YC100W Horizontal Interferometer (4-Inch)

YC100W Horizontal Interferometer (4-Inch)

Supplier
Ycgx
Part Number
YC100W
Category
Interferometers
Origin
China

The YC100W laser interferometer has a clear aperture of φ101.6 mm, a high-precision imaging system, and good vibration isolation. It meets measurement needs for large-aperture, highly curved lenses and high-precision optical components and systems. Motorized 1-7X image zoom and motorized focusing make testing more convenient and efficient. Standard lenses include F0.65, F0.75, F1.0, F1.5, F2.2, F3.3, F5.0, F7.1, F10.7, F15, F25, F45, F10D, F15D, F25D, F45D, and TF flat lenses. Other F-number lenses can be customized.

Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

The YC100W laser interferometer has a clear aperture of φ101.6 mm, a high-precision imaging system, and good vibration isolation. It meets measurement needs for large-aperture, highly curved lenses and high-precision optical components and systems. Motorized 1-7X image zoom and motorized focusing make testing more convenient and efficient. Standard lenses include F0.65, F0.75, F1.0, F1.5, F2.2, F3.3, F5.0, F7.1, F10.7, F15, F25, F45, F10D, F15D, F25D, F45D, and TF flat lenses. Other F-number lenses can be customized.

Specifications

ParameterValue
Interferometric Principle [Respective Parameter Image 01; YC100W Complete Unit/Configuration]Fizeau Type
System Accuracy [Respective Parameter Image 01; YC100W Complete Unit/Configuration]Better than λ/20
Effective Beam Diameter [Respective Parameter Image 01; YC100W Complete Unit/Configuration]4 Inches (101.6mm)
Test Wavelength [Individual Parameter Image 01; YC100W Complete Instrument/Configuration; Imported He-Ne Laser]632.8 nm
Standard Spherical Lens Accuracy [Individual Parameter Image 01; YC100W Complete Instrument/Configuration; @632.8nm; Optional]λ/15 and λ/20
Standard Plane Lens Accuracy [Individual Parameter Image 01; YC100W Complete Instrument/Configuration; @632.8nm]Better than λ/20
Standard Plane Lens Material [Respective Parameter Image 01; YC100W Complete Unit/Configuration]Imported Fused Silica
Material Homogeneity [Individual Parameter Image 01; YC100W Complete Instrument/Configuration; Standard Plane Lens]Better than 2
Material Stress [Individual Parameter Image 01; YC100W Complete Instrument/Configuration; Standard Plane Lens]Better than 2
PV Repeatability [Respective Parameter Image 01; YC100W Complete Unit/Configuration]<0.01λ
RMS Repeatability [Respective Parameter Image 01; YC100W Complete Unit/Configuration]<0.002λ
Instrument Dimensions [Individual Parameter Image 01; YC100W Complete Instrument/Configuration; Length×Width×Height]650 mm × 310 mm × 450 mm
Instrument Weight [Respective Parameter Image 01; YC100W Complete Unit/Configuration]Approximately 65
Operating Power Supply [Respective Parameter Image 01; YC100W Complete Unit/Configuration]AC100~240V/5A/50/60Hz
Image Analysis [Respective Parameter Image 01; YC100W Complete Unit/Configuration]2/3 Inch; Resolution ≥2K×2K
Image Zoom Mode [Respective Parameter Image 01; YC100W Complete Unit/Configuration]Motorized Continuous Zoom 1~7X
Image Focusing Mode [Respective Parameter Image 01; YC100W Complete Unit/Configuration]Motorized
Interference Fringe Analysis Software (Dynamic) [Respective Parameter Image 01; YC100W Complete Unit/Configuration]Optional
Phase-Shifting Method [Respective Parameter Image 01; YC100W Complete Unit/Configuration]Piezoelectric Ceramic Mechanical Phase Shifting
Ambient Vibration Requirements [Respective Parameter Image 01; YC100W Complete Unit/Configuration]Avoid Measurement Environment Vibration of 1~130
Ambient Temperature Requirements [Individual Parameter Image 01; YC100W Complete Instrument/Configuration; Optimal Measurement Performance]20±2 °C
Ambient Temperature Variation Requirements [Respective Parameter Image 01; YC100W Complete Unit/Configuration]<0.5 °C/h
Ambient Humidity Requirements [Individual Parameter Image 01; YC100W Complete Instrument/Configuration; Relative Humidity]50~65 %
Total System Travel [Respective Parameter Image 01; YC100W Complete Unit/Configuration]Determined by the Length of the Specifically Configured Optical Table
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F0.65]38 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F0.65; Convex]4~33 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F0.65; Concave]4~465 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F0.65; Convex]50 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F0.65; Concave]238 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F0.75]48 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F0.75; Convex]5~40 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F0.75; Concave]5~540 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F0.75; Convex]53 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F0.75; Concave]238 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F1.0]65 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F1.0; Convex]7~60 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F1.0; Concave]7~720 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F1.0; Convex]60 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F1.0; Concave]238 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F1.5]121 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F1.5; Convex]12~116 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F1.5; Concave]12~1080 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F1.5; Convex]77 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F1.5; Concave]238 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F2.2]191 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F2.2; Convex]19~188 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F2.2; Concave]19~990 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F2.2; Convex]85 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F2.2; Concave]238 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F3.3]298 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F3.3; Convex]30~295 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F3.3; Concave]30~1102 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F3.3; Convex]89 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F3.3; Concave]238 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F5.0]490 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F5.0; Convex]49~487 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F5.0; Concave]49~910 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F5.0; Convex]97 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F5.0; Concave]180 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F7.1]682 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F7.1; Convex]68~679 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F7.1; Concave]68~718 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F7.1; Convex]95 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F7.1; Concave]99 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F10.7]1039 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F10.7; Convex]104~1036 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F10.7; Concave]104~360 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F10.7; Convex]96 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F10.7; Concave]33 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F15]1515 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F15; Convex]152~1512 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F15; Convex]99 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F25]2500 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F25; Convex]1100~2497 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F25; Convex]99 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F45]4500 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F45; Convex]3100~4497 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F45; Convex]99 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F10D]1025 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F10D; Concave]1028~2425 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F10D; Concave]236 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F15D]1500 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F15D; Concave]1503~2900 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F15D; Concave]191 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F25D]2454 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F25D; Concave]2457~3900 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F25D; Concave]153 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F45D]4500 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F45D; Concave]4503~5900 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F45D; Concave]127 mm
Reference mirror radius of curvature [Lens Configuration; F-Number=TF; Other Ranges Missing]Plane

Applications

Measures Surface Fringe Count and Local yasi (Source Term) of Spherical Elements, Including Glass/Plastic Lenses, Mirrors, Fringe Gauges and Spherical Bearings; Also Measures These Properties on Planar Elements Such as Plane Mirrors, Crystals, Ceramics and Gauge Blocks.

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Suzhou Yuchuan Optical Technology Co., Ltd. was established on May 2, 2012, and is currently located in the Changshun Chuanggu Industrial Park, Jinfeng Town, Zhangjiagang City, Jiangsu Province. With decades of working background in foreign enterprises and professional technical strength, the team has always adhered to the service tenet of 'unity, pragmatism, innovation, and trustworthiness' and the quality philosophy of 'excellence based on precision, winning by quality' to keep forging ahead. It has established good cooperative relationships with more than 300 domestic and foreign enterprises. The company specializes in the production and sales of high-precision optical components and optical templates, as well as the R&D, design, production, and sales of optical inspection equipment, providing a one-stop service. The products are applied in fields such as optical parts processing enterprises, projection, image capture, artificial intelligence & industrial equipment, and lighting systems. The company owns multiple imported processing equipment and measuring instruments, ensuring the precision and quality reliability of products.

Request a Quote

Our team responds within 24–48 hours
YC100W Horizontal Interferometer (4-Inch)
Ycgx · Interferometers
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →