Test and Measurements

Selected

Photonics Source provides 1728 products. Download datasheets, request quotes, and compare function, price, and availability.

  • IVS-2000 Optical Inspection

    IVS-2000

    China
    Category: Optical Inspection
    Manufacturer: Santec
    Measurement Range: 0-100μm Resolution: 0.1nm Measurement Speed: 10Hz Light Source Wavelength: 1310nm Light Source Type: Superluminescent Diode (SLD)
  • IVS-2000 Optical Inspection

    IVS-2000

    China
    Category: Optical Inspection
    Manufacturer: Santec
    Measurement Range: 0-200μm Resolution: 0.1nm Measurement Speed: Up to 10Hz Light Source Wavelength: 1310nm Light Source Type: Superluminescent Diode (SLD)
  • HSL High Speed Scanning Laser Optical Inspection

    HSL High Speed Scanning Laser

    China
    Category: Optical Inspection
    Manufacturer: Santec
    Scanning Speed: 100nm/ms Wavelength Range: 1260nm-1360nm Wavelength Accuracy: ±0.1nm Output Power: >10mW Fiber Type: SMF-28
  • OCTOPUS Robotic Interferometer Interferometers

    OCTOPUS Robotic Interferometer

    China
    Category: Interferometers
    Manufacturer: Santec
    Connectors inspected: MIL-DTL-38999 and other MIL style and harsh environment connectors Field of View: D=1.6mm Area covered: Y, X-axis motion: ±14mm Optical Resolution: 3.2μm Magnification: 300x
  • High Speed Swept Test System Fiber Test & Measurement

    High Speed Swept Test System

    China
    Manufacturer: Santec
    Wavelength Accuracy (typ.) (Absolute) Type A: ±12pm at 50nm/s, ±15pm at 100nm/s, ±17pm at 200nm/s Wavelength Accuracy (typ.) (Absolute) Type C: ±2.5pm at 50nm/s, ±3.5pm at 100nm/s, ±4.0pm at 200nm/s Wavelength Accuracy (typ.) (Absolute) Type P: ±1.0pm at 50nm/s, ±1.5pm at 100nm/s, ±2.0pm at 200nm/s Wavelength Accuracy (typ.) (Relative) Type A: ±12pm at 50nm/s, ±17pm at 100nm/s, ±20pm at 200nm/s Wavelength Accuracy (typ.) (Relative) Type C: ±3.0pm at 50nm/s, ±4.0pm at 100nm/s, ±4.3pm at 200nm/s
  • MAX-Quantum Interferometer Interferometers

    MAX-Quantum Interferometer

    China
    Category: Interferometers
    Manufacturer: Santec
    Repeatability C.F. ROC (MT12): 0.9% Repeatability C.F. ROC (SC/APC): 0.04% Fiber Height (MT12): 1.1nm Fiber Height (SC/APC): 0.4nm Angles (MT12): 0.01deg
  • XCS Expandable Chassis System Fiber Test & Measurement

    XCS Expandable Chassis System

    China
    Manufacturer: Santec
    Fiber Type (μm) FP Laser: 9/125 Fiber Type (μm) DFB: 9/125 Fiber Type (μm) LED: 50/125, 62.5/125 or 105/125 Nominal Wavelengths (nm) FP Laser: 1310/1490/1550/1625 Nominal Wavelengths (nm) DFB: 1271 to 1611
  • Full-band Tunable Laser System (Full-band TSL) Fiber Test & Measurement

    Full-band Tunable Laser System (Full-band TSL)

    China
    Manufacturer: Santec
    Wavelength Tuning Range (nm): 1240 to 1680 Full Tuning Range (nm): 440 Insertion Loss (dB): <3 (typ. 1.5) Insertion Loss Stability (dB): ±0.01 Repeatability (dB): ±0.01
  • XNS Expandable Network Server Fiber Test & Measurement

    XNS Expandable Network Server

    China
    Manufacturer: Santec
    Operating System: Windows 10 Hard Disk: RAID 5 mirrored RAM: 16GB Processor: Intel i7 or AMD EPYC Error Correcting: ECC RAM
  • WSL-110 Fiber Test & Measurement

    WSL-110

    China
    Manufacturer: Santec
    Wavelength Range C-band: 1527.60-1565.50nm Wavelength Range L-band: 1568.77-1608.76nm Frequency Range C-band: 191.50-196.25THz Frequency Range L-band: 186.35-191.1THz Channel Spacing: 25GHz (Any frequency is available)
  • VFH-100 Ribbon Visual Fault Locator Fiber Test & Measurement

    VFH-100 Ribbon Visual Fault Locator

    China
    Manufacturer: Santec
    Laser Sources: 12 Optical Interface: MTP/MPO/APC male or female Fiber Type: SMF28 Laser Wavelength: 635nm Output Power (Typ.): 0.50mW@9125
  • Cable Assembly Software Fiber Test & Measurement

    Cable Assembly Software

    China
    Manufacturer: Santec
    Operating System Requirements: Windows 10/11 (64-bit)
  • Cable Assembly Software Fiber Test & Measurement

    Cable Assembly Software

    China
    Manufacturer: Santec
    Operating System Requirements: Windows 10/11 (64-bit)
  • TSL-775 Fiber Test & Measurement

    TSL-775

    China
    Manufacturer: Santec
    Wavelength Tuning Range: 1480-1640nm, 1490-1630nm Wavelength Resolution: 0.1nm Absolute Accuracy: ±1.5pm Repeatability: ±0.5pm Stability: <±0.5 (24hours)
  • TSL-770 Fiber Test & Measurement

    TSL-770

    China
    Manufacturer: Santec
    Wavelength Tuning Range 480640: 1480-1640nm Wavelength Tuning Range 490630: 1490-1630nm Wavelength Setting Resolution: 0.1pm Wavelength Absolute Accuracy (Operating Temperature): ±1.5pm Wavelength Repeatability: ±0.5±0.2pm
  • TSL-580 Fiber Test & Measurement

    TSL-580

    China
    Manufacturer: Santec
    Wavelength Range: 1240-1380nm, 1355-1505nm, 1480-1640nm Wavelength Resolution: 0.1pm Wavelength Stability: ±1pm (typ.) Wavelength Repeatability: ±0.5pm Wavelength Accuracy: ±1.0pm at 50nm/s, ±1.5pm at 100nm/s, ±2.1pm at 200nm/s
  • TSL-570 Type U Fiber Test & Measurement

    TSL-570 Type U

    China
    Manufacturer: Santec
    Wavelength Range: 1270-1350nm Resolution: 0.1pm Wavelength Stability (typical value): ≤±1pm Wavelength Stability (Operating Temperature): ±2pm Wavelength Accuracy: ±0.5pm
  • TSL-570 Type H Fiber Test & Measurement

    TSL-570 Type H

    China
    Manufacturer: Santec
    Wavelength Tuning Range: 1260-1360/1500-1630nm Wavelength Setting Resolution: 0.1pm Wavelength Stability (typ.): ±1pm Absolute Wavelength Accuracy: ±1(typ.)pm Absolute Wavelength Accuracy (Operating temp.): ±2pm
  • TSL-570 High Performance Tunable Laser Fiber Test & Measurement

    TSL-570 High Performance Tunable Laser

    China
    Manufacturer: Santec
    Wavelength Tuning Range Type A: 1260-1360nm Wavelength Tuning Range Type C: 1355-1485nm Wavelength Tuning Range Type P: 1480-1640nm Wavelength Setting Resolution: 0.1pm Wavelength Stability (typ.) Type A: ≤±5pm
  • Swept Test System Fiber Test & Measurement

    Swept Test System

    China
    Manufacturer: Santec
    Absolute Wavelength Accuracy TypeA: ±12pm Absolute Wavelength Accuracy TypeC: ±2.5pm Absolute Wavelength Accuracy TypeP: ±1.0pm Relative Wavelength Accuracy TypeA: ±12pm Relative Wavelength Accuracy TypeC: ±3.0pm
AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →