BIM-6703 series high-sensitivity spectrometers NIR BIM-6703-02

BIM-6703 series high-sensitivity spectrometers NIR BIM-6703-02

Supplier
Brolight
Part Number
BIM-6703-02
Category
Spectrometers
Origin
China

The BIM-6703 series high-sensitivity spectrometer uses an area-array back-illuminated CCD and optimized optics to greatly improve sensitivity, especially over 800nm-1100nm, making it well suited to Raman and other weak near-infrared spectra. The detector responds over 200nm-1100nm. Different slits, gratings, and other components within that range allow customized wavelength ranges and optical resolutions. Multiple trigger modes, secondary-development support, and comprehensive in-depth customization are also available.

Specification Snapshot
Dimensions [BIM-6703: Parameter Specifications]
165 mm × 110 mm × 38 mm
Weight [BIM-6703: Parameter Specifications]
0.7 Kg
Wavelength Range
750-1100 nm
Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

The BIM-6703 series high-sensitivity spectrometer uses an area-array back-illuminated CCD and optimized optics to greatly improve sensitivity, especially over 800nm-1100nm, making it well suited to Raman and other weak near-infrared spectra. The detector responds over 200nm-1100nm. Different slits, gratings, and other components within that range allow customized wavelength ranges and optical resolutions. Multiple trigger modes, secondary-development support, and comprehensive in-depth customization are also available.

Specifications

ParameterValue
Detector wavelength range [BIM-6703: Parameter Specifications]200nm-1100nm
Detector-sensitive spectral band [BIM-6703: Parameter Specifications]500nm-1100nm
Fiber Connectors [BIM-6703: Parameter Specifications]SMA905
Detector [BIM-6703: Parameter Specifications]Hamamatsu S16010 series area-array back-illuminated CCD
Detector Pixel [BIM-6703: Parameter Specifications]2048×64 pixels, pixel size 14μm×14μm
Signal-to-Noise Ratio [BIM-6703: Parameter Specifications]800:1
A/D Resolution [BIM-6703: Parameter Specifications]16 bit
Integration Time [BIM-6703: Parameter Specifications]1ms-10s
Dynamic Range [BIM-6703: Parameter Specifications]typical:50000:1 (typical value)
Trigger Mode [BIM-6703: Parameter Specifications]Normal Mode, Software Trigger, Hardware Trigger, Synchronous Trigger
Power Dissipation [BIM-6703: Parameter Specifications]5VDC,500mA
Ambient Temperature (Recommended Temperature) [BIM-6703: Parameter Specifications; Recommended Temperature 25℃]5℃-35℃ (Recommended Temperature 25℃)
Communication Interface [BIM-6703: Parameter Specifications]USB2.0,RS232
Operating System [BIM-6703: Parameter Specifications]Win XP,Win7,Win8,Win10
Power Supply Method [BIM-6703: Parameter Specifications]USB
Dimensions [BIM-6703: Parameter Specifications]165 mm × 110 mm × 38 mm
Weight [BIM-6703: Parameter Specifications]0.7 Kg
Wavelength Range750-1100 nm

Applications

Raman and fluorescence spectroscopy; weak near-infrared and ultraviolet spectroscopy; transmittance, absorbance, and reflectance measurements of weak spectra.

Key Features

Signal-to-noise ratio: 800:1. Dynamic range: 50000:1, typical. Detector: Hamamatsu area-array back-illuminated CCD. Automatic calculations: Peak-wavelength and bandwidth detection. Compact palm-sized design for easy operation. Optics: Crossed asymmetric C-T configuration with an interference filter suppressing second-order diffraction. Connections: SMA905 fiber connector, USB 2.0 data transfer and power. Flexible configuration: Selectable wavelength ranges and optical resolutions. Communication: RS232 interface. Triggering: Multiple modes. Customization: SDK for secondary development and OEM integration.

Datasheet

Product Datasheet
PDF
Download

Supplier Information

Br
Brolight
View Supplier →
Brolight, as an independent brand under A&P Instrument, focuses on the R&D, manufacturing, and integrated solution delivery of photoelectric detection equipment and educational instruments. Leveraging A&P Instrument's over 40 years of technical accumulation and market experience in the optoelectronics and science education industry, Brolight precisely meets the multiple needs of scientific research, industrial inspection, and experimental teaching, building a reliable and efficient application foundation for global research institutions, industrial enterprises, and educational users with excellent optoelectronic products and teaching instruments. Founded in 2012, the company is a national high-tech enterprise and has passed ISO9001:2015 quality management system certification, ensuring continuous and stable product quality with a standardized management system.

Request a Quote

Our team responds within 24–48 hours
BIM-6703 series high-sensitivity spectrometers NIR BIM-6703-02
Brolight · Spectrometers
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →