Outdoor Self-Supporting Power-System Optical Cable ADSS

Outdoor Self-Supporting Power-System Optical Cable ADSS

Supplier
Xkkb
Category
Fiber Cables & Bundles
Origin
China

The ADSS cable uses stranded loose tubes containing 250um fibers and water-blocking compound. Tubes and filler cords are stranded around a nonmetallic FRP strength member into a compact core, with water-blocking grease in the gaps. A polyethylene inner sheath (FE) is extruded around the core, followed by reinforcing aramid yarn and an outer polyethylene (PE) or anti-tracking (AT) sheath.

Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

The ADSS cable uses stranded loose tubes containing 250um fibers and water-blocking compound. Tubes and filler cords are stranded around a nonmetallic FRP strength member into a compact core, with water-blocking grease in the gaps. A polyethylene inner sheath (FE) is extruded around the core, followed by reinforcing aramid yarn and an outer polyethylene (PE) or anti-tracking (AT) sheath.

Specifications

ParameterValue
Reference Outer Diameter12.5 mm
Reference weight [Reference Outer Diameter mm: 12.5; PE]125 kg/km
Reference weight [Reference Outer Diameter mm: 12.5; AT]138 kg/km
Daily ****** Working Tension [Reference Outer Diameter mm: 12.5]1.5 KN
****** Allowable Working Tension [Reference Outer Diameter mm: 12.5]4 KN
Breaking Strength [Reference Outer Diameter mm: 12.5]10 KN
Tensile Member Cross-Sectional Area [Reference Outer Diameter mm: 12.5]4.6 mm²
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 12.5; Corresponding Weather Conditions: A]160 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 12.5; Corresponding Weather Conditions: B]100 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 12.5; Corresponding Weather Conditions: C]140 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 12.5; Corresponding Weather Conditions: D]100 M
Reference Outer Diameter13.0 mm
Reference weight [Reference Outer Diameter mm: 13.0; PE]132 kg/km
Reference weight [Reference Outer Diameter mm: 13.0; AT]142 kg/km
Daily ****** Working Tension [Reference Outer Diameter mm: 13.0]2.25 KN
****** Allowable Working Tension [Reference Outer Diameter mm: 13.0]6 KN
Breaking Strength [Reference Outer Diameter mm: 13.0]15 KN
Tensile Member Cross-Sectional Area [Reference Outer Diameter mm: 13.0]7.6 mm²
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.0; Corresponding Weather Conditions: A]230 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.0; Corresponding Weather Conditions: B]150 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.0; Corresponding Weather Conditions: C]200 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.0; Corresponding Weather Conditions: D]150 M
Reference Outer Diameter13.3 mm
Reference weight [Reference Outer Diameter mm: 13.3; PE]137 kg/km
Reference weight [Reference Outer Diameter mm: 13.3; AT]148 kg/km
Daily ****** Working Tension [Reference Outer Diameter mm: 13.3]3.0 KN
****** Allowable Working Tension [Reference Outer Diameter mm: 13.3]8 KN
Breaking Strength [Reference Outer Diameter mm: 13.3]20 KN
Tensile Member Cross-Sectional Area [Reference Outer Diameter mm: 13.3]10.35 mm²
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.3; Corresponding Weather Conditions: A]300 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.3; Corresponding Weather Conditions: B]200 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.3; Corresponding Weather Conditions: C]290 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.3; Corresponding Weather Conditions: D]200 M
Reference Outer Diameter13.6 mm
Reference weight [Reference Outer Diameter mm: 13.6; PE]145 kg/km
Reference weight [Reference Outer Diameter mm: 13.6; AT]156 kg/km
Daily ****** Working Tension [Reference Outer Diameter mm: 13.6]3.6 KN
****** Allowable Working Tension [Reference Outer Diameter mm: 13.6]10 KN
Breaking Strength [Reference Outer Diameter mm: 13.6]24 KN
Tensile Member Cross-Sectional Area [Reference Outer Diameter mm: 13.6]13.8 mm²
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.6; Corresponding Weather Conditions: A]370 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.6; Corresponding Weather Conditions: B]250 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.6; Corresponding Weather Conditions: C]350 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.6; Corresponding Weather Conditions: D]250 M
Reference Outer Diameter13.8 mm
Reference weight [Reference Outer Diameter mm: 13.8; PE]147 kg/km
Reference weight [Reference Outer Diameter mm: 13.8; AT]159 kg/km
Daily ****** Working Tension [Reference Outer Diameter mm: 13.8]4.5 KN
****** Allowable Working Tension [Reference Outer Diameter mm: 13.8]12 KN
Breaking Strength [Reference Outer Diameter mm: 13.8]30 KN
Tensile Member Cross-Sectional Area [Reference Outer Diameter mm: 13.8]14.3 mm²
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.8; Corresponding Weather Conditions: A]420 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.8; Corresponding Weather Conditions: B]280 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.8; Corresponding Weather Conditions: C]400 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 13.8; Corresponding Weather Conditions: D]280 M
Reference Outer Diameter14.5 mm
Reference weight [Reference Outer Diameter mm: 14.5; PE]164 kg/km
Reference weight [Reference Outer Diameter mm: 14.5; AT]177 kg/km
Daily ****** Working Tension [Reference Outer Diameter mm: 14.5]5.4 KN
****** Allowable Working Tension [Reference Outer Diameter mm: 14.5]15 KN
Breaking Strength [Reference Outer Diameter mm: 14.5]36 KN
Tensile Member Cross-Sectional Area [Reference Outer Diameter mm: 14.5]18.4 mm²
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 14.5; Corresponding Weather Conditions: A]480 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 14.5; Corresponding Weather Conditions: B]320 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 14.5; Corresponding Weather Conditions: C]460 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 14.5; Corresponding Weather Conditions: D]320 M
Reference Outer Diameter14.9 mm
Reference weight [Reference Outer Diameter mm: 14.9; PE]171 kg/km
Reference weight [Reference Outer Diameter mm: 14.9; AT]185 kg/km
Daily ****** Working Tension [Reference Outer Diameter mm: 14.9]6.75 KN
****** Allowable Working Tension [Reference Outer Diameter mm: 14.9]18 KN
Breaking Strength [Reference Outer Diameter mm: 14.9]45 KN
Tensile Member Cross-Sectional Area [Reference Outer Diameter mm: 14.9]22.0 mm²
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 14.9; Corresponding Weather Conditions: A]570 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 14.9; Corresponding Weather Conditions: B]380 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 14.9; Corresponding Weather Conditions: C]550 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 14.9; Corresponding Weather Conditions: D]380 M
Reference Outer Diameter15.1 mm
Reference weight [Reference Outer Diameter mm: 15.1; PE]179 kg/km
Reference weight [Reference Outer Diameter mm: 15.1; AT]193 kg/km
Daily ****** Working Tension [Reference Outer Diameter mm: 15.1]7.95 KN
****** Allowable Working Tension [Reference Outer Diameter mm: 15.1]22 KN
Breaking Strength [Reference Outer Diameter mm: 15.1]53 KN
Tensile Member Cross-Sectional Area [Reference Outer Diameter mm: 15.1]26.4 mm²
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 15.1; Corresponding Weather Conditions: A]670 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 15.1; Corresponding Weather Conditions: B]460 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 15.1; Corresponding Weather Conditions: C]650 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 15.1; Corresponding Weather Conditions: D]480 M
Reference Outer Diameter15.5 mm
Reference weight [Reference Outer Diameter mm: 15.5; PE]190 kg/km
Reference weight [Reference Outer Diameter mm: 15.5; AT]204 kg/km
Daily ****** Working Tension [Reference Outer Diameter mm: 15.5]9.0 KN
****** Allowable Working Tension [Reference Outer Diameter mm: 15.5]26 KN
Breaking Strength [Reference Outer Diameter mm: 15.5]60 KN
Tensile Member Cross-Sectional Area [Reference Outer Diameter mm: 15.5]32.2 mm²
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 15.5; Corresponding Weather Conditions: A]750 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 15.5; Corresponding Weather Conditions: B]530 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 15.5; Corresponding Weather Conditions: C]750 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 15.5; Corresponding Weather Conditions: D]510 M
Reference Outer Diameter15.6 mm
Reference weight [Reference Outer Diameter mm: 15.6; PE]194 kg/km
Reference weight [Reference Outer Diameter mm: 15.6; AT]208 kg/km
Daily ****** Working Tension [Reference Outer Diameter mm: 15.6]10.5 KN
****** Allowable Working Tension [Reference Outer Diameter mm: 15.6]28 KN
Breaking Strength [Reference Outer Diameter mm: 15.6]70 KN
Tensile Member Cross-Sectional Area [Reference Outer Diameter mm: 15.6]33.0 mm²
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 15.6; Corresponding Weather Conditions: A]800 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 15.6; Corresponding Weather Conditions: B]560 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 15.6; Corresponding Weather Conditions: C]800 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 15.6; Corresponding Weather Conditions: D]560 M
Reference Outer Diameter16.3 mm
Reference weight [Reference Outer Diameter mm: 16.3; PE]211 kg/km
Reference weight [Reference Outer Diameter mm: 16.3; AT]226 kg/km
Daily ****** Working Tension [Reference Outer Diameter mm: 16.3]12.75 KN
****** Allowable Working Tension [Reference Outer Diameter mm: 16.3]34 KN
Breaking Strength [Reference Outer Diameter mm: 16.3]85 KN
Tensile Member Cross-Sectional Area [Reference Outer Diameter mm: 16.3]40.0 mm²
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 16.3; Corresponding Weather Conditions: A]880 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 16.3; Corresponding Weather Conditions: B]650 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 16.3; Corresponding Weather Conditions: C]880 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 16.3; Corresponding Weather Conditions: D]650 M
Reference Outer Diameter16.8 mm
Reference weight [Reference Outer Diameter mm: 16.8; PE]226 kg/km
Reference weight [Reference Outer Diameter mm: 16.8; AT]242 kg/km
Daily ****** Working Tension [Reference Outer Diameter mm: 16.8]15.45 KN
****** Allowable Working Tension [Reference Outer Diameter mm: 16.8]41 KN
Breaking Strength [Reference Outer Diameter mm: 16.8]103 KN
Tensile Member Cross-Sectional Area [Reference Outer Diameter mm: 16.8]48.0 mm²
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 16.8; Corresponding Weather Conditions: A]1000 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 16.8; Corresponding Weather Conditions: B]750 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 16.8; Corresponding Weather Conditions: C]1000 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 16.8; Corresponding Weather Conditions: D]760 M
Reference Outer Diameter17.2 mm
Reference weight [Reference Outer Diameter mm: 17.2; PE]236 kg/km
Reference weight [Reference Outer Diameter mm: 17.2; AT]253 kg/km
Daily ****** Working Tension [Reference Outer Diameter mm: 17.2]16.2 KN
****** Allowable Working Tension [Reference Outer Diameter mm: 17.2]45 KN
Breaking Strength [Reference Outer Diameter mm: 17.2]108 KN
Tensile Member Cross-Sectional Area [Reference Outer Diameter mm: 17.2]51.0 mm²
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 17.2; Corresponding Weather Conditions: A]1100 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 17.2; Corresponding Weather Conditions: B]800 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 17.2; Corresponding Weather Conditions: C]1100 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 17.2; Corresponding Weather Conditions: D]830 M
Reference Outer Diameter17.9 mm
Reference weight [Reference Outer Diameter mm: 17.9; PE]249 kg/km
Reference weight [Reference Outer Diameter mm: 17.9; AT]266 kg/km
Daily ****** Working Tension [Reference Outer Diameter mm: 17.9]18.0 KN
****** Allowable Working Tension [Reference Outer Diameter mm: 17.9]50 KN
Breaking Strength [Reference Outer Diameter mm: 17.9]120 KN
Tensile Member Cross-Sectional Area [Reference Outer Diameter mm: 17.9]58.8 mm²
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 17.9; Corresponding Weather Conditions: A]1180 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 17.9; Corresponding Weather Conditions: B]880 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 17.9; Corresponding Weather Conditions: C]1180 M
For span M under the corresponding meteorological conditions [Reference Outer Diameter mm: 17.9; Corresponding Weather Conditions: D]900 M
Attenuation [G652; 1310 nm]≤0.36 dB/km
Attenuation [G655; 1310 nm]≤0.4 dB/km
Attenuation [G652; 1550 nm]≤0.22 dB/km
Attenuation [G655; 1550 nm]≤0.23 dB/km
Attenuation [50/125; 850 nm]≤3.0 dB/km
Attenuation [62.5/125; 850 nm]≤3.3 dB/km
Attenuation [50/125; 1300 nm]≤1.0 dB/km
Attenuation [62.5/125; 1300 nm]≤1.0 dB/km
Bandwidth (Grade A) [50/125; 850 nm; Grade A]≥500 MHz·km
Bandwidth (Grade A) [62.5/125; 850 nm; grade A]≥200 MHz·km
Bandwidth (Grade A) [50/125; 1300 nm; Grade A]≥1000 MHz·km
Bandwidth (Grade A) [62.5/125; 1300 nm; grade A]≥800 MHz·km
Numerical aperture [50/125; ±0.015]0.200±0.015NA
Numerical aperture [62.5/125; ±0.015]0.275±0.015NA
Cable Cutoff Wavelength [G652]≤ 1260 nm
Cable Cutoff Wavelength [G655]≤ 1450 nm
Product standardMeets IEEE1222-2004 Technology Standard IEC 60794-1 Standard
Storage/Operating Temperature-40~+70℃

Key Features

Can be installed without a power outage; AT jacket provides excellent tracking resistance; low weight and small cable diameter reduce ice and wind effects and loads on towers and supports; large spans exceeding 1000 meters; excellent tensile performance and temperature characteristics.

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Shandong Xinke Kaibang Communication Equipment Co., Ltd., located in Heze City, Shandong Province, is a high-tech enterprise dedicated to the professional research, development, and manufacturing of communication optical cables, communication cables, control cables, and photoelectric composite cables. Its products are widely used in communication operators, data cloud computing centers, rail transit, highways, mines, electric power, metallurgy, petrochemicals, medical care, water conservancy, ships, marine exploration, national defense, and nuclear industry, etc. The company was established in 2017 with a registered capital of 110 million yuan and covers an area of 58,000 square meters. Since its establishment, the company has adhered to Beijing as the brand center, Shandong as the production base, and Shenzhen as the foreign trade window, continuously innovating around customer needs and technological leadership to create value for customers. The company's main products include more than ten series such as halogen-free low-smoke series, flame-retardant series, fire-resistant series, intrinsically safe series, high-temperature resistant series, radiation-resistant series, etc., including communication optical cables, control cables, communication cables, railway signal cables, instrument signal cables, mining cables, marine cables, nuclear-grade cables, special-purpose cables, photoelectric composite cables, etc. In addition to complying with national standards (GB), Ministry of Coal standards (MT), International Electrotechnical Commission standards (IEC), British standards (BS), German standards (VDE), and other domestic and international standards, the company can also design and manufacture various non-standard, special requirements, and innovative optical cable products according to user requirements. The company has excellent production lines and inspection equipment, an independent product R&D center, and a testing laboratory. It always adheres to the business philosophy of market orientation, technology reliance, and quality survival, continuously developing new products. It has successfully developed temperature-sensing monitoring optical cables, vibration-sensing optical cables, radio frequency photoelectric composite cables, camera-specific composite cables, fire-resistant and radiation-resistant optical cables, mining quick connectors, mining photoelectric composite cables, etc.; and has obtained more than 60 utility model patents and multiple invention patents. The company has successively obtained quality system certification, environmental management system certification, occupational health system certification, energy management system certificate, information security management certificate, national industrial product license certificate, national compulsory product certification CCC certificate, and product manufacturing certificate from the General Armaments Department, etc.; products have obtained more than 40 "TLC certifications", "radio and television certifications", and more than 70 "mining product safety mark certificates". At the same time, it has won honors such as: Shandong Province "High-tech Enterprise", Shandong Province "Specialized and New Enterprise", Shandong Province "Technology-based Small and Medium-sized Enterprise", Shandong Province "Green Factory", Heze City "Specialized and New" Small and Medium-sized Enterprise, Heze City "Key Laboratory", Heze City "Technology Innovation Center", etc., and has been rated as a "contract-honoring and credit-worthy" unit for many consecutive years. The company upholds the quality policy of "technological innovation, honest service, continuous improvement, customer satisfaction" and has established a complete product quality control system. Full-process quality control and continuous improvement enhance product quality levels. Maintaining customer-centricity, with "integrity and diligence, technological innovation, respect for talent, and collaborative friendship" as the cultural core, to repay the love and support of users and friends from all walks of life.

Request a Quote

Our team responds within 24–48 hours
Outdoor Self-Supporting Power-System Optical Cable ADSS
Xkkb · Fiber Cables & Bundles
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →