Scientific-grade ICCD Camera
This product uses advanced picosecond-gated image-intensification technology. Integrating a high-quantum-efficiency image intensifier with a high-performance CCD sensor provides fast image acquisition and sensitivity down to single photons. In a picosecond ICCD camera, the front optical system processes images of ultrafast phenomena and delivers them to the ICCD image intensifier. A high-precision pulse generator produces a sequence of gating pulses that open the intensifier in turn, allowing the intensified image information to enter the image sensor for storage and further processing. The camera offers excellent temporal and spatial resolution and good stability.
Request a Quote
Download Datasheet
Overview
This product uses advanced picosecond-gated image-intensification technology. Integrating a high-quantum-efficiency image intensifier with a high-performance CCD sensor provides fast image acquisition and sensitivity down to single photons. In a picosecond ICCD camera, the front optical system processes images of ultrafast phenomena and delivers them to the ICCD image intensifier. A high-precision pulse generator produces a sequence of gating pulses that open the intensifier in turn, allowing the intensified image information to enter the image sensor for storage and further processing. The camera offers excellent temporal and spatial resolution and good stability.
Specifications
| Parameter | Value |
|---|---|
| CCD Camera - Resolution | 2688*2200 5.9Mpix |
| CCD Camera - Pixel size | 4.54 um × 4.54 um |
| CCD camera - Sensor active area | 12.5*10mm Diagonal 16mm |
| CCD camera - Acquisition frame rate | 6.9fps full frame, 10.9fps binned 2*2 |
| CCD Camera - Pixel Depth | 14bits |
| CCD Camera - Exposure Time | 25us - 60min |
| CCD camera - Full well capacity | >9ke- |
| CCD camera - Readout noise | 5.7e- |
| CCD Camera - Dark Current [@-20℃] | 0.00017e-/pix/s @-20℃ |
| CCD Camera - Cooling method | Multistage TEC cooling |
| Image intensifier - Photocathode | GaAs / S25 / Hi-QE Blue |
| Image intensifier - Equivalent background illuminance [Photocathode :GaAs] | <0.25μlx |
| Image intensifier - Equivalent background illuminance [Photocathode :S25] | <0.25μlx |
| Image intensifier - Equivalent background illuminance [Photocathode :Hi-QE Blue] | <0.05ulx |
| Image intensifier - Spectral range [Photocathode :GaAs] | 500-900nm |
| Image intensifier - Spectral range [Photocathode :S25] | 400-900nm |
| Image intensifier - Spectral range [Photocathode :Hi-QE Blue] | 185nm-700nm |
| Image intensifier - Effective aperture [Photocathode :GaAs / S25 / Hi-QE Blue] | ϕ18mm |
| Image intensifier - Coupling ratio [Photocathode :GaAs / S25 / Hi-QE Blue] | 1:1/1:1.33 |
| Image intensifier - Gain [Photocathode :GaAs / S25 / Hi-QE Blue / Single-layer MCP] | >1000( Single-layer MCP ) |
| Image intensifier - Gain [Photocathode :GaAs / S25 / Hi-QE Blue / Double layer MCP] | >100000( Double layer MCP) |
| Image intensifier - Resolution [Photocathode :GaAs / S25 / Hi-QE Blue / Single-layer MCP] | 55-65lp/mm( Single-layer MCP ) |
| Image intensifier - Resolution [Photocathode :GaAs / S25 / Hi-QE Blue / Double layer MCP] | 25-35lp/mm( Double layer MCP) |
| Image intensifier - Phosphor screen [Photocathode :GaAs / S25 / Hi-QE Blue] | P43 |
| Image intensifier - Minimum optical gate width [Photocathode :GaAs / S25 / Hi-QE Blue] | 3ns- Continuous adjustable (3000 Model ) / 500ps(500 Model ) |
| Image intensifier - Repetition frequency [Photocathode :GaAs / S25 / Hi-QE Blue] | 300KHz / 350KHz |
| Synchronization/gating circuit - Operating mode | Continuous high level:set the channel to continuously output a 4V DC signal; internal trigger:set the channel to output a 0.02Hz-200KHz pulse signal with adjustable pulse width and delay; external trigger:for an external trigger input of 0.1Hz-300KHz, output a pulse signal at the same frequency with adjustable pulse width and delay |
| Synchronization/gating circuit - Synchronization interface | External trigger Input *1; Synchronous output *2 |
| Synchronization/gating circuit - External trigger input specifications | Trigger threshold: 0.1-5V adjustable; input impedance: 50Ω/10KΩ configurable; minimum trigger width: 3ns |
| Synchronization/gating circuit - Synchronization signal output | 2 output channels: output amplitude 4V, impedance 50 ohms; channel signal parameters: pulse width 3ns-10s, minimum adjustment resolution 3ns; channel delay 0-10s, minimum resolution 10ps |
| Synchronization/gating circuit - External trigger delay | External trigger Input :<70ns |
| Synchronization/gating circuit - Internal trigger frequency | 0-300KHz |
| Synchronization/gating circuit - Timing jitter | Interchannel jitter <35ps |
Applications
Combustion/plasma diagnostics; fluorescence lifetime; gated Raman spectroscopy; gated imaging; low-light imaging; laser-induced fluorescence/breakdown spectroscopy. Suitable for academic research at institutes, universities and research organizations. This product enhances weak optical signals, extends the spectral detection range from ultraviolet to near infrared and provides picosecond exposure times. Applications include research on combustion, electrical discharges, biomechanics, fluorescence-lifetime detection, detonation tests and plasma diagnostics using high-speed and scientific cameras.
Key Features
Optical gating as short as 500ps effectively suppresses noise interference. Typical optical gate width of 3ns for low-cost gated imaging. High-precision timing synchronization on the 10ps scale supports precise three-dimensional temporal/spatial sequence slicing. High-gain optical-signal amplification with single-photon-level detection sensitivity. Advanced noise suppression and image processing. Replaceable optical interface.
Datasheet
Product Datasheet
PDF
Supplier Information
Dongguan Zhongke Atom Precision Manufacturing Technology Co., Ltd. is a high-tech enterprise focusing on photoelectric detection and laser sensing technologies. It is dedicated to the R&D and production of optical sensors such as super second-generation, third-generation, and ultrafast image intensifiers, photomultiplier tubes, electron/ion detection devices, as well as digital cameras like intensified cameras and low-light cameras. It also provides laser sensors including laser wind radar, ceilometer, TOF lidar, and instruments such as time-resolved Raman spectrometers and time-gated imagers. Products are widely used in low-light night vision, laser 3D surveying, industrial inspection, and scientific research. The company is located in Songshan Lake, Dongguan, with comprehensive OEM and customized solution capabilities.
Contact Us
Loading...
GetExperimental Plan
Name
Phone
+86
Organization
Use Case

Global Photonics Products
Database Platform
Database Platform
With 16 years of experience, we provide high-quality products and services to universities, research institutes, and industry.
50+ Detailed Categories · 3,000+ Global Brands · 100,000+ Photonics Products
1 Million+
In-depth analysis of professional academic resources in photonics
300,000
ProductsDatasheets Available Free
We will keep your personal information strictly confidential.
Product Quote
+86
* Select the quoting party:
By submitting, you agree to the User Service Agreement and Privacy Policy