Lambda microscopic hyperspectral imaging fits most commercial microscopes. An area detector, drive supply, motion control and acquisition modules are integrated without a motorized stage, greatly reducing size/weight for simple microscope operation. Applications include tumor-cell identification, hemorrhagic-polyps/fleshy-white-patch identification, lymphocytic-leukemia screening, cytoplasm/nucleus discrimination and cell counting. Darkfield excludes unrelated light from the objective, revealing clear outlines on a dark background; particles as small as 4~200nm can be seen, with resolution stated as 50 times ordinary brightfield. Hyperspectral microscopy identifies particle types. The figure uses VNIR imaging of mouse lung after a single low (18 pg) or high (162 pg) intratracheal titanium-dioxide nanoparticle dose to locate retained particles. Darkfield hyperspectral images show white-inclusion aggregates in the middle image; hyperspectral maps show red dots/aggregates below. Different eyepiece magnifications produce high-spatial-resolution OLED emission images, combining images/spectra to inspect uniformity/stability. Noncontact, nondamaging, rapid microregion measurement operates at room temperature or inline, obtaining whole-wafer PL Mapping for substrate/epilayer composition ratios, defects and other microregional uniformity. It identifies wafer materials and changes in emission-center concentration at fine scales. Compared with confocal imaging for perovskite inhomogeneity, advantages include single full-field imaging, uniform excitation intensity across the PL field and quantitative spectral intensity. Semiconductor uses include emission uniformity, defect analysis and spatial LED-chip temperature distributions. Additional cases from readable page text: rapid hyperspectral identification of laryngeal mucosal hemorrhagic polyps/fleshy-white-patch regions, shown red; tumor/abnormal-cell spread at 20-times eyepiece magnification; rapid nucleus/cytoplasm/other-material discrimination; counting by cell centroids, total 402; darkfield nanoparticle-exposed tissue, upper image; OLED emission at 20X,50X,100X; images/spectra of boron-implanted, aluminum-implanted and special unimplanted wafers; perovskite PL data: (a)/(b) are monochromatic images at 625nm/750nm, (c) spectra from different positions in Figure 1, (d) regional PL spectral-shift imaging; hyperspectral inversion of temperatures on different LED source panels.
Overview
Specifications
| Parameter | Value |
|---|---|
| Spectral Range | 420~1000nm |
| Spectral Resolution | 10nm |
| Number of Spectral Channels | >100 |
| Standard Lens-Focal Length [Other optional focal lengths: 16mm, 35mm, 50mm; inquire about other options] | 25 (other focal lengths optional) |
| Standard Lens-Working Distance | 150-∞ |
| Standard Lens-Field of View | 23° |
| Detector | 2048×2048 CMOS |
| Pixel Count (Spatial Dimension × Scan Dimension) | 1600×1200(1X); 800×600(2X) |
| Pixel Size | 6.5 μm × 6.5 μm |
| Digital Output | 12bit |
| Frame Count | 10μs-10s |
| Built-in Computer Interface | USB3.0+HDMI |
| Lens Mount | C-Mount |
| System Power Supply [DC] | DC 16.8V |
| Built-in Microprocessor | I7 processor, 16G RAM, 256G SSD |
| Built-in Battery | 65Wh |
| System Power Consumption | 60W |