USB communication replaces an industrial PC with an ordinary computer to lower cost. The source describes a convenient2U housing,48-channel light-string testing and rapid simultaneous multiparameter measurement. One versatile board serves sorters/taping machines for easy maintenance/use. Two voltage ranges provide precise0–300V output/measurement; two current ranges cover0–100mA. Fast processing/transfer meets30K tests per hour. The listed configuration is FC2000 filament-lamp test/sorting system + ordinary PC + standard4U chassis. It is offered as a professional, precise, low-cost, convenient filament-test sorter solution, retaining the2U/4U descriptions.

Specification Snapshot
DW Dominant Wavelength Measurement Range [Special Wavelength Ranges Customizable]
380nm~780nm
DW Dominant Wavelength Measurement Accuracy [Special Precision Customizable]
1nm
Test Speed
(Set Delay +5ms)*Number of Filaments
Communication Interface [Suitable for Ordinary Computer Motherboards]
USB2.0 Interface, RS232 Interface
Dimensions (2U Chassis)
310mm*220mm
Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

USB communication replaces an industrial PC with an ordinary computer to lower cost. The source describes a convenient2U housing,48-channel light-string testing and rapid simultaneous multiparameter measurement. One versatile board serves sorters/taping machines for easy maintenance/use. Two voltage ranges provide precise0–300V output/measurement; two current ranges cover0–100mA. Fast processing/transfer meets30K tests per hour. The listed configuration is FC2000 filament-lamp test/sorting system + ordinary PC + standard4U chassis. It is offered as a professional, precise, low-cost, convenient filament-test sorter solution, retaining the2U/4U descriptions.

Specifications

ParameterValue
Test ParametersPOL、VF、IF、mcd、lm、(x,y)、DW、CCT、Ra
Applicable Lamp TypesLED Filament Lamps, up to 48 Channels
Number of I/OsSOT 3 Positions; EOT 1 Position; PIN Number 9 Positions
Forward Current Output Range Settings and Accuracy20mA Range(0.01mA)----0.3% of Range±3 Counts;100mA Range(0.1mA)----0.3% of Range±3 Counts
Forward Current Test Range Settings and Accuracy20mA Range(0.01mA)----0.3% of Range±3 Counts;100mA Range(0.1mA)----0.3% of Range±3 Counts
Forward Voltage Output Range Settings and Accuracy0-100V(0. 1V)-----0.1% of Range ±3 Reading Counts; 100-300V(0.5V)-----0.5% of Range ±3 Reading Counts
Forward Voltage Test Range Settings and Accuracy0-100V(0. 1V)-----0.1% of Range ±3 Reading Counts; 100-300V(0.5V)-----0.5% of Range ±3 Reading Counts
mcd Test Range [Tested with Light Intensity Device]0-20000mcd
mcd Test Accuracy [Compared with Third-Party Laboratory Test Data]<3%
lm Test Range [Tested with Different Integrating Spheres]0-15000lm
lm Test Accuracy [Compared with Third-Party Laboratory Test Data]<3%
DW Dominant Wavelength Measurement Range [Special Wavelength Ranges Customizable]380nm~780nm
DW Dominant Wavelength Measurement Accuracy [Special Precision Customizable]1nm
CCT Correlated Color Temperature Measurement Range1500K-25000K
CCT Correlated Color Temperature Measurement Accuracy [@6500K]0.8%@6500K
Ra Color Rendering Index Measurement Range0~100
Ra Color Rendering Index Measurement Accuracy1
Test Speed(Set Delay +5ms)*Number of Filaments
Communication Interface [Suitable for Ordinary Computer Motherboards]USB2.0 Interface, RS232 Interface
Power SupplyAC220V/1A
Dimensions (2U Chassis)310mm*220mm

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Lc
Lcdfly
View Supplier →
Hangzhou Jingfei Technology Co., Ltd. (Jingfei Technology) was founded in 2008, is a leading supplier of miniature fiber optic spectrometers and optical testing solutions in China. As a national high-tech enterprise and a specialized and sophisticated SME in Zhejiang Province, the company focuses on independent R&D and innovation in spectral analysis technology, holding multiple invention patents, utility model patents, and software copyrights. Its products are widely used in optical inspection, energy and environmental protection, biomedicine, food safety, agricultural science, industrial manufacturing, etc. In LED spectral binning market, it holds over 85% market share, achieving import substitution; in thin-film thickness measurement, its high-precision spectrometers have become key equipment in photovoltaic and display panel production lines; in semiconductor manufacturing, its spectral detection technology is applied in wafer fabrication and packaging testing. The company's FLA series miniature fiber optic spectrometers have reached international advanced levels. Jingfei Technology adheres to the concept of 'innovation-driven development', continuously enhancing the core competitiveness of domestic scientific instruments, and promoting the development of the national instrument industry.

Request a Quote

Our team responds within 24–48 hours
FLC2000 Test System for Filament Sorting Machines
Lcdfly · Custom and Other Services
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →