(N+1)x1 Backward High Power Pump and Signal Combiner

(N+1)x1 Backward High Power Pump and Signal Combiner

Supplier
Sicart
Category
Pump Combiners
Origin
China

The High Power Pump and Signal Combiner (HPPC) is designed for combining pump laser and signal laser into the main double cladding fiber. The HPPC can be applied in backward or double-end pumping schemes.

Specification Snapshot
Pump Wavelength
min:800 nm;typical:915 nm;max:1000 nm
Storage Temperature
min:-40 °C;max:+85 °C
Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

The High Power Pump and Signal Combiner (HPPC) is designed for combining pump laser and signal laser into the main double cladding fiber. The HPPC can be applied in backward or double-end pumping schemes.

Specifications

ParameterValue
Signal Wavelengthmin:1000 nm;typical:1060 nm;max:1100 nm
Pump Wavelengthmin:800 nm;typical:915 nm;max:1000 nm
Polarization [PM Customizable]Random
Operation RegimeCW
Fiber Length [Default]typical:1.5 m
Operating Temperature Rangemin:0 °C;max:+70 °C
Storage Temperaturemin:-40 °C;max:+85 °C
Cooling MethodBottom conduction cooling
Power Handling [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 105/125 106.5/125 135/155; Signal Fiber: X/250DCF X/400 DCF 34/460/530; Output Fiber: Y/130DCF Y/250DCF; Notes: X,Y=14, 20, 25, 30 X≤Y]300W/leg
Pump Efficiency [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 105/125 106.5/125 135/155; Signal Fiber: X/250DCF X/400 DCF 34/460/530; Output Fiber: Y/130DCF Y/250DCF; Notes: X,Y=14, 20, 25, 30 X≤Y]97%
Signal Fiber [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 105/125 106.5/125 135/155; Signal Fiber: X/250DCF X/400 DCF 34/460/530; Output Fiber: Y/130DCF Y/250DCF; Notes: X,Y=14, 20, 25, 30 X≤Y]2kW
Signal IL [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 105/125 106.5/125 135/155; Signal Fiber: X/250DCF X/400 DCF 34/460/530; Output Fiber: Y/130DCF Y/250DCF; Notes: X,Y=14, 20, 25, 30 X≤Y]0.2dB
Power Handling [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 105/125 106.5/125 135/155; Signal Fiber: X/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: X,Y=20, 25, 30 X≤Y]300W/leg
Pump Efficiency [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 105/125 106.5/125 135/155; Signal Fiber: X/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: X,Y=20, 25, 30 X≤Y]97%
Signal Fiber [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 105/125 106.5/125 135/155; Signal Fiber: X/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: X,Y=20, 25, 30 X≤Y]2kW
Signal IL [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 105/125 106.5/125 135/155; Signal Fiber: X/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: X,Y=20, 25, 30 X≤Y]0.2dB
Power Handling [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 200/220 220/242 225/240; Signal Fiber: 20/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: Y=20, 25, 30]800W/leg
Pump Efficiency [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 200/220 220/242 225/240; Signal Fiber: 20/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: Y=20, 25, 30]97%
Signal Fiber [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 200/220 220/242 225/240; Signal Fiber: 20/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: Y=20, 25, 30]3kW
Signal IL [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 200/220 220/242 225/240; Signal Fiber: 20/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: Y=20, 25, 30]0.2dB
Power Handling [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 200/220 220/242 225/240; Signal Fiber: 25/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: Y=25, 30]800W/leg
Pump Efficiency [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 200/220 220/242 225/240; Signal Fiber: 25/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: Y=25, 30]97%
Signal Fiber [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 200/220 220/242 225/240; Signal Fiber: 25/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: Y=25, 30]4kW
Signal IL [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 200/220 220/242 225/240; Signal Fiber: 25/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: Y=25, 30]0.2dB
Power Handling [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 200/220 220/242 225/240; Signal Fiber: 30/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: Y=30]800W/leg
Pump Efficiency [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 200/220 220/242 225/240; Signal Fiber: 30/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: Y=30]97%
Signal Fiber [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 200/220 220/242 225/240; Signal Fiber: 30/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: Y=30]5kW
Signal IL [Config.: (6+1)×1 (9+1)×1 (12+1)×1; Pump Fiber: 200/220 220/242 225/240; Signal Fiber: 30/400DCF X/600DCF 34/460/530; Output Fiber: Y/250DCF Y/400DCF; Notes: Y=30]0.2dB
Power Handling [Config.: (18+1)×1 SCF, 0.08NA; Pump Fiber: 105/125 106.5/125; Signal Fiber: X/250DCF X/600DCF 34/460/530; Output Fiber: Y/130DCF; Notes: X,Y=20, 25, 30 X≤Y]200W/leg
Pump Efficiency [Config.: (18+1)×1 SCF, 0.08NA; Pump Fiber: 105/125 106.5/125; Signal Fiber: X/250DCF X/600DCF 34/460/530; Output Fiber: Y/130DCF; Notes: X,Y=20, 25, 30 X≤Y]96%
Signal Fiber [Config.: (18+1)×1 SCF, 0.08NA; Pump Fiber: 105/125 106.5/125; Signal Fiber: X/250DCF X/600DCF 34/460/530; Output Fiber: Y/130DCF; Notes: X,Y=20, 25, 30 X≤Y]3kW
Signal IL [Config.: (18+1)×1 SCF, 0.08NA; Pump Fiber: 105/125 106.5/125; Signal Fiber: X/250DCF X/600DCF 34/460/530; Output Fiber: Y/130DCF; Notes: X,Y=20, 25, 30 X≤Y]0.2dB
Power Handling [Config.: (18+1)×1 SCF, 0.08NA; Pump Fiber: 105/125 106.5/125; Signal Fiber: X/400DCF X/600DCF 34/460/530; Output Fiber: Y/130DCF Y/250DCF; Notes: X,Y=20, 25, 30 X≤Y]200W/leg
Pump Efficiency [Config.: (18+1)×1 SCF, 0.08NA; Pump Fiber: 105/125 106.5/125; Signal Fiber: X/400DCF X/600DCF 34/460/530; Output Fiber: Y/130DCF Y/250DCF; Notes: X,Y=20, 25, 30 X≤Y]96%
Signal Fiber [Config.: (18+1)×1 SCF, 0.08NA; Pump Fiber: 105/125 106.5/125; Signal Fiber: X/400DCF X/600DCF 34/460/530; Output Fiber: Y/130DCF Y/250DCF; Notes: X,Y=20, 25, 30 X≤Y]3kW
Signal IL [Config.: (18+1)×1 SCF, 0.08NA; Pump Fiber: 105/125 106.5/125; Signal Fiber: X/400DCF X/600DCF 34/460/530; Output Fiber: Y/130DCF Y/250DCF; Notes: X,Y=20, 25, 30 X≤Y]0.2dB
Power Handling [Config.: (18+1)×1 SCF, 0.08NA; Pump Fiber: 135/155; Signal Fiber: X/400DCF X/600DCF 34/460/530; Output Fiber: Y/130DCF Y/250DCF; Notes: X,Y=20, 25, 30 X≤Y]200W/leg
Pump Efficiency [Config.: (18+1)×1 SCF, 0.08NA; Pump Fiber: 135/155; Signal Fiber: X/400DCF X/600DCF 34/460/530; Output Fiber: Y/130DCF Y/250DCF; Notes: X,Y=20, 25, 30 X≤Y]96%
Signal Fiber [Config.: (18+1)×1 SCF, 0.08NA; Pump Fiber: 135/155; Signal Fiber: X/400DCF X/600DCF 34/460/530; Output Fiber: Y/130DCF Y/250DCF; Notes: X,Y=20, 25, 30 X≤Y]5kW
Signal IL [Config.: (18+1)×1 SCF, 0.08NA; Pump Fiber: 135/155; Signal Fiber: X/400DCF X/600DCF 34/460/530; Output Fiber: Y/130DCF Y/250DCF; Notes: X,Y=20, 25, 30 X≤Y]0.2dB

Datasheet

Product Datasheet
PDF
Download

Supplier Information

Si
Sicart
View Supplier →
SiCART, established in 2019, is a National High-Tech Enterprise dedicated to the research, development, manufacturing, and sales of fiber optic components and visible laser technologies. Our products are widely deployed across a range of cutting-edge applications, including fiber optic sensing, industrial laser systems, biophotonics, optical communications, data centers, industrial inspection, and autonomous driving. Backed by years of accumulated expertise and a highly skilled R&D team, SiCART has built a robust and well-established production and quality management system. Our unwavering commitment to superior product quality and rapid delivery has earned us the trust and long-term collaboration of clients worldwide. SiCART is ISO 9001 certified and holds a number of invention and utility model patents, providing a strong foundation for continued innovation and sustainable growth.

Request a Quote

Our team responds within 24–48 hours
(N+1)x1 Backward High Power Pump and Signal Combiner
Sicart · Pump Combiners
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →