Ultrafast Laser Scanning Galvanometer System Fsscan-ultra
Fsscan-ultra is a general-purpose two-axis ultrafast-laser galvanometer control system for high-speed, accurate motor operation. Integrated power/control/drive ensures long-term reliability, with convenient host connection over USB. Designed for industrial marking, precision machining and scanning, moving-magnet motors, precision servos, professional control cards and fast interfaces accurately steer/position beams across laser wavelengths and material/accuracy needs. Uses include ultrafast micro/nanofabrication, precision cold marking, ultrafast microscopy and medical lasers. Step response is 0.3–0.5ms at 1% full scale and marking speed 2–3m/s. High repeatability, stated tracking error down to 0.12ms and low long-term drift maintain consistency. Clear apertures of 10/14mm suit medium/high-power delivery while avoiding beam-energy loss.
Overview
Specifications
| Parameter | Value |
|---|---|
| Aperture [Configuration column 1 of the galvanometer-scanner parameter table on page 2; aperture 10mm; interface SL2-100/XY2-100; no model name specified in the original table] | 10 mm |
| Tracking Error [Configuration column 1 of the galvanometer-scanner parameter table on page 2; aperture 10mm; interface SL2-100/XY2-100; no model name specified in the original table] | 0.12 ms |
| Marking Speed [Configuration column 1 of the galvanometer-scanner parameter table on page 2; aperture 10mm; interface SL2-100/XY2-100; no model name specified in the original table] | 3.0 m/s |
| Step Response Time [Configuration column 1 of the galvanometer-scanner parameter table on page 2; aperture 10mm; interface SL2-100/XY2-100; no model name specified in the original table; 1% of full scale] | 0.3 ms |
| Step Response Time [Configuration column 1 of the galvanometer-scanner parameter table on page 2; aperture 10mm; interface SL2-100/XY2-100; no model name specified in the original table; 10% of full scale] | 0.8 ms |
| Repeatability [Configuration column 1 of the galvanometer-scanner parameter table on page 2; aperture 10mm; interface SL2-100/XY2-100; no model name specified in the original table] | <2 μrad |
| Interface Protocol [Configuration column 1 of the galvanometer-scanner parameter table on page 2; aperture 10mm; interface SL2-100/XY2-100; no model name specified in the original table] | SL2-100/XY2-100 |
| Aperture [Configuration column 2 of the galvanometer-scanner parameter table on page 2; aperture 14mm; interface SL2-100/XY2-100; no model name specified in the original table] | 14 mm |
| Tracking Error [Configuration column 2 of the galvanometer-scanner parameter table on page 2; aperture 14mm; interface SL2-100/XY2-100; no model name specified in the original table] | 0.15 ms |
| Marking Speed [Configuration column 2 of the galvanometer-scanner parameter table on page 2; aperture 14mm; interface SL2-100/XY2-100; no model name specified in the original table] | 2.0 m/s |
| Step Response Time [Configuration column 2 of the galvanometer-scanner parameter table on page 2; aperture 14mm; interface SL2-100/XY2-100; no model name specified in the original table; 1% of full scale] | 0.35 ms |
| Step Response Time [Configuration column 2 of the galvanometer-scanner parameter table on page 2; aperture 14mm; interface SL2-100/XY2-100; no model name specified in the original table; 10% of full scale] | 0.9 ms |
| Repeatability [Configuration column 2 of the galvanometer-scanner parameter table on page 2; aperture 14mm; interface SL2-100/XY2-100; no model name specified in the original table] | <2 μrad |
| Interface Protocol [Configuration column 2 of the galvanometer-scanner parameter table on page 2; aperture 14mm; interface SL2-100/XY2-100; no model name specified in the original table] | SL2-100/XY2-100 |
| Aperture [Configuration column 3 of the galvanometer-scanner parameter table on page 2; aperture 10mm; interface XY2-100/RL2-100; no model name specified in the original table] | 10 mm |
| Tracking Error [Configuration column 3 of the galvanometer-scanner parameter table on page 2; aperture 10mm; interface XY2-100/RL2-100; no model name specified in the original table] | 0.13 ms |
| Marking Speed [Configuration column 3 of the galvanometer-scanner parameter table on page 2; aperture 10mm; interface XY2-100/RL2-100; no model name specified in the original table] | 2.5 m/s |
| Step Response Time [Configuration column 3 of the galvanometer-scanner parameter table on page 2; aperture 10mm; interface XY2-100/RL2-100; no model name specified in the original table; 1% of full scale] | 0.3 ms |
| Step Response Time [Configuration column 3 of the galvanometer-scanner parameter table on page 2; aperture 10mm; interface XY2-100/RL2-100; no model name specified in the original table; 10% of full scale] | 0.8 ms |
| Repeatability [Configuration column 3 of the galvanometer-scanner parameter table on page 2; aperture 10mm; interface XY2-100/RL2-100; no model name specified in the original table] | <15 μrad |
| Interface Protocol [Configuration column 3 of the galvanometer-scanner parameter table on page 2; aperture 10mm; interface XY2-100/RL2-100; no model name specified in the original table] | XY2-100/RL2-100 |
| Aperture [Configuration column 4 of the galvanometer-scanner parameter table on page 2; aperture 14mm; interface XY2-100/RL2-100; no model name specified in the original table] | 14 mm |
| Tracking Error [Configuration column 4 of the galvanometer-scanner parameter table on page 2; aperture 14mm; interface XY2-100/RL2-100; no model name specified in the original table] | 0.19 ms |
| Marking Speed [Configuration column 4 of the galvanometer-scanner parameter table on page 2; aperture 14mm; interface XY2-100/RL2-100; no model name specified in the original table] | 2 m/s |
| Step Response Time [Configuration column 4 of the galvanometer-scanner parameter table on page 2; aperture 14mm; interface XY2-100/RL2-100; no model name specified in the original table; 1% of full scale] | 0.5 ms |
| Step Response Time [Configuration column 4 of the galvanometer-scanner parameter table on page 2; aperture 14mm; interface XY2-100/RL2-100; no model name specified in the original table; 10% of full scale] | 1 ms |
| Repeatability [Configuration column 4 of the galvanometer-scanner parameter table on page 2; aperture 14mm; interface XY2-100/RL2-100; no model name specified in the original table] | <15 μrad |
| Interface Protocol [Configuration column 4 of the galvanometer-scanner parameter table on page 2; aperture 14mm; interface XY2-100/RL2-100; no model name specified in the original table] | XY2-100/RL2-100 |
| Scan Angle [All Scanning Galvanometer Configurations; Common Value Spanning Four Columns] | ±0.35 rad |
| Operating Temperature [All Scanning Galvanometer Configurations; Common Value Spanning Four Columns] | 25±10 |
| Controller Dimensions [Controller Parameter Table] | 324.5 mm × 482 mm × 96.5 mm |
| Power Input [Controller Parameter Table] | AC220V 2A |
| Galvanometer Power-Supply Output [Controller Parameter Table] | ±15V 3A |
| General-Purpose I/O Input [Controller Parameter Table] | 2 complete plans |
| General-Purpose I/O Output [Controller Parameter Table] | 2 complete plans |
| Communication Interface [Controller Parameter Table] | USB type-B |
Applications
Key Features
Datasheet
Supplier Information