TD500 Series Large Screen Temperature Monitor
TD500 Series Large Screen Temperature Monitor is An intelligent temperature monitor , is Infrared Pyrometer or other instrument of the detector 。 Use a little red LED Scan Show , Compared to normal , It's a lot less. 。 The pixels displayed are precise to 3 Pixels , Even a few damagees don't affect the whole display. 。 It can hang on the wall. ,50 Mine's clear. , Show Intuitive 、 Easy. 。 It can modify the meter's range settings at all times. , Signal processing has peaks. 、 Valley 、 Average 。 And according to user needs , Average temperature retained for a period of time , Automatically update the next temperature when it arrives 。 Self-check and precision correction with instrument 。
Overview
Specifications
| Parameter | Value |
|---|---|
| Work Power Supply | AC220(1±20%)V, - Yeah. EMI Filter |
| Enter the signal. | 4mA~20mA, Sampling electrical resistance 100 Orm. , With pressure protection. , Passage protection |
| Measuring precision [tm For the upper limit of the temperature range] | ±0.2%tm℃(tm For the upper limit of the temperature range ) |
| Repeatability | ±1℃ |
| Response Time | 10ms |
| The upper limit corresponds to the temperature. | Set range to -50℃~3200℃, Upper limit temperature and 20mA Corresponding |
| Lower limit corresponds to temperature | Set range to -50℃~3200℃, Lower limit temperature and 4mA Corresponding |
| Measurement Mode | Real time temperature : Set Time 0.0s, Response time is 10ms Peak temperature : Set Time 0s~99.9s,>99.0s Yes None Keep limit 。 Valley temperature : Set Time 0s~99.9s,>99.0s Yes None Keep limit 。 Mean temperature : Set Time 0s~60.0s, Average response time To signal up 95% Time used , First step RC Algorithm 。 |
| Correction factor | Set Range 990~1010, No correction time factor is required 1000 |
| Mean Trigger | Optional Select to open or close , Maximum and lower limit values for trigger temperature can be set 。 Trigger upper and lower limit temperatures , Set range to -50℃~3000℃。 Automatically maintain the average temperature of the previous target 。 |
| Show Self-School Functions | Show “88.88℃”, For LED Optical tube test 。 |
| Power protection. | When the power went off , Retain the values of the parameters set |
| Alarm function | We can set up a cap on the alarm. Threshold , Lower limit to call the police. Threshold 。 And there's a relay output. , Node Capacity 5A/250VAC |
| Use Environment | Temperature of the environment :-10℃~60℃, Relative humidity :10~95%, None Show |
| Power Dissipation | No alarm. :6W(LED Full light ) Bring the alarm. :16W(LED All bright and simultaneous alarms. ), The alarm is the selected package |
| Overall Dimensions | Long wide high (500mm*168mm*65mm) |