FlexiSpec® The product line includes the newest generation. Single Channel and Dual Channel It's... Optical Fiber The probe is compatible. Spectrometer And the light machine. 。 Single Channel and Dual Channel It's... Optical Fiber The probes are compatible with all self-cleaning processes. Interface , Real-time monitoring laboratory , Experimental plant and fully automated process control 。 Product application Product characteristics Figure
Specification Snapshot
Optical Fiber Type [Type of probe = Transmittance ; Transfer Range =0,2 – 1,3 μm]
Silica UV-Vis
Optical Fiber Type [Type of probe = Transmittance ; Transfer Range =0,4 – 2,2 μm]
Silica Vis-NIR
Optical Fiber Type [Type of probe = Half Transflectance Pattern ; Transfer Range =0,2 -1,3μm]
Silica UV-Vis
Optical Fiber Type [Type of probe = Half Transflectance Pattern ; Transfer Range =0,4 – 2,2 μm]
Silica Vis-NIR
Optical Fiber Type [Type of probe = Half Transflectance Pattern ; Transfer Range =1,6 – 5,5 μm]
CIR
Request a Quote
Download Datasheet
Overview
FlexiSpec® The product line includes the newest generation. Single Channel and Dual Channel It's... Optical Fiber The probe is compatible. Spectrometer And the light machine. 。 Single Channel and Dual Channel It's... Optical Fiber The probes are compatible with all self-cleaning processes. Interface , Real-time monitoring laboratory , Experimental plant and fully automated process control 。 Product application Product characteristics Figure
Specifications
| Parameter | Value |
|---|---|
| Transfer Range [Type of probe = Transmittance ; Transfer Range =0,2 – 1,3 μm] | 0,2 – 1,3 μm |
| Transfer Range [Type of probe = Transmittance ; Transfer Range =0,4 – 2,2 μm] | 0,4 – 2,2 μm |
| Transfer Range [Type of probe = Half Transflectance Pattern ; Transfer Range =0,2 -1,3μm] | 0,2 -1,3μm |
| Transfer Range [Type of probe = Half Transflectance Pattern ; Transfer Range =0,4 – 2,2 μm] | 0,4 – 2,2 μm |
| Transfer Range [Type of probe = Half Transflectance Pattern ; Transfer Range =1,6 – 5,5 μm] | 1,6 – 5,5 μm |
| Optical Fiber Type [Type of probe = Transmittance ; Transfer Range =0,2 – 1,3 μm] | Silica UV-Vis |
| Optical Fiber Type [Type of probe = Transmittance ; Transfer Range =0,4 – 2,2 μm] | Silica Vis-NIR |
| Optical Fiber Type [Type of probe = Half Transflectance Pattern ; Transfer Range =0,2 -1,3μm] | Silica UV-Vis |
| Optical Fiber Type [Type of probe = Half Transflectance Pattern ; Transfer Range =0,4 – 2,2 μm] | Silica Vis-NIR |
| Optical Fiber Type [Type of probe = Half Transflectance Pattern ; Transfer Range =1,6 – 5,5 μm] | CIR |
| Gap diameter [Type of probe = Transmittance ; Transfer Range =0,2 – 1,3 μm] | 2; 5; 10; 20 mm |
| Gap diameter [Type of probe = Transmittance ; Transfer Range =0,4 – 2,2 μm] | 2; 5; 10 mm |
| Gap diameter [Type of probe = Half Transflectance Pattern ; Transfer Range =0,2 -1,3μm] | 2; 5; 10; 20 mm |
| Gap diameter [Type of probe = Half Transflectance Pattern ; Transfer Range =0,4 – 2,2 μm] | 2; 5; 10 mm |
| Gap diameter [Type of probe = Half Transflectance Pattern ; Transfer Range =1,6 – 5,5 μm] | 0.05 – 2.0 mm |
| Temperature range [Type of probe = Transmittance ; Transfer Range =0,2 – 1,3 μm] | ≤ 200°C |
| Temperature range [Type of probe = Transmittance ; Transfer Range =0,4 – 2,2 μm] | ≤ 200°C |
| Temperature range [Type of probe = Half Transflectance Pattern ; Transfer Range =0,2 -1,3μm] | ≤ 200°C |
| Temperature range [Type of probe = Half Transflectance Pattern ; Transfer Range =0,4 – 2,2 μm] | ≤ 200°C |
| Temperature range [Type of probe = Half Transflectance Pattern ; Transfer Range =1,6 – 5,5 μm] | ≤ 100°C |
| Minimum Bend Radius [Type of probe = Transmittance ; Transfer Range =0,2 – 1,3 μm] | 120 mm |
| Minimum Bend Radius [Type of probe = Transmittance ; Transfer Range =0,4 – 2,2 μm] | 120 mm |
| Minimum Bend Radius [Type of probe = Half Transflectance Pattern ; Transfer Range =0,2 -1,3μm] | 120 mm |
| Minimum Bend Radius [Type of probe = Half Transflectance Pattern ; Transfer Range =0,4 – 2,2 μm] | 120 mm |
| Minimum Bend Radius [Type of probe = Half Transflectance Pattern ; Transfer Range =1,6 – 5,5 μm] | 130 mm |
| Overall Length [Type of probe = Transmittance ; Transfer Range =0,4 – 2,2 μm] | 1,5 m ( Other Options : 1 – 30m) * |
| Overall Length [Type of probe = Half Transflectance Pattern ; Transfer Range =0,2 -1,3μm] | 1,5 m ( Other Options : 1 – 30m) * |
| Overall Length [Type of probe = Half Transflectance Pattern ; Transfer Range =0,4 – 2,2 μm] | 1,5 m ( Other Options : 1 – 30m) * |
| Overall Length [Type of probe = Half Transflectance Pattern ; Transfer Range =1,6 – 5,5 μm] | 1,5 m ( Other Options : 1 – 30m) * |
| Axis Length [Type of probe = Transmittance ; Transfer Range =0,4 – 2,2 μm] | 230mm ( Other Options : 50 – 500mm) * |
| Axis Length [Type of probe = Half Transflectance Pattern ; Transfer Range =0,2 -1,3μm] | 230mm ( Other Options : 50 – 500mm) * |
| Axis Length [Type of probe = Half Transflectance Pattern ; Transfer Range =0,4 – 2,2 μm] | 230mm ( Other Options : 50 – 500mm) * |
| Axis Length [Type of probe = Half Transflectance Pattern ; Transfer Range =1,6 – 5,5 μm] | 230mm ( Other Options : 50 – 500mm) * |
| Axis diameter [Type of probe = Transmittance ; Transfer Range =0,4 – 2,2 μm] | 12mm |
| Axis diameter [Type of probe = Half Transflectance Pattern ; Transfer Range =0,2 -1,3μm] | 12mm |
| Axis diameter [Type of probe = Half Transflectance Pattern ; Transfer Range =0,4 – 2,2 μm] | 12mm |
| Axis diameter [Type of probe = Half Transflectance Pattern ; Transfer Range =1,6 – 5,5 μm] | 12mm |
| Axis Material [Type of probe = Transmittance ; Transfer Range =0,4 – 2,2 μm] | SS, Hastelloy C22 |
| Axis Material [Type of probe = Half Transflectance Pattern ; Transfer Range =0,2 -1,3μm] | SS, Hastelloy C22 |
| Axis Material [Type of probe = Half Transflectance Pattern ; Transfer Range =0,4 – 2,2 μm] | SS, Hastelloy C22 |
| Axis Material [Type of probe = Half Transflectance Pattern ; Transfer Range =1,6 – 5,5 μm] | SS, Hastelloy C22 |
| The protection tube. Material [Type of probe = Transmittance ; Transfer Range =0,4 – 2,2 μm] | It's not liquid. SS- A conduit. , KOPEX- Pipe |
| The protection tube. Material [Type of probe = Half Transflectance Pattern ; Transfer Range =0,2 -1,3μm] | It's not liquid. SS- A conduit. , KOPEX- Pipe |
| The protection tube. Material [Type of probe = Half Transflectance Pattern ; Transfer Range =0,4 – 2,2 μm] | It's not liquid. SS- A conduit. , KOPEX- Pipe |
| The protection tube. Material [Type of probe = Half Transflectance Pattern ; Transfer Range =1,6 – 5,5 μm] | It's not liquid. SS- A conduit. , KOPEX- Pipe |
| Input / Output Connector [Type of probe = Transmittance ; Transfer Range =0,4 – 2,2 μm] | Long SMA; FC/PC; ST |
| Input / Output Connector [Type of probe = Half Transflectance Pattern ; Transfer Range =0,2 -1,3μm] | Long SMA; FC/PC; ST |
| Input / Output Connector [Type of probe = Half Transflectance Pattern ; Transfer Range =0,4 – 2,2 μm] | Long SMA; FC/PC; ST |
| Input / Output Connector [Type of probe = Half Transflectance Pattern ; Transfer Range =1,6 – 5,5 μm] | Long SMA; FC/PC; ST |
| Compatibility process Interface [Type of probe = Transmittance ; Transfer Range =0,4 – 2,2 μm] | Ceramat-FOS or SensoGate-FOS |
| Compatibility process Interface [Type of probe = Half Transflectance Pattern ; Transfer Range =0,2 -1,3μm] | Ceramat-FOS or SensoGate-FOS |
| Compatibility process Interface [Type of probe = Half Transflectance Pattern ; Transfer Range =0,4 – 2,2 μm] | Ceramat-FOS or SensoGate-FOS |
| Compatibility process Interface [Type of probe = Half Transflectance Pattern ; Transfer Range =1,6 – 5,5 μm] | Ceramat-FOS or SensoGate-FOS |
Applications
Real-time response monitoring / Experimental online analysis (PAT)/ Monitoring of the crystal process / Characteristic Analysis / Biopharmaceutical analysis / Biofuels development and production
Key Features
* Transmitting online spectrums at long distances in liquid ; * Ultraviolet 、 See to Medium Infrared Spectroscopy Transmittance High ; * Stable industrial environment ; * Use Spectrometer / Automation control Interface Compatibility
Datasheet
Please provide your email to download the datasheet.
Your name
Email Address
Invalid email format. Please try again.
Send Request
Supplier Information
Shenzhen Uniqueray Technology Co., Ltd. is a national-level high-tech enterprise and a well-known supplier of optoelectronic products and solutions in China. Our team has many years of experience in the optoelectronic industry and has long provided high-quality products and solutions to universities, research institutes, aerospace and military, and enterprise customers, promoting the upgrading and internationalization of China's optoelectronic industry.
Uniqueray has always focused on cutting-edge optoelectronic technologies. Our products and services cover: DFB / ICL / QCL lasers, HgCdTe MCT / InAs / InAsSb detectors, balanced detectors, single-photon detectors/counting modules, femtosecond lasers, mid-infrared LEDs, III-V epitaxial wafers, high-temperature copper/gold-coated fibers, mid-infrared fibers and fiber probes, laser drivers and temperature control modules, quantum system control (MOT), integrated TDLAS and photoacoustic spectroscopy solutions, and the C14-SCAR radiocarbon analyzer based on saturated absorption cavity ring-down CRDS. Products are mainly used in: high-sensitivity laser gas analysis, infrared detection, fiber spectroscopy, healthcare, ultrafast spectroscopy, quantum technology, laser processing, aerospace and military, scientific research and other fields.
Our vision: to become a first-class supplier of optoelectronic products and solutions.
Contact Us
Loading...
GetExperimental Plan
Name
Phone
+86
Organization
Use Case

Global Photonics Products
Database Platform
Database Platform
With 16 years of experience, we provide high-quality products and services to universities, research institutes, and industry.
50+ Detailed Categories · 3,000+ Global Brands · 100,000+ Photonics Products
1 Million+
In-depth analysis of professional academic resources in photonics
300,000
ProductsDatasheets Available Free
We will keep your personal information strictly confidential.
Product Quote
+86
* Select the quoting party:
By submitting, you agree to the User Service Agreement and Privacy Policy