The YC100D laser interferometer has a clear aperture of Φ101.6 mm, a high-precision imaging system, and good vibration isolation. It suits high-volume shop-floor inspection of optical lenses and precision measurements in optical laboratories. Motorized 1-7X image zoom and focusing make inspection more convenient and efficient. Standard lenses include F0.65/F0.75/F1.0/F1.5/F2.2/F3.3/F5.0/F7.1/F10.7/F15/F25/F45/F10D/F15D/F25D/F45D/TF flat lenses. Other F-number lenses can be customized.

Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

The YC100D laser interferometer has a clear aperture of Φ101.6 mm, a high-precision imaging system, and good vibration isolation. It suits high-volume shop-floor inspection of optical lenses and precision measurements in optical laboratories. Motorized 1-7X image zoom and focusing make inspection more convenient and efficient. Standard lenses include F0.65/F0.75/F1.0/F1.5/F2.2/F3.3/F5.0/F7.1/F10.7/F15/F25/F45/F10D/F15D/F25D/F45D/TF flat lenses. Other F-number lenses can be customized.

Specifications

ParameterValue
Interferometric Principle [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]Fizeau Type
System Accuracy [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]Better than λ/20
Effective Beam Diameter [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]4 Inches (101.6mm)
Test Wavelength [Parameter Image 01; YC100D Flagship Complete Instrument/Configuration; Imported He-Ne Laser]632.8 nm
Optical Path Switching [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]Electrically Controlled Switching Between Alignment and Testing
Response Frequency [Parameter Image 01; YC100D Flagship Complete Instrument/Configuration; Optical Path Switching; Source Name Response Frequency and Value S Retained]0.5 S
Standard Spherical Lens Accuracy [Parameter Image 01; YC100D Flagship Complete Instrument/Configuration; @632.8nm; Optional]λ/15 and λ/20
Standard Plane Lens Accuracy [Parameter Image 01; YC100D Flagship Complete Instrument/Configuration; @632.8nm]Better than λ/20
Standard Plane Lens Material [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]Imported Fused Silica
Material Homogeneity [Parameter Image 01; YC100D Flagship Complete Instrument/Configuration; Standard Plane Lens]Better than 2
Material Stress [Parameter Image 01; YC100D Flagship Complete Instrument/Configuration; Standard Plane Lens]Better than 2
Guide Rail [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]Taiwan HIWIN Brand Guide Rails
Instrument Dimensions [Parameter Image 01; YC100D Flagship Complete Instrument/Configuration; Length×Width×Height]853 mm × 551 mm × 2044 mm
Instrument Weight [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]Approximately 275
Operating Power Supply [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]AC100~240V/5A/50/60Hz
Image Analysis [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]2/3 Inch; Resolution ≥2K×2K
Image Focusing Mode [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]Manual
Test System Guide Rail Length [Parameter Image 01; YC100D Flagship Complete Instrument/Configuration; Measurement Travel]1050 mm
Inspection Fixture [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]Universal Fixture
Grating Encoder [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]Imported from Taiwan
Vibration Isolation [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]Built-In Passive Vibration Isolation
Interference Fringe Analysis Software (Dynamic) [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]Optional
Phase-Shifting Method [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]Piezoelectric Ceramic Mechanical Phase Shifting
Ambient Vibration Requirements [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]Avoid Measurement Environment Vibration of 1~130
Ambient Temperature Requirements [Parameter Image 01; YC100D Flagship Complete Instrument/Configuration; Optimal Measurement Performance]22±2 °C
Ambient Temperature Variation Requirements [Parameter Image 01; YC100D Flagship Complete Unit/Configuration]<0.5 °C/h
Ambient Humidity Requirements [Parameter Image 01; YC100D Flagship Complete Instrument/Configuration; Relative Humidity]50~65 %
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F0.65]38 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F0.65; Convex]4~33 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F0.65; Concave]4~465 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F0.65; Convex]50 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F0.65; Concave]238 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F0.75]48 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F0.75; Convex]5~40 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F0.75; Concave]5~540 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F0.75; Convex]53 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F0.75; Concave]238 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F1.0]65 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F1.0; Convex]7~60 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F1.0; Concave]7~720 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F1.0; Convex]60 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F1.0; Concave]238 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F1.5]121 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F1.5; Convex]12~116 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F1.5; Concave]12~1080 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F1.5; Convex]77 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F1.5; Concave]238 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F2.2]191 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F2.2; Convex]19~188 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F2.2; Concave]19~990 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F2.2; Convex]85 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F2.2; Concave]238 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F3.3]298 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F3.3; Convex]30~295 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F3.3; Concave]30~1102 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F3.3; Convex]89 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F3.3; Concave]238 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F5.0]490 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F5.0; Convex]49~487 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F5.0; Concave]49~910 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F5.0; Convex]97 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F5.0; Concave]180 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F7.1]682 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F7.1; Convex]68~679 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F7.1; Concave]68~718 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F7.1; Convex]95 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F7.1; Concave]99 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F10.7]1039 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F10.7; Convex]104~1036 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F10.7; Concave]104~360 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F10.7; Convex]96 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F10.7; Concave]33 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F15]1515 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F15; Convex]152~1512 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F15; Convex]99 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F25]2500 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F25; Convex]1100~2497 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F25; Convex]99 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F45]4500 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F45; Convex]3100~4497 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F45; Convex]99 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F10D]1025 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F10D; Concave]1028~2425 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F10D; Concave]236 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F15D]1500 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F15D; Concave]1503~2900 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F15D; Concave]191 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F25D]2454 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F25D; Concave]2457~3900 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F25D; Concave]153 mm
Reference mirror radius of curvature [Standard/Reference Lens Configuration; F-Number=F45D]4500 mm
Radius of curvature measurement range [Standard/Reference Lens Configuration; F-Number=F45D; Concave]4503~5900 mm
Maximum measurement aperture [Standard/Reference Lens Configuration; F-Number=F45D; Concave]127 mm
Reference mirror radius of curvature [Lens Configuration; F-Number=TF; No Numeric Range]Plane

Applications

Measures Surface Fringe Count and Local yasi (Source Term) of Spherical Elements, Including Glass/Plastic Lenses, Mirrors, Fringe Gauges and Spherical Bearings; Also Measures These Properties on Planar Elements Such as Plane Mirrors, Crystals, Ceramics and Gauge Blocks.

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Suzhou Yuchuan Optical Technology Co., Ltd. was established on May 2, 2012, and is currently located in the Changshun Chuanggu Industrial Park, Jinfeng Town, Zhangjiagang City, Jiangsu Province. With decades of working background in foreign enterprises and professional technical strength, the team has always adhered to the service tenet of 'unity, pragmatism, innovation, and trustworthiness' and the quality philosophy of 'excellence based on precision, winning by quality' to keep forging ahead. It has established good cooperative relationships with more than 300 domestic and foreign enterprises. The company specializes in the production and sales of high-precision optical components and optical templates, as well as the R&D, design, production, and sales of optical inspection equipment, providing a one-stop service. The products are applied in fields such as optical parts processing enterprises, projection, image capture, artificial intelligence & industrial equipment, and lighting systems. The company owns multiple imported processing equipment and measuring instruments, ensuring the precision and quality reliability of products.

Request a Quote

Our team responds within 24–48 hours
YC100D Interferometer (4-Inch) - Flagship Type
Ycgx · Interferometers
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →