GDTA hybrid optical/electrical cable

GDTA hybrid optical/electrical cable

Supplier
Hongan
Category
Fiber Cables & Bundles
Origin
China

GDTA (loose-tube stranded construction, metallic strength members, cable filling compound, aluminum-polyethylene bonded sheath). Applicable standard: YD/T 2159-2010, Hybrid optical/electrical cables for access networks. Notes: 1. D denotes cable diameter; 2. Corresponding technical parameters can be adjusted to customer requirements; 3. Water-blocking methods and other features can be adjusted to customer requirements; 3. Specific flame-retardant, rodent-resistant, termite-resistant and other cable designs can be provided to customer requirements.

Specification Snapshot
Outer Diameter [GDTA; Parameter image 2, row 1; Core count 24, conductor specifications 2×1.0]
12.4 mm
Weight [GDTA; Parameter image 2, row 1; Core count 24, conductor specifications 2×1.0]
155 kg/km
Outer Diameter [GDTA; Parameter image 2, row 2; Core count 24, conductor specifications 2×1.5]
14.0 mm
Weight [GDTA; Parameter image 2, row 2; Core count 24, conductor specifications 2×1.5]
196 kg/km
Outer Diameter [GDTA; Parameter image 2, row 3; Core count 24, conductor specifications 2×2.5]
13.8 mm
Weight [GDTA; Parameter image 2, row 3; Core count 24, conductor specifications 2×2.5]
238 kg/km
Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

GDTA (loose-tube stranded construction, metallic strength members, cable filling compound, aluminum-polyethylene bonded sheath). Applicable standard: YD/T 2159-2010, Hybrid optical/electrical cables for access networks. Notes: 1. D denotes cable diameter; 2. Corresponding technical parameters can be adjusted to customer requirements; 3. Water-blocking methods and other features can be adjusted to customer requirements; 3. Specific flame-retardant, rodent-resistant, termite-resistant and other cable designs can be provided to customer requirements.

Specifications

ParameterValue
Fiber Count [GDTA; Parameter image 2, row 1; Core count 24, conductor specifications 2×1.0]24
Conductor Specifications [GDTA; Parameter image 2, row 1; Core count 24, conductor specifications 2×1.0]2×1.0
Structure [GDTA; Parameter image 2, row 1; Core count 24, conductor specifications 2×1.0]1+6
Outer Diameter [GDTA; Parameter image 2, row 1; Core count 24, conductor specifications 2×1.0]12.4 mm
Weight [GDTA; Parameter image 2, row 1; Core count 24, conductor specifications 2×1.0]155 kg/km
Tensile Force [GDTA; Parameter image 2, row 1; Core count 24, conductor specifications 2×1.0; Long-term]600 N
Tensile Force [GDTA; Parameter image 2, row 1; Core count 24, conductor specifications 2×1.0; Short-term]1500 N
Crush Force [GDTA; Parameter image 2, row 1; Core count 24, conductor specifications 2×1.0; Long-term]300 N
Crush Force [GDTA; Parameter image 2, row 1; Core count 24, conductor specifications 2×1.0; Short-term]1000 N
Bend Radius [GDTA; Parameter image 2, row 1; Core count 24, conductor specifications 2×1.0; Static; D is the optical-cable diameter]10D
Bend Radius [GDTA; Parameter image 2, row 1; Core count 24, conductor specifications 2×1.0; Dynamic; D is the optical-cable diameter]20D
Fiber Count [GDTA; Parameter image 2, row 2; Core count 24, conductor specifications 2×1.5]24
Conductor Specifications [GDTA; Parameter image 2, row 2; Core count 24, conductor specifications 2×1.5]2×1.5
Structure [GDTA; Parameter image 2, row 2; Core count 24, conductor specifications 2×1.5]1+6
Outer Diameter [GDTA; Parameter image 2, row 2; Core count 24, conductor specifications 2×1.5]14.0 mm
Weight [GDTA; Parameter image 2, row 2; Core count 24, conductor specifications 2×1.5]196 kg/km
Tensile Force [GDTA; Parameter image 2, row 2; Core count 24, conductor specifications 2×1.5; Long-term]600 N
Tensile Force [GDTA; Parameter image 2, row 2; Core count 24, conductor specifications 2×1.5; Short-term]1500 N
Crush Force [GDTA; Parameter image 2, row 2; Core count 24, conductor specifications 2×1.5; Long-term]300 N
Crush Force [GDTA; Parameter image 2, row 2; Core count 24, conductor specifications 2×1.5; Short-term]1000 N
Bend Radius [GDTA; Parameter image 2, row 2; Core count 24, conductor specifications 2×1.5; Static; D is the optical-cable diameter]10D
Bend Radius [GDTA; Parameter image 2, row 2; Core count 24, conductor specifications 2×1.5; Dynamic; D is the optical-cable diameter]20D
Fiber Count [GDTA; Parameter image 2, row 3; Core count 24, conductor specifications 2×2.5]24
Conductor Specifications [GDTA; Parameter image 2, row 3; Core count 24, conductor specifications 2×2.5]2×2.5
Structure [GDTA; Parameter image 2, row 3; Core count 24, conductor specifications 2×2.5]1+4
Outer Diameter [GDTA; Parameter image 2, row 3; Core count 24, conductor specifications 2×2.5]13.8 mm
Weight [GDTA; Parameter image 2, row 3; Core count 24, conductor specifications 2×2.5]238 kg/km
Tensile Force [GDTA; Parameter image 2, row 3; Core count 24, conductor specifications 2×2.5; Long-term]600 N
Tensile Force [GDTA; Parameter image 2, row 3; Core count 24, conductor specifications 2×2.5; Short-term]1500 N
Crush Force [GDTA; Parameter image 2, row 3; Core count 24, conductor specifications 2×2.5; Long-term]300 N
Crush Force [GDTA; Parameter image 2, row 3; Core count 24, conductor specifications 2×2.5; Short-term]1000 N
Bend Radius [GDTA; Parameter image 2, row 3; Core count 24, conductor specifications 2×2.5; Static; D is the optical-cable diameter]10D
Bend Radius [GDTA; Parameter image 2, row 3; Core count 24, conductor specifications 2×2.5; Dynamic; D is the optical-cable diameter]20D
Fiber Count [GDTA; Parameter image 2, row 4; Core count 24, conductor specifications 2×4.0]24
Conductor Specifications [GDTA; Parameter image 2, row 4; Core count 24, conductor specifications 2×4.0]2×4.0
Structure [GDTA; Parameter image 2, row 4; Core count 24, conductor specifications 2×4.0]1+4
Outer Diameter [GDTA; Parameter image 2, row 4; Core count 24, conductor specifications 2×4.0]14.9 mm
Weight [GDTA; Parameter image 2, row 4; Core count 24, conductor specifications 2×4.0]298 kg/km
Tensile Force [GDTA; Parameter image 2, row 4; Core count 24, conductor specifications 2×4.0; Long-term]600 N
Tensile Force [GDTA; Parameter image 2, row 4; Core count 24, conductor specifications 2×4.0; Short-term]1500 N
Crush Force [GDTA; Parameter image 2, row 4; Core count 24, conductor specifications 2×4.0; Long-term]300 N
Crush Force [GDTA; Parameter image 2, row 4; Core count 24, conductor specifications 2×4.0; Short-term]1000 N
Bend Radius [GDTA; Parameter image 2, row 4; Core count 24, conductor specifications 2×4.0; Static; D is the optical-cable diameter]10D
Bend Radius [GDTA; Parameter image 2, row 4; Core count 24, conductor specifications 2×4.0; Dynamic; D is the optical-cable diameter]20D
Fiber Count [GDTA; Parameter image 2, row 5; Core count 24, conductor specifications 2×6.0]24
Conductor Specifications [GDTA; Parameter image 2, row 5; Core count 24, conductor specifications 2×6.0]2×6.0
Structure [GDTA; Parameter image 2, row 5; Core count 24, conductor specifications 2×6.0]1+4
Outer Diameter [GDTA; Parameter image 2, row 5; Core count 24, conductor specifications 2×6.0]16.3 mm
Weight [GDTA; Parameter image 2, row 5; Core count 24, conductor specifications 2×6.0]377 kg/km
Tensile Force [GDTA; Parameter image 2, row 5; Core count 24, conductor specifications 2×6.0; Long-term]600 N
Tensile Force [GDTA; Parameter image 2, row 5; Core count 24, conductor specifications 2×6.0; Short-term]1500 N
Crush Force [GDTA; Parameter image 2, row 5; Core count 24, conductor specifications 2×6.0; Long-term]300 N
Crush Force [GDTA; Parameter image 2, row 5; Core count 24, conductor specifications 2×6.0; Short-term]1000 N
Bend Radius [GDTA; Parameter image 2, row 5; Core count 24, conductor specifications 2×6.0; Static; D is the optical-cable diameter]10D
Bend Radius [GDTA; Parameter image 2, row 5; Core count 24, conductor specifications 2×6.0; Dynamic; D is the optical-cable diameter]20D
Fiber Count [GDTA; Parameter image 2, row 6; Core count 24, conductor specifications 2×10.0]24
Conductor Specifications [GDTA; Parameter image 2, row 6; Core count 24, conductor specifications 2×10.0]2×10.0
Structure [GDTA; Parameter image 2, row 6; Core count 24, conductor specifications 2×10.0]1+4
Outer Diameter [GDTA; Parameter image 2, row 6; Core count 24, conductor specifications 2×10.0]19.6 mm
Weight [GDTA; Parameter image 2, row 6; Core count 24, conductor specifications 2×10.0]574 kg/km
Tensile Force [GDTA; Parameter image 2, row 6; Core count 24, conductor specifications 2×10.0; Long-term]600 N
Tensile Force [GDTA; Parameter image 2, row 6; Core count 24, conductor specifications 2×10.0; Short-term]1500 N
Crush Force [GDTA; Parameter image 2, row 6; Core count 24, conductor specifications 2×10.0; Long-term]300 N
Crush Force [GDTA; Parameter image 2, row 6; Core count 24, conductor specifications 2×10.0; Short-term]1000 N
Bend Radius [GDTA; Parameter image 2, row 6; Core count 24, conductor specifications 2×10.0; Static; D is the optical-cable diameter]10D
Bend Radius [GDTA; Parameter image 2, row 6; Core count 24, conductor specifications 2×10.0; Dynamic; D is the optical-cable diameter]20D
Fiber Count [GDTA; Parameter image 2, row 7; Core count 24, conductor specifications 2×16.0]24
Conductor Specifications [GDTA; Parameter image 2, row 7; Core count 24, conductor specifications 2×16.0]2×16.0
Structure [GDTA; Parameter image 2, row 7; Core count 24, conductor specifications 2×16.0]1+4
Outer Diameter [GDTA; Parameter image 2, row 7; Core count 24, conductor specifications 2×16.0]22.2 mm
Weight [GDTA; Parameter image 2, row 7; Core count 24, conductor specifications 2×16.0]793 kg/km
Tensile Force [GDTA; Parameter image 2, row 7; Core count 24, conductor specifications 2×16.0; Long-term]600 N
Tensile Force [GDTA; Parameter image 2, row 7; Core count 24, conductor specifications 2×16.0; Short-term]1500 N
Crush Force [GDTA; Parameter image 2, row 7; Core count 24, conductor specifications 2×16.0; Long-term]300 N
Crush Force [GDTA; Parameter image 2, row 7; Core count 24, conductor specifications 2×16.0; Short-term]1000 N
Bend Radius [GDTA; Parameter image 2, row 7; Core count 24, conductor specifications 2×16.0; Static; D is the optical-cable diameter]10D
Bend Radius [GDTA; Parameter image 2, row 7; Core count 24, conductor specifications 2×16.0; Dynamic; D is the optical-cable diameter]20D

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Ho
Hongan
View Supplier →
Hong'an Group Co., Ltd., founded in 1985, is located in Weihai City, Shandong Province. The factory covers an area of 1 million square meters, with a building area of 400,000 square meters. Its main products include optical fiber preforms, optical fibers, optical cables, optical jumpers, data cables, communication cables, communication equipment, optical devices, etc. It is one of the backbone enterprises in China's optoelectronic communication cable industry. Products are sold well to mainstream domestic operators and exported to Europe, America, and countries and regions along the "Belt and Road", enjoying a wide reputation in domestic and international markets. The group company has a broad business layout, with multiple wholly-owned, controlled, and joint ventures such as Weihai Changhe Optical Technology, Weihai Weixin Optical Fiber Technology, Changhe Optical Cable, Hong'an Communication Cable, Hefei Bangnuo Technology, etc. At the same time, the group has strong R&D strength and has built a multi-level innovation platform system, including a national-level postdoctoral research workstation, a nationally accredited CNAS laboratory, as well as provincial-level enterprise technology centers and provincial-level engineering laboratories, and has multiple municipal-level R&D institutions covering engineering laboratories, engineering technology research centers, and industrial design centers. For a long time, the company has fully implemented the three major strategies of technological innovation, talent development, and export-oriented development, always adhering to science and technology leading enterprise development, through the introduction of advanced production equipment to digest, absorb, and then innovate and create, greatly enhancing independent innovation capability, and continuously providing high-quality and stable products and services to more than 100 countries and regions.

Request a Quote

Our team responds within 24–48 hours
GDTA hybrid optical/electrical cable
Hongan · Fiber Cables & Bundles
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →