iHR-Series Imaging Spectrometer iHR320
Specification Snapshot
Single-Pixel Size [Parameter Figure 03; Compatible with Synapse™, Symphony® and Syncerity™ Series CCDs; Separate Explanation of Compatible CCDs]
13.5~26 μm
Pixel Count [Parameter Image 03; Compatible CCD Range; Independent Description of Compatible CCDs]
512~2048
Cooling Method [Parameter Image 03 Compatible CCD Range; Independent Description of Compatible CCDs]
TE Cooling to Liquid Nitrogen Cooling
Detector Type [Parameter Image 03; Liquid-Nitrogen-Cooled SymphonyII Detector; Independent Description of Compatible CCDs]
Silicon, InGaAs and Extended InGaAs
Spectral Range [Parameter Image 03; Liquid-Nitrogen-Cooled SymphonyII Detector; Independent Description of Compatible CCDs]
200nm~2.2μm
Focal Length [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item]
320 mm
Request a Quote
Download Datasheet
Specifications
| Parameter | Value |
|---|---|
| Single-Pixel Size [Parameter Figure 03; Compatible with Synapse™, Symphony® and Syncerity™ Series CCDs; Separate Explanation of Compatible CCDs] | 13.5~26 μm |
| Pixel Count [Parameter Image 03; Compatible CCD Range; Independent Description of Compatible CCDs] | 512~2048 |
| Cooling Method [Parameter Image 03 Compatible CCD Range; Independent Description of Compatible CCDs] | TE Cooling to Liquid Nitrogen Cooling |
| Detector Type [Parameter Image 03; Liquid-Nitrogen-Cooled SymphonyII Detector; Independent Description of Compatible CCDs] | Silicon, InGaAs and Extended InGaAs |
| Spectral Range [Parameter Image 03; Liquid-Nitrogen-Cooled SymphonyII Detector; Independent Description of Compatible CCDs] | 200nm~2.2μm |
| Focal Length [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item] | 320 mm |
| Relative Aperture [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item] | f/4.1 |
| Spectral Range [Parameter Figure 02 Basic Technical Specifications; All Parameters Based on a 1200g/mm Grating at 435nm, except Items Explicitly Specifying Another Wavelength; Using a 1200g/mm Grating] | 150~1500 nm |
| Maximum Spectral Coverage [Parameter Figure 02 Basic Technical Specifications; All Parameters Based on a 1200g/mm Grating at 435nm, except Items Explicitly Specifying Another Wavelength; Using Another Suitable Grating Specification] | 150nm~40μm |
| Grating Dimensions [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item] | 68 mm × 68 mm |
| Number of Gratings on the Turret [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item] | Up to 3 |
| Focal-Plane (Flat-Field) Dimensions [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item] | 30 mm × 12 mm |
| Resolution [Parameter Figure 02 Basic Technical Specifications; All Parameters Based on a 1200g/mm Grating at 435nm, except Items Explicitly Specifying Another Wavelength; Slit/PMT] | 0.06 nm |
| Wavelength Accuracy [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item] | ±0.20 nm |
| Repeatability [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item] | ±0.075 nm |
| Spectral Dispersion [Parameter Figure 02 Basic Technical Specifications; All Parameters Based on a 1200g/mm Grating at 435nm, except Items Explicitly Specifying Another Wavelength; This Item Explicitly Specifies @500nm] | 2.31 nm/mm |
| Magnification [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item] | 1.1 |
| Stray Light [Parameter Figure 02*; Using a HORIBA Scientific Holographic Grating, Measured 1nm from the Peak Baseline of the 514nm Laser Line] | 1.5×10⁻⁴ |
| Scanning Speed [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item] | 160 nm/s |
| Step Size [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item] | 0.002 nm |
| Computer Interface [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item] | High-Speed USB |
| Length [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item; Independent Technical Table Dimensions] | 417 mm |
| Width [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item; Independent Technical Table Dimensions] | 422 mm |
| Height [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item; Independent Technical Table Dimensions] | 192 mm |
| Optical-Axis Height [Parameter Figure 02 Basic Technical Specifications; All Parameters Based on a 1200g/mm Grating at 435nm, except Items Explicitly Specifying Another Wavelength; Measured from Instrument Bottom] | 98 mm |
| Weight [Parameter Image 02 Basic Technical Specifications; All Parameters Given for a 1200g/mm Grating at 435nm, Except Where a Wavelength Is Explicitly Stated for the Item] | 20 kg |
| Groove Density | 3600 g/mm |
| Linear Dispersion | 0.20 nm/mm |
| Grating-Turret Mechanical Range | 0~500 nm |
| Spectral Range per Acquisition | 5 nm |
| Spectral Range per Pixel | 0.003 nm |
| Typical Spectral Resolution | 0.01 nm |
| Spectral Range per Pixel | 0.005 nm |
| Typical Spectral Resolution | 0.02 nm |
| Groove Density | 2400 g/mm |
| Linear Dispersion | 0.87 nm/mm |
| Grating-Turret Mechanical Range | 0~750 nm |
| Spectral Range per Acquisition | 23 nm |
| Spectral Range per Pixel | 0.012 nm |
| Typical Spectral Resolution | 0.04 nm |
| Spectral Range per Pixel | 0.023 nm |
| Typical Spectral Resolution | 0.07 nm |
| Groove Density | 1800 g/mm |
| Linear Dispersion | 1.38 nm/mm |
| Grating-Turret Mechanical Range | 0~1000 nm |
| Spectral Range per Acquisition | 37 nm |
| Spectral Range per Pixel | 0.019 nm |
| Typical Spectral Resolution | 0.06 nm |
| Spectral Range per Pixel | 0.036 nm |
| Typical Spectral Resolution | 0.11 nm |
| Groove Density | 1200 g/mm |
| Linear Dispersion | 2.31 nm/mm |
| Grating-Turret Mechanical Range | 0~1500 nm |
| Spectral Range per Acquisition | 62 nm |
| Spectral Range per Pixel | 0.031 nm |
| Typical Spectral Resolution | 0.09 nm |
| Spectral Range per Pixel | 0.060 nm |
| Typical Spectral Resolution | 0.18 nm |
| Groove Density | 900 g/mm |
| Linear Dispersion | 3.20 nm/mm |
| Grating-Turret Mechanical Range | 0~2000 nm |
| Spectral Range per Acquisition | 85 nm |
| Spectral Range per Pixel | 0.043 nm |
| Typical Spectral Resolution | 0.13 nm |
| Spectral Range per Pixel | 0.083 nm |
| Typical Spectral Resolution | 0.25 nm |
| Groove Density | 600 g/mm |
| Linear Dispersion | 4.94 nm/mm |
| Grating-Turret Mechanical Range | 0~3000 nm |
| Spectral Range per Acquisition | 132 nm |
| Spectral Range per Pixel | 0.067 nm |
| Typical Spectral Resolution | 0.20 nm |
| Spectral Range per Pixel | 0.128 nm |
| Typical Spectral Resolution | 0.39 nm |
| Groove Density | 300 g/mm |
| Linear Dispersion | 10.12 nm/mm |
| Grating-Turret Mechanical Range | 0~6000 nm |
| Spectral Range per Acquisition | 270 nm |
| Spectral Range per Pixel | 0.137 nm |
| Typical Spectral Resolution | 0.41 nm |
| Spectral Range per Pixel | 0.263 nm |
| Typical Spectral Resolution | 0.79 nm |
| Groove Density | 150 g/mm |
| Linear Dispersion | 20.43 nm/mm |
| Grating-Turret Mechanical Range | 0~12000 nm |
| Spectral Range per Acquisition | 545 nm |
| Spectral Range per Pixel | 0.276 nm |
| Typical Spectral Resolution | 0.83 nm |
| Spectral Range per Pixel | 0.531 nm |
| Typical Spectral Resolution | 1.59 nm |
Key Features
iHR Means Imaging High Resolution,Excellent Imaging/Spectral Resolution;Unique Asymmetric Czerny-Turner rather than Common Rectangular Symmetric Path,Optimizes Imaging,Eliminates Secondary Diffraction,Maximizes Throughput;Re-Diffracted Light Returning to Grating Causes Dim Background/Baseline Rise/Lower Sensitivity across Bands,Especially Symmetric Designs;Computer-Simulated Optimized Optic Positions Precisely Eliminate It;With CCD,Toroidal Mirrors Correct Astigmatism,Tangential Resolution/Sagittal Imaging Optimization,Adjustable CCD Prioritizes Imaging or Resolution;Asymmetric Path/On-Axis Grating Scan Reduces Coma/Other Aberrations for Wider Flat Field;Toroidal Focus Mirror Larger than Collimator Avoids Edge Throughput Loss/Vignetting;Standard/Custom Single/Dual Inputs/Outputs,Grating Turret,Single/Multichannel Detectors,Sample Chamber,Fiber/Adapters,Filters,Shutters,CCD Flanges;SynerJY®,Labspec Raman,SDK,LabVIEW VIs;Seamless One-Piece Casting for Strength/Thermal Stability,Optical Chamber Separate from Electronics,Strict Aging Cycles/Repeated Drive Tests;Synapse™/Symphony®/Syncerity™ CCDs,Front/Open-Electrode through Back/Deep-Depletion by Experiment
Datasheet
Please provide your email to download the datasheet.
Your name
Email Address
Invalid email format. Please try again.
Send Request
Supplier Information
Starting from basic and simple optical spectroscopy and imaging modules to multi-functional and complex spectroscopy and imaging system solutions, Dowell Photonics has been committed to providing customized, personalized services and experiences. With exquisite technology, we design clever and flexible optical modules, making your experimental testing, R&D, and production no longer limited by instrument functions. We help you build, expand, and upgrade multi-functional spectroscopic testing systems to meet your special needs!
Contact Us
Loading...
GetExperimental Plan
Name
Phone
+86
Organization
Use Case

Global Photonics Products
Database Platform
Database Platform
With 16 years of experience, we provide high-quality products and services to universities, research institutes, and industry.
50+ Detailed Categories · 3,000+ Global Brands · 100,000+ Photonics Products
1 Million+
In-depth analysis of professional academic resources in photonics
300,000
ProductsDatasheets Available Free
We will keep your personal information strictly confidential.
Product Quote
+86
* Select the quoting party:
By submitting, you agree to the User Service Agreement and Privacy Policy