platform
With 16 years of experience, we provide high-quality products and services to universities, research institutes, and industry.
50+ Detailed Categories · 3,000+ Global Brands · 100,000+ Photonics Products
1 Million+
In-depth analysis of professional academic resources in photonics
300,000
ProductsDatasheets Available Free
We will keep your personal information strictly confidential.
Product Quote
+86
* Select the quoting party:
By submitting, you agree to the User Service Agreement and Privacy Policy