FLC2000 Test System for Filament Sorting Machines
USB communication replaces an industrial PC with an ordinary computer to lower cost. The source describes a convenient2U housing,48-channel light-string testing and rapid simultaneous multiparameter measurement. One versatile board serves sorters/taping machines for easy maintenance/use. Two voltage ranges provide precise0–300V output/measurement; two current ranges cover0–100mA. Fast processing/transfer meets30K tests per hour. The listed configuration is FC2000 filament-lamp test/sorting system + ordinary PC + standard4U chassis. It is offered as a professional, precise, low-cost, convenient filament-test sorter solution, retaining the2U/4U descriptions.
Overview
Specifications
| Parameter | Value |
|---|---|
| Test Parameters | POL、VF、IF、mcd、lm、(x,y)、DW、CCT、Ra |
| Applicable Lamp Types | LED Filament Lamps, up to 48 Channels |
| Number of I/Os | SOT 3 Positions; EOT 1 Position; PIN Number 9 Positions |
| Forward Current Output Range Settings and Accuracy | 20mA Range(0.01mA)----0.3% of Range±3 Counts;100mA Range(0.1mA)----0.3% of Range±3 Counts |
| Forward Current Test Range Settings and Accuracy | 20mA Range(0.01mA)----0.3% of Range±3 Counts;100mA Range(0.1mA)----0.3% of Range±3 Counts |
| Forward Voltage Output Range Settings and Accuracy | 0-100V(0. 1V)-----0.1% of Range ±3 Reading Counts; 100-300V(0.5V)-----0.5% of Range ±3 Reading Counts |
| Forward Voltage Test Range Settings and Accuracy | 0-100V(0. 1V)-----0.1% of Range ±3 Reading Counts; 100-300V(0.5V)-----0.5% of Range ±3 Reading Counts |
| mcd Test Range [Tested with Light Intensity Device] | 0-20000mcd |
| mcd Test Accuracy [Compared with Third-Party Laboratory Test Data] | <3% |
| lm Test Range [Tested with Different Integrating Spheres] | 0-15000lm |
| lm Test Accuracy [Compared with Third-Party Laboratory Test Data] | <3% |
| DW Dominant Wavelength Measurement Range [Special Wavelength Ranges Customizable] | 380nm~780nm |
| DW Dominant Wavelength Measurement Accuracy [Special Precision Customizable] | 1nm |
| CCT Correlated Color Temperature Measurement Range | 1500K-25000K |
| CCT Correlated Color Temperature Measurement Accuracy [@6500K] | 0.8%@6500K |
| Ra Color Rendering Index Measurement Range | 0~100 |
| Ra Color Rendering Index Measurement Accuracy | 1 |
| Test Speed | (Set Delay +5ms)*Number of Filaments |
| Communication Interface [Suitable for Ordinary Computer Motherboards] | USB2.0 Interface, RS232 Interface |
| Power Supply | AC220V/1A |
| Dimensions (2U Chassis) | 310mm*220mm |
Datasheet