UT273C钳形接地电阻测试仪
UT 273C ground-to-ground resistance testers use new designs, electrical resistance currents and screen displays, as well as real-time clocks, data storage, data access, alarms, automatic shutdowns, etc., wide range, resolution, operation, ease of transport, accuracy, reliability, performance stability, and high ability to resist interference. When measuring a back-to-ground system, there is no need for unconnected lead, no need for auxiliary poles, safe and easy use, and extensive use for measuring all kinds of telecommunications, electricity, weather, mechanical buildings, oil fields, electrical distribution lines, iron tower transmission lines, refuelling stations, plant connections, lightning-proofing needles, etc.
Overview
Specifications
| Parameter | Value |
|---|---|
| Retardation - scale range | 0.010 Ω-0.099 Ω |
| Resist - Resolution @ 0.010Ω-0.099Ω | 0.001 Ω |
| Resist - Accuracy @ 0.010Ω-0.099Ω | ±(1%rdg+0.01Ω) |
| Retardation - scale range | 0.10 Ω-0.99 Ω |
| Resist - Resolution @ 0.10Ω-0.99Ω | 0.01 Ω |
| Resist - Accuracy @ 0.10Ω-0.99Ω | ±(1%rdg+0.01Ω) |
| Retardation - scale range | 1.0 Ω-49.9 Ω |
| Resist - Resolution @ 1.0Ω-49.9Ω | 0.1 Ω |
| Resist - Accuracy @ 1.0Ω-49.9Ω | ±(1%rdg+0.1Ω) |
| Retardation - scale range | 50.0 Ω-99.5 Ω |
| Resist - Resolution @ 50.0Ω-99.5Ω | 0.5 Ω |
| Resist - Accuracy @ 50.0Ω-99.5Ω | ±(1.5%rdg+0.5Ω) |
| Retardation - scale range | 100 Ω-199 Ω |
| Resist - Resolution @ 100Ω-199Ω | 1 Ω |
| Resist - Accuracy @ 100Ω-199Ω | ±(2%rdg+1Ω) |
| Retardation - scale range | 200 Ω-395 Ω |
| Resist - Resolution @ 200Ω-395Ω | 5 Ω |
| Resist - Accuracy @ 200Ω-395Ω | ±(5%rdg+5Ω) |
| Retardation - scale range | 400 Ω-590 Ω |
| Resist - Resolution @ 400Ω-590Ω | 10 Ω |
| Resist - Accuracy @ 400Ω-590Ω | ±(10%rdg+10Ω) |
| Retardation - scale range | 600 Ω-980 Ω |
| Resist - Resolution @ 600Ω-980Ω | 20 Ω |
| Resist - Accuracy @ 600Ω-980Ω | ±(20%rdg+20Ω) |
| Retardation - scale range | 1000 Ω-1200 Ω |
| Resist - Resolution @ 1000Ω-1200Ω | 30 Ω |
| Resist - Accuracy @ 1000Ω-1200Ω | ±(25%rdg+30Ω) |
| Electricity - Scale | 0.00 mA -9.99 mA |
| Electricity - Resolution @ 0.00mA -9.99mA | 0.01 mA |
| Electricity - Accuracy @ 0.00mA -9.99mA | ±(2.5%rdg+1mA) |
| Electricity - Scale | 10.0 mA -99.9 mA |
| Electricity - Resolution @ 10.0mA -99.9mA | 0.1 mA |
| Electricity - Accuracy @ 10.0mA -99.9mA | ±(2.5%rdg+5mA) |
| Electricity - Scale | 100 mA -299 mA |
| Electricity - Resolution @ 100mA -299mA | 1 mA |
| Electricity - Accuracy @ 100mA -299mA | ±(2.5%rdg+10mA) |
| Electricity - Scale | 0.30 A-2.99 A |
| Electricity - Resolution @ 0.30A-2.99A | 0.01 A |
| Electricity - Accuracy @ 0.30A-2.99A | ±(2.5%rdg+0.1A) |
| Electricity - Scale | 3.0 A-9.9 A |
| Electricity - Resolution @ 3.0A-9.9A | 0.1 A |
| Electricity - Accuracy @ 3.0A-9.9A | ±(2.5%rdg+0.3A) |
| Electricity - Scale | 10.0 A-20.0 A |
| Electricity - Resolution @ 10.0A-20.0A | 0.1 A |
| Electricity - Accuracy @ 10.0A-20.0A | ±(2.5%rdg+0.5A) |
| Function | Ground-based resistance testing, circuit resistance testing, leaking current testing |
| Power Supply | DC 6 V,5 No. B.L.B.B. (LR6 1.5 V AA×4) |
| Method of measurement | The way we feel each other. |
| Resist resolution | 0.001 Ω |
| Current Resolution | 0.01 mA |
| Pistol size | 55 mm×32 mm |
| Clock function | Yes |
| Ω + A Synchronise Display | Ω + A Show on-screen |
| Show Mode | 4-bit LCD display |
| LCD Size | 46 mm×36 mm |
| Instrument Dimensions | 288 mm×98 mm×56 mm |
| Measurement Time | 1 sec/s |
| UsB Interface | With USB interfaces, stored data can be uploaded to the computer, and print saved |
| Bluetooth. | Yes |
| Communication lines | USB 1 line of communication |
| Data Storage | Group 500, "MEM" storage instruction, blinking to indicate that the "MEM" symbol indicates that the storage is full. |
| Data access | The "MR" symbol indicator when accessing data |
| Spill display | "OL" symbol indicator for excess-range spills |
| Interference test | Automatically recognize jamming signals, and interfere with NOISE symbol when electrical current is high |
| Alarm function | Send a warning when the measured value exceeds the alarm default. |
| Cell voltage | Battery power low alarm |
| Auto-Close | You can set it in 5, 10, 15, 20 minutes, OFF, OFF means you can cancel the automatic switch-off, and the default is 5 minutes. |
| Power Consumption Line Power | Max Approximately 80 mA |
| Quality | Instrument: 895 g (including batteries) |
| Temperature of work | min: -10;max: 40 |
| Store Temperature | min: -20;max: 60 |
| Insulation Resistance | 20MΩ Above (Between the circuit and the shell. 500V) |
| Pressure Resistance | AC 3700 V/rms (between circuit and shell) |
| External magnetic field | <40 A/m |
| External electric field | <1 V/m |
| It's good for security. | IEC 61010-1 (CAT III 300 V, CAT IV 150 V, Pollution Degree 2) |
| It's good for security. | IEC 61010-031; IEC 61557-1 (terrestrial electrical resistance); JJG 1054-2009 Cracker electrical resistor inspection protocol |
Key Features
Datasheet
Supplier Information
Loading...
Name
Phone
Organization
Use Case

Database Platform